| 1 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.1 Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 2 | In all type Soil AC/PVC/HDPE pipe |
| 3 | 50/63/75mm |
| 4 | 80/90mm |
| 5 | 100/110mm |
| 6 | 125/140mm |
| 7 | 150/160/180mm |
| 8 | 200/225mm |
| 9 | 250/280mm |
| 10 | 300/315mm |
| 11 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.2 Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 12 | In all type Soil |
| 13 | 100mm |
| 14 | 125mm |
| 15 | 150mm |
| 16 | 200mm |
| 17 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.3 Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) |
| 18 | In all type Soil |
| 19 | 50/63/75mm |
| 20 | 80/90mm |
| 21 | 100/110mm |
| 22 | 125/140mm |
| 23 | 150/160/180mm |
| 24 | 200/225mm |
| 25 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.4 Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost) |
| 26 | In all type Soil |
| 27 | 80 mm |
| 28 | 100 mm |
| 29 | 125 mm |
| 30 | 150 mm |
| 31 | 200 mm |
| 32 | 250 mm |
| 33 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.5 Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. |
| 34 | In all type Soil |
| 35 | 75 mm |
| 36 | 90/80 mm |
| 37 | 110/100 mm |
| 38 | 140/125 mm |
| 39 | 180/160/150 mm |
| 40 | 225/200 mm |
| 41 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.6 Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. |
| 42 | In all type Soil |
| 43 | 80 mm |
| 44 | 100 mm |
| 45 | 125 mm |
| 46 | 150 mm |
| 47 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.7 Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour. |
| 48 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.9 Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost). |
| 49 | In all type Soil |
| 50 | 80 mm to 110 mm |
| 51 | 125 mm to 165 mm |
| 52 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.10 Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost). |
| 53 | In all type Soil |
| 54 | 80 mm to 100 mm |
| 55 | 125 mm to 150 mm |
| 56 | 200 mm to 300 mm |
| 57 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.12 Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size |
| 58 | In all type Soil |
| 59 | 50 to 75 mm |
| 60 | 80-110 mm |
| 61 | 125 to 165 mm |
| 62 | 200 to 300 mm |
| 63 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.13 Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution CI/DI/MS pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size |
| 64 | In all type Soil |
| 65 | 80-100 mm |
| 66 | 125 to 150 mm |
| 67 | 200 to 300 mm |
| 68 | 350 to 450 mm |
| 69 | PHED BSR (O&M) 2020: D&S/BSR/2020-21/365-374 Dt. 20.05.2020 1.15 Restoration of cement concrete road including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compacting cement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction of engineer incharge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job. |
| 70 | RUDIP-2022 / A - MACHINARY/00010001 - Hydraulic Excavator of 1 cum bucketNote-1: Hire charges include cost of services of operating staff, Cost of lubricating oil, diesel / Petrol/ Kerosene oil, other consumables for running the plant and machinery and excluding GST.Note-2: The hire charges of plant & machinery on per day basis are for single shift of eight working hours. |
| 71 | RUDIP-2022 / A - MACHINARY/00470047 - Crane 5 tonne capacityNote-1: Hire charges include cost of services of operating staff, Cost of lubricating oil, diesel / Petrol/ Kerosene oil, other consumables for running the plant and machinery and excluding GST.Note-2: The hire charges of plant & machinery on per day basis are for single shift of eight working hours. |
| 72 | FABRICATION WORKS |
| 73 | 5.1 - Turning of various sizes of CID Joints Class- 10/ 15 Complete set (Labour Charges), The Joints will be supplied by the Junior Engineer concern of Department and carting to workshop and after turning of these joints, firm is liable to transport upto Junior Engineer concern's store own his cost. |
| 74 | 5.1.3 - 125 mm dia |
| 75 | 5.1.4 - 150 mm dia |
| 76 | 5.1.5 - 200 mm dia |
| 77 | 5.1.6 - 250 mm dia |
| 78 | 5.1.7 - 300 mm dia |
| 79 | 5.4 - Welding on M.S. / G.I./CI Pipes and other material by Electric Welding, this includes all the material like welding rods/ equipment like welding machine/ generater, if required for job. |
| 80 | 5.4.1 - At Workshop |
| 81 | 5.4.2 - On Site |
| 82 | 5.5 - Providing, Fabrication of Mild Steel Plane Ended/ Flanged Specials like Tees, Bends, Reducers, Enlargers, Plugs, Tail Pieces and Blank Flange made from MS pipes, MS sheet strip and MS Sheet of required sizes by welding, cutting and treading as per site conditions and as directed by the Engineer- In- Charge complete in all respect. |
| 83 | 5.7 - Making of GI Assembly pipe for various sizes including threading, tightening, welding of flange and welding with MS Patti, holes and cable grove making as per required length of 3.00 M/ 6.00 M (Pipse and flangse shall be provided and carting these to workshop by the the department). Length of MS strip will be 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flange. Holes in the flanged will be standard size and above 12 mm dia. in size. After tightening the pipe and flanged, welding will be done at junction of flange and pipe complete in all respect. After preparing of Assembly Pipes, the firm is liable to transport these to concern's divisional store own his cost. |
| 84 | 5.7.1 - 50 mm |
| 85 | 5.7.2 - 65 mm |
| 86 | 5.11 - Supplying of MS Rods and Chuck Nut (Complete Set) for different sizes of sluice valve and should be supplied as according to size of Check Nut including material for the following sizes. |
| 87 | 5.11.1 - Sluice Valve Size 80mm |
| 88 | 5.11.2 - Sluice Valve Size 100mm |
| 89 | 5.11.3 - Sluice Valve Size 125mm |
| 90 | 5.11.4 - Sluice Valve Size 150mm |
| 91 | 5.11.5 - Sluice Valve Size 200mm |
| 92 | 5.11.6 - Sluice Valve Size 250mm |
| 93 | 5.11.7 - Sluice Valve Size 300mm |
| 94 | 5.12 - Making Direct Pump Piece with heavy duty pipes (Class- B) and flange (as per table- D) including cutting of pipe, threading welding and MS strip for length - 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flanged will be standard size and above 15 mm in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material. The Length of Direct Pump Piece will be 30 cm (300 mm). |
| 95 | 5.12.1 - 2\\" dia. Size (50 mm) |
| 96 | 5.12.2 - 2 ½\\" size (65 mm) |
| 97 | 5.13 - Making Reducer Pump Piece with heavy duty pipes (Class- B) and flange (as per table- D) including cutting of pipe, threading welding and MS strip for length - 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flange will be standard size and above 15 mm dia. in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material (Both the larger and smaller pipe will have equal length making reducer). The Total Length of Reducer Pump Piece will be 30 cm (300 mm). |
| 98 | 5.13.1 - 2x2 ½ “ dia size (50 x 65 mm) |
| 99 | 5.13.2 - 2 ½ “x 3” dia size (65 x 80 mm) Please Enable Macros to View BoQ information |