Tender For Solar Light, 6 Mtr Ht Eachwith Single Panel 12 W Bulb With 12.8 V Lithium Ferro Inbuilt Battery, 75 Wp, 30Ah I) At Garapota Paschimpara Bazar More, Booth No. 249, Gazna Gp, Hanskhali Block (02 Pcs) Ii) At Booth No. 134, Dakshinpara-Ii Gp,, Nadia-West Bengal
TDR : 55827315
Tender Notice
BOQ
16 Days Left
Nadia
West Bengal
Tender For Solar Light, 6 Mtr Ht Eachwith Single Panel 12 W Bulb With 12.8 V Lithium Ferro Inbuilt Battery, 75 Wp, 30Ah I) At Garapota Paschimpara Bazar More, Booth No. 249, Gazna Gp, Hanskhali Block (02 Pcs) Ii) At Booth No. 134, Dakshinpara-Ii Gp,
Name of Work:- Solar light, 6 Mtr HT eachwith single panel 12 W bulb with 12.8 V Lithium ferro inbuilt battery, 75 Wp, 30Ah i) At Garapota paschimpara Bazar more, Booth no. 249, Gazna GP, Hanskhali Block (02 Pcs) ii) At booth no. 134, Dakshinpara-II GP, Hanskhali block(02 Pcs), iii) At booth no. 135, Dakshinpara-II GP, Hanskhali block(02 Pcs), iv) At booth no. 136, Dakshinpara-II GP, Hanskhali block(02 Pcs), v) At booth no. 137, Dakshinpara-II GP, Hanskhali block(02 Pcs), vi) At booth no. 138, Dakshinpara-II GP, Hanskhali block (02 Pcs), vii) At booth no. 139, Dakshinpara-II GP, Hanskhali block(02 Pcs), viii) At booth no. 140, Dakshinpara-II GP, Hanskhali block (02 Pcs), ix) At booth no. 141, Dakshinpara-II GP, Hanskhali block(02 Pcs), x) At booth no. 142, Dakshinpara-II GP, Hanskhali block (02 Pcs) , xi)At booth no. 143, Dakshinpara-II GP, Hanskhali block(02 Pcs), xii) At booth no. 144, Dakshinpara-II GP, Hanskhali block(02 Pcs), xiii) At booth no. 145, Dakshinpara-II GP, Hanskhali block(02 Pcs), xiv) At booth no. 146, Dakshinpara-II GP, Hanskhali block(02 Pcs), xv)At booth no. 147, Dakshinpara-II GP, Hanskhali block (02 Pcs), xvi) At booth no. 148, Dakshinpara-II GP, Hanskhali block (02 Pcs), xvii) At booth no. 149, Dakshinpara-II GP, Hanskhali block (02 Pcs), xviii) At booth no. 150, Dakshinpara-1 GP, Hanskhali block (02 Pcs), xix) At booth no. 151, Dakshinpara-1 GP. Hanskhall block(02 Pcs), xx) At booth no. 152, Dakshinpara-I GP, Hanskhali block(02 Pcs), xxi) At booth no. 153, Dakshinpara-I GP. Hanskhali block(02 Pcs), xxii) At booth no. 154, Dakshinpara-I GP, Hanskhali block(02 Pcs), xxiii) At booth no. 155, Dakshinpara-I GP. Hanskhali block (02 Pcs), xxiv) At booth no. 156. Dakshinpara-I GP, Hanskhali block(02 Pcs), xxv) At booth no. 157, Dakshinpara-I GP, Hanskhali block(02 Pcs), xxvi) At booth no. 158, Dakshinpara-1 GP,Hanskhali block (02 Pcs), xxvii) At booth no. 159, Dakshinpara-I GP, Hanskhali block(02 Pcs), xxviii) At booth no. 160, Dakshinpara-I GP, Hanskhali block(02 Pcs), xxix) At Gournagar, booth no. 217, Mayurhat-I GP, Hanskhali block (03 Pcs) xxx) At near Gholarpara Satsangha mandir Baroary math, Booth no-151, Betna Gobindapur GP, Hanskhali block (02Pcs) in the Nadia District. (Total= 61 Pcs)
Sl. No.
Item Description
1
Module-75 WP (ERTL and Flash Tested) (Supply & Erection) of Modular Panel. Supplying and Supply of 75wp Poly/ Mono crystaline module with IEC 61215, TEC6173-1,2 compliance withmust have a certificate of testing conforming to IEC 61215I. The PV module shall contain crystalline silicon solar cells and EditionII. The power output of the module(s) under STC would be a of 75 Wp at a load voltage* of 16.4±0.2 V minimumIII. The open a circuit voltage* of the PV modules under STC would be 21.0 VoltsIV. The module efficiency would be 14.5%V.SPV module shall be highly reliable, lightweight and shall have a service life of more than 25 years. SPV modules shall have the end of 10 years and not more than 20% at the end of 25 yearsVII. The solar module shall be able to withstand the following environmental conditions normally encountered at site - Temp. extremes ranging from -100 C to +850 C Wind load 150 km/h Maximum mean hourly rainfall of 40 mm Humidity level upto 95%, (HR/ Vikram/Any MNRE Approved)VIII. Strip must contain the following detailsa) Name of Manufacturerb) Model or type numberc) Serial No.d) Year of makeIncluding cost of Panel mounting structure)
2
Supplying and fixing 18W Luminaries comparise of:a)18 W, LED (Philips/Osram/equivalent reputed make with BISCertificatete)b) Charge controller and it should have over charge protection,deep discharge protection, Batterys reversed polerty protection,Load short circuit protection, Open circut protection, panelrevers polarity protection. Over temperature protectionc) Automatic dusk to dawn controlling system to monitor theLED operation.
3
Supply and commissioning of LiPo4 Battery. LITHIUM FERRO Batteries 12.8V, 30AH. (The batteries having BIS Certificat).The battary should have battery managementsystem (BMS) with higher life expectancy,longer cycle life,low discharge rate and charge faster facilities.(MAKE-OKAYA/ Warree/ARTECH ENERGY/AMTEK) Battary must have 5 years warranty period.
4
Supply and installation of G.I pole 6 m long, 100mm outer dia 3.6mm thick conforming to IS 1161: 2014 with corrosion proof galvanisation conforming IS 2629-1965 with pole cap at top and base plate 200mmx200mmx10mm with CC foundation having 600mmX600mmX150mm thick CC (4:2:1) Base block below base plate with metal including CC with metal chips (6:3:1) of size 600mmx600mmX1000mm below the ground level surrounding the pole and muffing 300mm dia. and 300 mm hight above ground level including 3mm thick neat cement finishing an dGI earth bolt after making drilled holes etc on pole & carrage of pole at work- site including including filling up the ecavatted earth pit with shifted soil and remaining properly
5
Cable & LugsProviding Cables(including cables from pole top to Panels on Roof top) and other electrical fixtures.2.5 sq mm copper standard pvc insulated and unsheathed wire will be used.(MAKE- MESCAB/POLYCAB/KEI) & Lugs as per requirement
6
Installation of solar panel including connection of lighting fixture, batteries and panel with commissioning and testing of the system
7
Sypplying, fixing & fixing display board or murblae Stone with suitable brick worksas per G.S.
8
Comprehensive maintenance (At least three comprehensive maitenance per year)
9
Sub Total
10
GST 18%
11
CESS 1% Please Enable Macros to View BoQ information