| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil0.00 LVL. TO 1.50 MTR. |
| 2 | 1.50 LVL. TO 3.00 MTR. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 7 | Construction of drain along with apron. 150X150MM |
| 8 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at Ground Floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). LintelGround Floor (Plinth band)Ground Floor (Lintel) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Slab |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Column |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Foundation Footing |
| 13 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :400 mm dia piles |
| 14 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 15 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 16 | Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work. |
| 17 | Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand).Ground Floor |
| 18 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)Ground Floor |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 20 | (b) Double leaf |
| 21 | Providing and fixing factory made UPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per lS 1367:Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners,including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 22 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Frame size 50 x 100 mm |
| 23 | TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. Ground Floor |
| 24 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 25 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.Ground Floor |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.Ground Floor |
| 27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING)Ground Floor |
| 28 | Providing and fixing lst quality ceramic glazed wall tiles conforming to lS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ('1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3k9 per sqm, Including pointing in white cement mixed with pigment of matching shade complete.Ground Floor |
| 29 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. [Flooring]Ground Floor |
| 30 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4 mm thick |
| 31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 32 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 35 | Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 36 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 37 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete(a) 250 mm x 10mm |
| 38 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 39 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 40 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 41 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete. |
| 42 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 43 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 44 | Suspended floors, roofs, landings, balconies and access platform. |
| 45 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100) specifications. (Suspension system to have sillhoute profiles) - (Knauf ceiling solutions) |
| 46 | INTERNAL ELECTRICAL WORKSSUBHEAD- I: INTERNAL POINT WIRINGWiring for light point/ fan point/ exhust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conduct single core cable in surface / recessed medium class PVC conduit, with modular switch,module plate,suitable G.I box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper condutor single core cable etc. as requireGroup C |
| 47 | Wiring for group controlled (looped) light point / fan point / exhaust fan point/ call bell point (without independent switch etc.) with 2Rx1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. Group C |
| 48 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular plate, suitable G.I box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC iMRulated copper conductor, single core cable in surface/ recessed in Heavy duty Rigd PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 50 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 51 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 52 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 53 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 54 | Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 55 | Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 56 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 57 | 25 mm |
| 58 | 32 mm |
| 59 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 60 | 15/16 A switch |
| 61 | 3 pin 5/6 A socket outlet |
| 62 | 6 pin 15/16 A socket outlet |
| 63 | Extra GI box along with modular base and cover plateSupplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required.1 or 2 Module (75mm x 75mm) |
| 64 | 3 Module (100mmX75mm) |
| 65 | 4 Module (125mmX75mm) |
| 66 | 6 Module (200mmX75mm) |
| 67 | 8 Module (125mmX125mm) |
| 68 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 69 | Supplying and fixing 25mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 70 | S&F of following way, single pole and netural, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar , earth bus, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator)6 way, Double door |
| 71 | S&F of following way, horizontal type three pole and netural, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar , earth bus, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator)8 way (4 +24) Double door |
| 72 | S&F of following way surface/ recess mounting, vertical type,415 V , TPN MCB distribution board of sheet stell,dust protection, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer) as required. ( Note: Vertical type MCB TPDB is normally used where 3 ohase outlets are required.)4 way (4 +12) Double door |
| 73 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of followings poles in the exisiting MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 74 | Double Pole |
| 75 | Triple Pole |
| 76 | Supplying and fixing following rating,four pole, 415 V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 77 | 100 A |
| 78 | Supplying and fixing following rating, double pole, ( single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connection, testing and commissoning etc. as required.25 A |
| 79 | Design, manufacture, supplying, fixing in position, testing and commissioning of following LT switchgear panels made up of 14/16G CRCA sheet, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification.KITCHEN SDB |
| 80 | Supply, laying and testing of under noted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.3Cx 2.5 sq.mm |
| 81 | 3.5Cx 25 sq.mm |
| 82 | Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.3.5 X 25 sq. mm (28mm) |
| 83 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 84 | Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. charcoal/coke and salt as required. |
| 85 | Providing and fixing 25 mm X 5 mm G,I. strip on surface or in recess for connections etc. as required. |
| 86 | Providing and laying earth connection from earth electrode with 6 SWG G.I. wire in 15mm dia. G.I. pipe for earth electrode including connection with G.I thimble excavation and re-filling. as required. |
| 87 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm wide X 50 mm depth X 1.6 mm thickness |
| 88 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm wide X 50 mm depth X 1.6 mm thickness |
| 89 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%,, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm wide X 50 mm depth X 1.6 mm thickness |
| 90 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross member with perforation not more than 17.5%,, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150mm wide X 50 mm depth X 1.6 mm thickness |
| 91 | Supply, Installation, Testing & Commissioning of surface indoor downlight connecting fitting made of die cast aluminium &PMMA diffuser having Dia 200mm & H-48mm. Fixture have minimum efficacy -100lumens/watt and system lumen output of 1800lumens and system wattage of 18W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 3000K/4000K/6000K, , IP rating - IP20, CRI >80 SDCM < 5, PF >0.95, THD<10% and an operating Voltage Range of 100-300 Internal Surge Protection 3.5KV.The fixture comply with the EMC/EMI. |
| 92 | Supply, Installation, Testing & Commissioning of LED TUBE LIGHT connecting fitting made of extruded aluminium &PMMA diffuser having width -50mm & L-1200mm. Fixture have minimum efficacy at System level (Not Chip Level) -100lumens/watt and system lumen output of 2200 lumens and system wattage of 22W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 3000K/4000K/6000K, IP rating - IP20, CRI >80 SDCM < 5, PF >0.95, THD<10% and an operating Voltage Range of 100-300 Internal Surge Protection 4KV.The fixture comply with the EMC/EMI . |
| 93 | Supply, Installation, Testing & Commissioning of Bulk head light connecting fitting made of die cast aluminium having dim- L-189mm,W-109mm & H-67mm. Fixture have minimum efficacy -100lumens/watt and system lumen output of 1200lumens and system wattage of 12W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 6000K, , IP rating - IP65, CRI >80, SDCM < 5, PF >0.95, THD<15% and an operating Voltage Range of 100-300 Vac, Internal Surge Protection 2.8KV.The fixture comply with the EMC/EMI. |
| 94 | SICT wall mounting fan suitable to operate at single phase 230v AC supply.400mm Sweep |
| 95 | SICT ceiling fan suitable to operate at single phase 230v AC supply.1200mm Sweep |
| 96 | Supplying, erection, connecting, testing and commissioning of following size exhaustfan complete with gravity louver and connection with 3 core flexible wire as required with all required accessories300mm 900 RPM |
| 97 | Supply and fixingof Mirror Wall Light oblong10 Watt LED luminaire with driver set confirming to IP 65 and above Protection . complete in all respects |
| 98 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 99 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with rough backing.30 mm thick |
| 100 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 101 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 102 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand.Ground Floor |
| 103 | Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng verticalLy or horizonta ly as required |
| 104 | Add for Sikhar & ornamental works |
| 105 | 32 mm |
| 106 | Supplying and fixing following size/modules, GI box along with modular base and cover plate for modular switches in recess etc. as required.1 or 2 Module (75mm x 75mm) |
| 107 | 100 A |
| 108 | Supplying and fixing following rating, double pole, ( single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connection, testing and commissoning etc. as required.40 A |
| 109 | Supply, laying and testing of under noted sizes of copper conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.4Cx 16 sq.mm |
| 110 | Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.4Cx 16 sq.mm(28 mm) |
| 111 | Supply, Installation, Testing & Commissioning of surface indoor downlight connecting fitting made of die cast aluminium &PMMA diffuser having Dia 200mm & H-48mm. Fixture have minimum efficacy -100lumens/watt and system lumen output of 1800lumens and system wattage of 18W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 3000K/4000K/6000K, , IP rating - IP20, CRI >80 SDCM < 5, PF >0.95, THD<10% and an operating Voltage Range of 100-300 Internal Surge Protection 3.5KV.The fixture comply with the EMC/EMI. |
| 112 | Supply, Installation, Testing & Commissioning of LED TUBE LIGHT connecting fitting made of extruded aluminium &PMMA diffuser having width -50mm & L-1200mm. Fixture have minimum efficacy at System level (Not Chip Level) -100lumens/watt and system lumen output of 2200 lumens and system wattage of 22W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 3000K/4000K/6000K, IP rating - IP20, CRI >80 SDCM < 5, PF >0.95, THD<10% and an operating Voltage Range of 100-300 Internal Surge Protection 4KV.The fixture comply with the EMC/EMI . |
| 113 | Supply, Installation, Testing & Commissioning of Bulk head light connecting fitting made of die cast aluminium having dim- L-189mm,W-109mm & H-67mm. Fixture have minimum efficacy -100lumens/watt and system lumen output of 1200lumens and system wattage of 12W . Luminaire have Life of 50000hrs@L70B50 Lumen maintenance, CCT 6000K, , IP rating - IP65, CRI >80, SDCM < 5, PF >0.95, THD<15% and an operating Voltage Range of 100-300 Vac, Internal Surge Protection 2.8KV.The fixture comply with the EMC/EMI. |
| 114 | Supply and fixingof Mirror Wall Light oblong10 Watt LED luminaire with driver set confirming to IP 65 and above Protection . complete in all respects |
| 115 | Supply and fixing of 10Watts Decorative wall washer LED luminaire with driver set confirming to IP 65 and above Protection . complete in all respects |
| 116 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 117 | Supplying wall mounting fan suitable to operate at single phase 230v AC supply.400mm Sweep |
| 118 | Supplying, erection, connecting, testing and commissioning of following size exhaustfan complete with gravity louver and connection with 3 core flexible wire as required.300mm 900 RPM |
| 119 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect including connecting copper wiring.CAT-AAA |
| 120 | Supply and fixing of IP 68, Inground Walkover light fixture with 50W LED , Floor embedded, Colour temperature: 3000K/4000K/5000K, spiral earthing using GI wire complete with all neccessory accessories. |
| 121 | Supplying & fixing - flexible LED Strip Light 25W Power consumption in 5 mtrs length CCT 6500 degrees K, CRI>70% efficacy > 80 Lumend per watt, life >25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF >0.95, power loss should <5% of lamp wattage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved with 2 years warranty against any manufacturing defect working under standard electrical condition. |
| 122 | Add for Sikhar & ornamental works |
| 123 | 32 mm |
| 124 | 100 A |
| 125 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 126 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Initial Test |
| 127 | Routine Test |
| 128 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 129 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 130 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 ('1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement:2 stone dust) admixed with pigment to match the shade of slone and pointing with same mortar.Red sand stone |
| 131 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 132 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 133 | Pond Lining with Geotextile membrane 200 gsm /HDPE |
| 134 | TENSILE STRUCTURE SITTING AREAEarth work in excavation by mechanical means' (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the |
| 135 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 136 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 137 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 138 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
| 139 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level |
| 140 | 1:3:6 (1 Cement 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm (nominal size) |
| 141 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 142 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : |
| 143 | Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) |
| 144 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). |
| 145 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.150 KG / CUM |
| 146 | Painting roofs or orther iron work in large area with one cost of ready mixed paint priming one coat of approved paint (British ANTISOL) including supply of all materials, labour & T & P etc. required for proper completion of the work. Paint to be used should confirm 1.3.1. No. 103-1950. Coat for area of 650 sft. Priming coat. |
| 147 | As in item no-644 above but every coat after the first coat |
| 148 | Design built, supply and erection of Tensile (fabric) structure system including designing and fabrication in M.S. steel tubular structure as per Indian standard section as per approved design and shape including base plate, dash fastener, clits etc. Cutting, patterning, plotting and wielding of fabric with the help of tensile structure software. Fabric should be wielded by high frequency PVC wielding in proper line with PVC cader to be fixed on end of the fabric and to be stretched & fixed on M.S. design structure with the help of. M.S. Flat bar with self-taping screw. M.S. structure to be painted with one coat of epoxy primer with MRF PU paint of approved colour in desired shape. With 1050 GSM tensile fabricWith precontraint tensile membrane 1050 GSM (20 years Warranty)Tensile (fabric) structure system |
| 149 | OPEN AIR THEATREEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil0.00 LVL. TO 1.500 LVL. |
| 150 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25Ground Floor |
| 151 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 152 | PARGOLAEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil0.00 LVL. TO 1.500 LVL. |
| 153 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 154 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 155 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. works). |
| 156 | PLANTER TYPE-IEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil0.00 LVL. TO 1.500 LVL. |
| 157 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 158 | PLANTER TYPE-IIEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil0.00 LVL. TO 1.500 LVL. |
| 159 | INTERLOCKINGEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil (DSR-2.6.1) |
| 160 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres (DSR-16.1) |
| 161 | Supplying and stacking at site: 90 mm to 45 mm size stone aggregate. (DSR-16.3.1) |
| 162 | 63 mm to 45 mm size stone aggregate (DSR-16.3.2) |
| 163 | Local Sand @ 25% of Item No. 3a (DSR-2.27) |
| 164 | Stone screening 11.2 mm nominal size (Type B) (DSR-16.3.7) |
| 165 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . (DSR-16.4) |
| 166 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarsesand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. [DSR-16.68] |
| 167 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick.D.S.R.-11.26.1TAKEN 30% ONLY |
| 168 | C.C. ROADEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil (DSR-2.6.1) |
| 169 | 63 mm to 45 mm size stone aggregate (DSR-16.3.2) |
| 170 | Local Sand @ 25% of Item No. 3a (DSR-2.27) |
| 171 | Providing & laying of a separation membrane between the concrete slab & the sub-base of impermeable plastic sheet 125 microns thick laid flat without creases. Overlap of plastic sheet is necessary and should be 300mm. The separation membrane is to be stuck to the lower lvl. with patches of adhesives or concrete nails with washer. (M.R.) |
| 172 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete prepared with batch mixing machine .D.S.R.-16.43.1 |
| 173 | • After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.• The construction joints shall be provided by groove cutting of size 4 mm x 20 mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.)D.S.R.-26.83 |
| 174 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. (DSR- 16.46.1)Using grade 'A' sealing compound. |
| 175 | RED SAND STONE PATHWAYEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil (DSR-2.6.1) |
| 176 | 63 mm to 45 mm size stone aggregate (DSR-16.3.2) |
| 177 | Local Sand @ 25% of Item No. 3a (DSR-2.27) |
| 178 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 179 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-200. |
| 180 | As in item 3 above but in R.C.C. columns in1:1.5:3having strength not less than M-20. |
| 181 | As in item 3 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 182 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 183 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 184 | HORTICULTURE BOQUprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. |
| 185 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 186 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) |
| 187 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 188 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 189 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). |
| 190 | Rough dressing the trenched ground including breaking clods. |
| 191 | Fine dressing of the ground as level specified. |
| 192 | Supplying & Stacking of Selection No.1 Grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge |
| 193 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 1.2m dia and 1.2 m deep tree |
| 194 | Planting best quality container- grown healthy trees of species and height as specified. All trees to be approved before planting. Inclusive of maintenance (as specified in section I, item 6.2) for one year after planting.Anthocephalus Cadamba |
| 195 | Jacaranda Minsofolia-Height-3.0 Mtr. |
| 196 | Cassia fistula-Height-3.0 Mtr. |
| 197 | Bahunia Purperia-Height-3.0 Mtr. |
| 198 | Azadirachta Indica-Height-3.0 Mtr. |
| 199 | Plumeria alba-Height-3.0 Mtr. |
| 200 | Erythina Indica-Height-3.0 Mtr. |
| 201 | Thespesia Papulana-Height-3.0 Mtr. |
| 202 | Butea monosperma-Height-3.0 Mtr. |
| 203 | Sheesam-Height-3.0 Mtr. |
| 204 | Pongomia pinata-Height-3/0 Mtr. |
| 205 | Ficus Black-Height-3.0 Mtr. |
| 206 | Parijaat Tree-Height-3.0 Mtr. |
| 207 | Termenalia Mantaly-Height-3.0 Mtr. |
| 208 | Plumeria Rubra-Height-3.0 Mtr. |
| 209 | Mangolia Grandiflora-Height-3.0 Mtr. |
| 210 | Ficus Benjamina-Height-3.0 Mtr. |
| 211 | Chorosia speciosa-Height-3.0 Mtr. |
| 212 | Kalpvrisksha-Height-3.0 Mtr. |
| 213 | Syzygium cumini-Height-3.0 Mtr. |
| 214 | Lagestomia speciosa-Height-3.0 Mtr. |
| 215 | Mimosoups elengi-Height-3.0 Mtr. |
| 216 | Delonix Resia-Height-3.0 Mtr. |
| 217 | Bahunia alba-Height-3.0 Mtr. |
| 218 | Conocarpus-Height-3.0 Mtr. |
| 219 | Ficus benghalensis-Height-3.0 Mtr. |
| 220 | Grevelia robusta-Height-0.3 Mtr. |
| 221 | Mohagany-Height-3.0 Mtr. |
| 222 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 223 | Planting best quality bushy shrubs with healthy root ball, of species and height as specified. All shrubs to Planting best quality pot-grown healthy shrubs of species and height as specified, inclusive of preparation and cultivation of shrub beds as specified in section I. All plants to be approved before planting. Inclusive of maintenance (as specified in section I, item 6.2) for one year after planting.Ficus Panda Ball -Height-0.6 Mtr. |
| 224 | Ficus Panda-Height-0.6 Mtr. |
| 225 | Bougainvilea -Height-0.6 Mtr. |
| 226 | Hymenocallia Littoralis-Height-0.6 Mtr. |
| 227 | Cycus Circinalis -Height-0.6 Mtr. |
| 228 | Maurya Exotica -Height-0.6 Mtr. |
| 229 | Junipperus sinensis -Height-0.6 Mtr. |
| 230 | Cycus revoluta -Height-0.6 Mtr. |
| 231 | Nirium olenders -Height-0.6 Mtr. |
| 232 | Hamelia Petens -Height-0.6 Mtr. |
| 233 | Leucophylum -Height-0.6 Mtr. |
| 234 | Pennisettum red -Height-0.6 Mtr. |
| 235 | Furkaria -Height-0.6 Mtr. |
| 236 | Bismarkia -Height-0.6 Mtr. |
| 237 | Clerodendrum Inerme-Height-0.6 Mtr. |
| 238 | Jasminum-Height-0.6 Mtr. |
| 239 | Phasphyllum |
| 240 | Ixora Cocsiconia |
| 241 | Wadelia trilobata-Height-0.2 Mtr. |
| 242 | Lantana Salwania-Height -0.2 Mtr. |
| 243 | Lantana camara-Height -0.2 Mtr. |
| 244 | Aspergous-Height-0.2 Mtr. |
| 245 | Clorophylum green-Height-0.2 Mtr. |
| 246 | Verigated Dinnella-Height-0.2 Mtr. |
| 247 | Eranthenum green-Height-0.2 Mtr. |
| 248 | Eranthenum Red-Height-0.2 Mtr. |
| 249 | Duranta golden-Height-0.2 Mtr. |
| 250 | clerodendrum splendens |
| 251 | Jasminum Grandiflora |
| 252 | Marigold |
| 253 | Dahlia |
| 254 | Chrysanthemum |
| 255 | Petunia |
| 256 | Salvia red HYBRID |
| 257 | Mango -3m+ |
| 258 | Bael - 3m+ |
| 259 | Guava -3m+ |
| 260 | Taramrind -3m+ |
| 261 | Phalsa -3m+ |
| 262 | Citrus Fruit - KagziNimbu,Chakotra,Kinoo,Masumai,Amla-3m+ |
| 263 | GAZEBO-IEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil0.00 MT TO 1.50 MT |
| 264 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)Ground Floor |
| 265 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface)Ground Floor |
| 266 | GAZEBO-IIEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil0.00 MT TO 1.50 MT |
| 267 | As in item 6 but for the lighter beams i.e. having spans upto 6 m.Ground Floor |
| 268 | As in item 6 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 269 | WALL ART MURALSInscriptions honoring Baba Guru Gorakhnath, blend spiritual reverence, historical context, and yogic philosophy. Story,Timeline,Spiritual contributions related art work.Symbolic & Philosophical Lines. |
| 270 | Spiritual Teachings & QuotesTimelinepanels showing key events in Gorakhnath’s life Map panels of Nath pilgrimage circuitsTimeline/Journey on memorial columns STONE PITCHING INCLUDED |
| 271 | Drop off water feature with Electromechanical work |
| 272 | WELCOME TO BABA GORAKHNATH TEXT ON WALL INCLUDED IN STEELBENCHES |
| 273 | DUST BINS |
| 274 | Entrance Signage 20 ft x 4 ft on Rock stone Instrucion Signage 4 ft x 6 ft on Steel Finish2”x2” square pipe with Lighting and Complete in all respect. |
| 275 | Pylon for the park in wood finish Mapping On frame with 3d view |
| 276 | GI Box letter on 1.25 mm Gi sheet with ADS LED Module 1.5 watt with 5 years warranty & water proof Power Supply 3 years warranty |
| 277 | Directional & Instruction Signage |
| 278 | INTERPRETATIVE PANELS -JOURNEY BABA GORAKHNATH LIFE ,PHILOSPHY & TEACHINGS55''INCH VIDEO WALL MONITOR 3.5 MM (PM550NX) |
| 279 | HDMI 1/16 DISTRIBUTER |
| 280 | WALL PUSH OUT BRACKET (BR-001) |
| 281 | DSS 55INCH A11 2GB 16GB FLOOR MOUNT NON TOUCH |
| 282 | HDMI 1/12 DISTRIBUTER |
| 283 | HDMI 1/4 DISTRIBUTER |
| 284 | INTERACTIVE EXHIBITS |
| 285 | MURAL,INCRIPTIONS AND NATH ICONOGRAHY |
| 286 | Onsite Installation Service |
| 287 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 288 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)Ground Floor |
| 289 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 290 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 291 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 292 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)(a) 35 mm thick |
| 293 | Three track three panels sliding window with two glazed & one wire mesh panels with alluminium channel for roller track, wool pile, nylon rollers with s.s. 304 body.including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Using R2 series with foame (70mm & above)x(40 mm & above) & both glazed and fly screen sash (25 mm & above)x(50mm & above with zinc alloy (zamak) powder coated touch lock with hook (Height up to 1.20 meter) |
| 294 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqmGround Floor |
| 295 | jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 296 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 297 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 298 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 299 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required |
| 300 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 301 | INTERIOR WORKSWALL PANELLING (MEETING ROOM/INTERPRETATION CENTRE/LIBRARY/GUEST ROOM) |
| 302 | DOUBLE BED |
| 303 | RECEPTION TABLE |
| 304 | OFFICE TABLE |
| 305 | EXECUTIVE CHAIR |
| 306 | VISITORS CHAIR |
| 307 | MEETING ROOM |
| 308 | LIBRARY SHELF |
| 309 | FRIDGE |
| 310 | KITCHEN EQUIPMENTS (FRYERS/GRILLERS/OVEN/REFRIGERATION UNITS/DISHWASHING STATION/STATINLESS STEEL WORK TABLE/TANDOOR/BURNER/CHIMNEY/UTENSIL/ ETC) |
| 311 | LANDSCAPE AUTOMATIC IRRIGATION SYSTEM Pipes Work: Supply, Installation, Testing and commissioning of PVC pipe conforming to IS:4985:2000 and suitable for the respective working pressures without all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instructionPVC pipe 75mm-10 kg/cm² |
| 312 | PVC pipe 63mm-6 kg/cm² |
| 313 | PVC pipe 50mm-6 kg/cm² |
| 314 | PVC pipe 40mm-6 kg/cm² |
| 315 | Earth work excavation and refilling 300x450mm |
| 316 | Supply, Installation, Testing and commissioning of flexible,kink resistant 16mm Blank tubing and resistance to UV damage and algae growth brown in colour and wall thickness 1.2mm, pressure rating 1.0 to 3.5Bar with all brown colour fittings. |
| 317 | Supply, Installation, Testing and commissioning of Point source emitter pressure compensating with self flushing emitter, and selfpiercing barbs,flow rates 1.89 lph to7.57 lph UV resistant colour coded with working pressure 1.4 to 3.5bar XB |
| 318 | Supply, Installation, Testing and commissioning of flexible,kink resistant 16mm inline tubing with pressure compensating, self flushing mechanism , Flat emitter and resistance to UV damage, algae growth brown in colour, Longer lateral run lengh with flow rate 2.4lph / 3.8 lph @ 30cm /45cm, pressure rating 1.0 to 3.5 bar wall thickness 1.2mm with all brown colour fittings. |
| 319 | Supply, Installation, Testing and commissioning of 9 - Gauge Galvanized Steel Rod Comes Sharp tips provide easy insertion into all soil types, Staple Distribution Tubing , Drip Line or Tubing to Finished Grade. Notched Sides. Corrosion -Resistant of TIE DOWN STAKE etc. omplete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 320 | Supply, Installation, Testing and commissioning of 40mm/50mm/63mm dia self-closing flushing valves that are installed at the end of the irrigation line for effecting flushing of the line at the beginning of every irrigation cycle, thus avoiding the clogging of the emitters /sprinklers through removal of particles, sediments and other impurities from the water. etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 321 | Supply, Installation, Testing and commissioning of 1\\" Large Capacity Y Type Disc / Screen Filters for submain filtration Have High Flow & Low Maintenance With a Solid Build, Maximum Flow Up to 26 gpm (6m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 322 | Supply, Installation, Testing and commissioning of 1.5\\" Large Capacity Y Type Disc / Screen Filters for submain filtration Have High Flow & Low Maintenance With a Solid Build, Maximum Flow Up to 88 gpm (20m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 323 | Supply, Installation, Testing and commissioning of 2\\" Large Capacity Y Type Disc / Screen Filters for sub main filtration Have High Flow & Low Maintenance With a Solid Build, Maximum Flow Up to 110 gpm (25m³/hr), Maximum Pressure 116 psi (8 bar),Maximum Temperature Up to 140ºF (60ºC) etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 324 | Supply, Installation, Testing and commissioning of Pro Spray-04 with check valve Series Spray bodies, having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide unmatched resistant to grit with Rotary Pop up having colour coded MP Rotator nozzle with multiple stream water spray capable of covering 2.5m- 10.7m with Matched Precipitation Rate - Circular Pattern / Rectangular Strip Pattern. The nozzle should have popup feature to prevent dirt and debris entering into the spray path. The sprinkler shall be of the viscous fluid brake rotary type and be a multi-stream, multi-trajectory rotating stream sprinkler. The sprinkler shall produce and maintain a matched precipitation rate no greater than 12mm per hour throughout the arc adjustment range and radius adjustment range, (up to 25% of radius reduction), when spaced at 50% of wetted diameter. The part circle sprinkler shall have an infinitely adjustable arc from 45° to 105°, 90° to 210° or between 210° to 270° depending on the model selected. The full circle sprinkler shall irrigate a full 360°. The 45° to 105° model shall not require coverage from adjacent sprinklers closer than 3’ from the head. Full or part circle sprinklers shall be capable of up to 25% radius reduction using a stainless steel radius adjustment screw. The radius reduction screw shall have a slip clutch mechanism to prevent internal damage if turned past the minimum or maximum radius settings. The radius reduction screw shall reduce the pressure and flow upstream of the adjustable orifice thereby maintaining stream integrity. Check valve option eliminates low-head drainage as per the instructions of the Site Engineer / Architect / Landscape Architect |
| 325 | Supply, Installation, Testing and commissioning of 1/2\\" Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 10 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic.SJ512 Series. |
| 326 | Supply, Installation, Testing and commissioning of Imported HDPE service saddle of varying size upto 63mm dia with pressure rating of PN 10 |
| 327 | Supply, Installation, Testing and commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 63mm with pressure rating PN 10 |
| 328 | Supply, Installation, Testing and commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem, Stem O-Ring, non mechanical ,ball Seals with backing seals and a base which permits maximum penetration into the valve of size 50mm. with pressure rating PN 10 |
| 329 | Supply, Installation, Testing and commissioning of PVC Single Union Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem,Stem O-Ring, non mechanical ,ball Seals with backing seals and with a base which permits maximum penetration into the valve of size 40mm. with pressure rating PN 10 |
| 330 | Supply, Installation, Testing and commissioning of a double acting air and vaccum release 2 \\" Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 10 KSC . |
| 331 | Supply, Installation, Testing and commissioning of a double acting air and vacuum release 1/2 \\" Air release valve . The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. Only for Drip Irrigation etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 332 | Supply, Installation, Testing and commissioning of 6\\"Round box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening :6 1/8\\" Dia & Bottom Opening 8 5/8\\" Dia. |
| 333 | Supply, Installation, Testing and commissioning of 10\\" Round Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening 10\\" Dia & Bottom Opening 12 13/16\\" Dia. |
| 334 | Supply, Installation, Testing and commissioning of 12\\" Rectangular Standard Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18 1/4\\" L X 13\\" W & bottom opening :21 1/4\\" L X 15 15/16\\"W X 12\\" H |
| 335 | Supply, Installation, Testing and commissioning of 18'' Jumbo Rectangular Standard Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18 1/4\\" L X 13\\" W & bottom opening :21 1/4\\" L X 15 15/16\\"W X 12\\" H |
| 336 | Supply, Installation, Testing and commissioning of 3/4th Quick coupling valve with Gun metal valve made up of solid brass with locking cover corrosion resistant and stainless steel spring HQ 3RC |
| 337 | Supply, Installation, Testing and commissioning of 3/4th Key threads into top of QCV to provide water access HK-33 |
| 338 | Supply, Installation, Testing and commissioning of 3/4th Hose Swivel Made up of Solid Brass Swivels up to 360 degrees to allows hose to be pulled in any direction & Also to prevent Hose Damage. HS0 |
| 339 | Supply, Installation, Testing and commissioning of 2.5\\" Disc Filter with capacity 40m3/Hr having an suitable inlet connections , to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,3/4\\" outlet for flushing at bottom of filter & maximum working pressure of 10 Bars etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 340 | Supply, Installation, Testing and commissioning of monoblock / openwell submercible pumpset of having discharge and head of design flow, UPVC sch 40 - suction & delivery manifold and mounted on a baseframe with proper supports etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 341 | Supply, Installation, Testing and commissioning of control panel with Siemens Switch Gear Arrangements suitable for pumpset having the Key features , Manual Mode : Push button On / Off Control ,rugged standard 1.6 mm thickness dust & vermin proof enclosure , fuse protectionfor controller to pump enable signal , 8 PIN control relay instead of slim relay , terminal with clamp & sufficient access space , wall mounting clamp provision, digital pump control with external CT , siemens & switch gears, quality proven products with long life assurance., etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 342 | Supply, Installation, Testing and commissioning of Control Cable for Pump Set - 3 core X 4 / 6 Sq.mm Copper cable based on the pump capacity |
| 343 | Supply, Installation, Testing and commissioning of 2.5'' control Valve, Butterfly Valve VAN Stone flange & Tail Piece in mainline for bypass and flow diversion of approved quality with pressure rating of PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 344 | Supply, Installation, Testing and commissioning of 2.5'' Non Return Valve to prevent back flow have flap type or spring type with pressure rating of PN 10 etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 345 | Supply, Installation, Testing and commissioning of Pressure release valve 3\\" with pressure setting from 0 to 7 Bar etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 346 | Supply, Installation, Testing and commissioning of Direct burial 14 Awg x 2 Maxi cable with PVC insulated UL standard 493 with impregnated polyethylene jacket and soft annealed tin coated copper confirming to ASTM B-33 for two way communication between decoder controller and decoders complete. |
| 347 | Supply, Installation, Testing and commissioning of PVC pipe 25mm-10 kg/cm² including fittings and accessories |
| 348 | Supply, Installation, Testing and commissioning of ICC2 54 Station Decoder Controller with two wire path UV resistant,wall mount case,with LCD display and Centralus cloud-based control ,non volatile memory for 100years,10KV surge protectionwith removable front panel and programmable under battery in office,total run time calculator ,short detect errors,one touch watering,wityh contract default programe s,slow closing valve removable battery with sensor terminals ICC2 series |
| 349 | Supply, Installation, Testing and commissioning of EZ DM decoder Module for ICC2 controller. |
| 350 | Supply, Installation, Testing and commissioning of EZ-1 decoder for PRO-C / HPC / ICC2 controller. |
| 351 | Supply, Installation, Testing and commissioning of WIFIKIT / LAN KIT communication module for cloud-based Centralus control - ICC-2 controllers |
| 352 | Supply, Installation, Testing and commissioning of wired Flow Sync Sensor with six blade impeller ,programablefrom computer with accuracy + or - 1%,flow rate 0.5-30feet per sec with 150psi max pressure ,temp upto 60degree centigrade with FCT-200 / 300 with extension wire, etc.,complete , as per the instructions of the Site Engineer / Architect / Landscape Architect |
| 353 | Supply, Installation, Testing and commissioning of Soil Clik sensing device ,to measure soil temp,EC ,Moisture level complete to convert as smart controller,with corrossion resistant sensor and setting thershhold moisture level |
| 354 | Supply, Installation, Testing and commissioning of Solar Sync with rugged plastic construction ,power full micro logger for climatic data collection , to measure air temperature,solar radiation,relative humidity,wind velocity, direction of wind,rainfall as per specifications complete |
| 355 | Supply, Installation, Testing and commissioning of 1\\" Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC construction ,compatible and slow closing to prevent water hammer,pressure rating upto 10 Bar and maximum flow of 9 M3/hr ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance 30ohm with provision to attach Optional Accu Sync |
| 356 | Supply, Installation, Testing and commissioning of 1.5\\" Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC construction ,compatible and slow closing to prevent water hammer,pressure rating upto 10 Bar and maximum flow of 27 M3/hr ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance 30ohm with provision to attach Optional Accu Sync |
| 357 | Supply, Installation, Testing and commissioning of 2\\" Solenoid globe angle inlet Valves with fabric reinforced Nitrile diaphram Material and rugged PVC durable glass -filled nylon construction ,compatible with and slow closing to prevent water hammer,pressure rating upto 10 bar and maximum flow of 34 m3/hr ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance 30ohm with provision to attach Optional Acc Sync |
| 358 | Supply, Installation, Testing and commissioning of 3\\" Solenoid globe Valves with Glass filled nylon and plan material. durable glass -filled nylon construction with fabric reinforced diaphram and rugged PVC construction ,compatible and slow closing to prevent water hammer,pressure rating upto 15 bar and maximum flow of 60m3/hr ,max water temp. upto 42degree centigrade, with 24AC solenoid,current rating 0.41A @60Hz,coil resistance 30ohm with provision to attach ICV Pressure Regulation Optional Accu. Sync |
| 359 | Supply, Installation, Testing and commissioning of Accu Sync to Maintain constant outlet pressure between 1.4 bar to 7.0 bar |
| 360 | Supply, Installation, Testing and commissioning of direct bury -on wire connector with strain relief ,UL486 D certified ,with waterproof silicon sealant ,fits wire from 22ga to6 ga as per specifications complete DBRY |
| 361 | Supply, Installation, Testing and commissioning of Pump relay 24 AC PLA relay ,stabilizer 300watts etc., complete, as per the instructions of Architect/Landscape Architect/Engineer In Charge. |
| 362 | Supply, erection, testing & commissioning of RCC DP structure as per Local electricity board including foundation, painting of structure and materials like GOS, LA's, DOLO fuses, ACSR conductors, insulators, H- frame and other necessary fixing supports and accessories as required. Any items not specified but required to be in comply with the latest Electrical Inspectorate requirement shall be included in the cost of DP structure, but excluding fencing, gate, jelly, earthing etc., |
| 363 | Supply, Installation, Testing & Commissioning of Out-door type, 11KV HT Metering panel with 3CT 3PT for 3phase 4wire metering with transport cover TTB, with 30x8MM Copper busbars (HT metering box fabricated out of 3mm MS sheet duly epoxy powder coated, with out meter). The rate shall include civil foudation with all necessary accessories. ALSO AS PER LOCAL ELECTRICITY BOARD NORMS |
| 364 | 0.2 S Class ETV Meter with ABT Feature & DLMS Protocal with TOD for above. ALSO AS PER LOCAL ELECTRICITY BOARD NORMS |
| 365 | Supply, installation, testing and commissioning of 11kV, 400A, 1no. load break switch. The load break switch shall be erected using necessary accessories all complete as required by Local electricity board / CEIG. The rate shall include cost of necessary civil works as required. |
| 366 | Supplying, erecting, testing and commissioning of 63 KVA, 5Star rated Aluminium wound Distributing Transformer 11KV/433V with off load tap switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, magnetic oil level indicator with +5% to -10% steps of 2.5%, HT and LT cable end boxes including all standard accessories as per latest IS standard technical specifications. The rate shall include cost of necessary civil works as required. |
| 367 | Supplying and fixing of non-skid rubber mat 25mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for H.T. 11 KV panels. |
| 368 | Supplying and fixing of non-skid rubber mat 16mm thick and 900mm width as required including cutting to required lengths of approved make with Test Certificates for L.T. panels. |
| 369 | Supplying and fixing of fire bucket painted red and duly filled with sand conforming toIS: 2546-1974. |
| 370 | Supplying and fixing of MS stand suitable for supporting two buckets (Pedestal type) |
| 371 | Supplying and fixing of shock restoration chart written in English and Hindi duly framed in as required. |
| 372 | Supplying and fixing of carbon dioxide fire extinguisher type 4 kgs. Capacity of approved make with wall mounting bracket as required conforming to IS: 2878/1976 (Push type). |
| 373 | Supplying and fixing of first aid box as approved complete with standard kit as prescribed by Indian Red Cross. |
| 374 | Supply and fixing of H.T. Danger notice plate of 250x200mm made of mild steel at least 2mm thick and vitreous enameled white on both side with inscription in signal red colour on front side as required. |
| 375 | Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.3Cx70 Sq.mm. |
| 376 | Supplying and making Indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.3Cx 70 / 95 Sq.mm. |
| 377 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.3Cx 70 / 95 Sq.mm. |
| 378 | Supplying and laying of the 250mm dia 'B' class GI pipe complete with all accessories as required as per specifications. |
| 379 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia |
| 380 | Supply, erection,fabrication & installation of YARD FENCING for transformer, DG yard. Consisting of 25x50x3mm rectangular pipe panel along with 40x40x6mm equal M.S angle, 100x100x6mm square pipe for supporting poles in the interval of every 1.5.mtr, , lockable hinged gates,the fencing will be erecting on stone masonary wall of size 750mm Ht X 300mm Width X 20mtrs L,on the masonry foundation of fence provided 100mm thick RCC slab with plastering.one coat of Primary & two coats of finished enamel paints for the fence. Height of the fence 2.3mtr on the masonry wall/foundation, etc. along with allrequired Hardware materials like anchor fastners,G.I bolt & nuts with washers,hinges etc. complete. |
| 381 | Supply, laying and Excavation of cable trenches of 300x750MM including filling, cushioning and protective covering complete in all respect Excavation, providing sand for laying cable, covering with bricks, refilling & consolidation etc. |
| 382 | Supply, laying and Constructing water tight brick masonry Inspection Chamber with first class bricks in cement mortar 1:6 (1 cement :6 coarse sand), R.C.C. top slab of 150 mm thick with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) with CI chamber cover for following size of trenches with frame.Foundation concrete 150 mm thick 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:3:6 mix, M.S. foot rests including fixing in 20 x 20 x 10 cm cement conc. blocks neatly finished, complete as per standard design and approved drawings. (Price shall include the cost of excavation, back filling, disposal of surplus earth dewatering and water proofing of manholes as directed at site & other associated civil works).600MMx600MM |
| 383 | Design, manufacture, supplying, fixing in position, testing and commissioning of following LT switchgear panels made up of 14/16G CRCA sheet, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification.MAIN LT KIOSK (OUTDOOR TYPE) |
| 384 | 100A TPN Aluminium Bus Bar With Heat Shrinkable Sleeves of Size 25x5mmx1 Run for Each Phase & Neutral.MAIN EB,DG CHANGE OVER PANEL |
| 385 | INCOMER (I1) :100A TPN 25kA Adjustable Thermal(O/C) & Adjustable Magnetic(S/C) Based MCCB with Extended RHOM, Spreaded Terminals, Aux.Contact.100A 4P, Auto change over switch, Spreaded Terminals, Aux.Contact.R,Y,B LED Indication Lamps.6Amps SP \\"C' Curve MCB for Control Circuit.ON, OFF, TRIP LED Indication Lamps for Breaker.96Sq.mm, Digital Ammeter with Built-in Selector Switch.MAIN LT FEEDER PILLAR (OUTDOOR TYPE) |
| 386 | 100A TPN Aluminium Bus Bar With Heat Shrinkable Sleeves of Size 25x5x1 Run for Each Phase & Neutral.OUTGOING FEEDERSEXTERNAL LIGHTING DB PANEL (OUTDOOR TYPE) |
| 387 | 40A 3Pole AC3 Duty Contactor with Built in Aux. Contact & 220V AC Coil.R,Y,B LED Indication Lamps.6Amps SP \\"C' Curve MCB for Control Circuit.(0-500V) 96Sq.mm, Digital Voltmeter with Built-in Selector Switch.24 Hours Timer - 1 NO 220 VAC.Auto / Manual Selector Switch.OUTGOINGEXTERNAL LIGHTING DB PANEL (OUTDOOR TYPE) |
| 388 | INCOMER (I1) :40A 4P 10KA \\"C' Curve MCB.40A 3Pole AC3 Duty Contactor with Built in Aux. Contact & 220V AC Coil.R,Y,B LED Indication Lamps.6Amps SP \\"C' Curve MCB for Control Circuit.(0-500V) 96Sq.mm, Digital Voltmeter with Built-in Selector Switch.24 Hours Timer - 1 NO 220 VAC.EXTERNAL LIGHTING DB PANEL (OUTDOOR TYPE) |
| 389 | Supply, laying, connecting, termination and testing of under noted sizes of flexible copper conductor flexible PVC sheathed & sleeved and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (in existing trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.3 C x 1.5 sq.mm |
| 390 | 3.5 x 50 sq.mm |
| 391 | 4 x 16 sq.mm |
| 392 | 4 x 10 sq.mm |
| 393 | 4 x 6 sq.mm |
| 394 | Above 35 sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp) |
| 395 | Supplying, Laying, terminating, testing, commissioning of following sizes of Copper Conductor PVC insulated, PVC sheathed armoured cable 1100 V grade. On surface the cable run shall be fixed on G.I. clamps etc of suitable size or as directed by the E-I- C complete in all respects. Supply and providing cable identification markers. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per specifications complete with end termination as required.4 C X 2.5 Sqmm |
| 396 | Supply and making end termination with brass double compression gland including providing and crimping of aluminium solderless lugs / ferrules for XLPE armoured power aluminium conductor cable 1.1 KV grade of following sizes:-3.5 x 50 sq.mm |
| 397 | 4 x 16 sq.mm |
| 398 | 4 x 10 sq.mm |
| 399 | Earthing with G.I earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. charcoal/coke and salt as required. |
| 400 | Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required |
| 401 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 watt to 90 Watt. Confirming to IP 66 protection complete in all respect accessories.CAT- AAA |
| 402 | Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect including foundation and connecting copper wiring with all complete accessories. |
| 403 | Supply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and with inbuilt junction box with MCB,and wiring till fixture, sleeve in foundation,Required T&P completee inall respect accessories |
| 404 | Supply & fixing of 6mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and with inbuilt junction box with MCB,and wiring till fixture, sleeve in foundation,Required T&P completee inall respect accessories |
| 405 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output. Rated life burning hours 50000 hr @ Lumen Maintenance of 70%, CCT>5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire >lk08. Power Factor >0.9 with mains, surge protecction - Min 5KV along with Over volgtage / Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60 Hz application. Compliance to IS 10322/IEC 60598, LM 79 &LM 80 Adherene with RoHS. UL approved MCPCB. LED efficiency > 130 lm/w, nominal CRI >75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & design & development facility crtified by ISO 9001: 2008. Housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia / Luminous / Osram make LED source. a) LED Post top Lantern with 35 watts |
| 406 | Supply and fixing of decorative 12 Watt led SPIKE LIGHT with all complete accessories. |
| 407 | Supply and fixing of decorative 10 Watt led BULKHEAD LIGHT with all complete accessories. |
| 408 | Supply and fixing of decorative 1 Watt led light in pergola with all complete accessories. |
| 409 | Supply and fixing of decorative 20 Watt spot light with all complete accessories. |
| 410 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 411 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 412 | Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications asamended, consisting of Mono/Poly Crystallinesili consolar cells, netmetering facility,necessary protections, earthing, mounted on Aluminium/GIstructure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330W porabove, manufactured in India, conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than16.5%.PV modules used in solar power plants/systems must be warranted for their output peak watt capacity,which should not be less than 90% at the end of 10years and 80% at the end of 25 years. b)Power Conditioning Unit (PCU) of 350-800 VDC Input voltage range and 400V AC, three phase,4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d)Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required. e) Lightning and surge voltage protection. f)Connections & Inter connections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessarychannel/conduitlugs and other accessories etc.as required. |
| 413 | DG SET AND ASSOCIATED WORKSSupplying, installing, testing and commissioning of Diesel Generator set with Mechanical governor for Auto start and stop and following specification. Power rating as per standard reference condition as per BS 5514/ISO 3046/ISO 8528 & IS 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes : Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter. Spin-on dual fuel filter with water separators, Turbocharger, Charge air cooler, silencer (Hospital grade), Dry type air cleaner, shutoff coil, flysheel and flywheel housing. First fill of lube oil and coolant. Safety form low lube oil pressure. Safety for high water temperature, permissible overload of 10 % for one hour in 12 hours of operation. 50KVA |
| 414 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :400 mm dia piles |
| 415 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Initial Test |
| 416 | Routine Test |
| 417 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 418 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). ColumnGround Floor |
| 419 | Excavation carefully by manual means up to 2.00 mtr. Depth without damaging the burried architectural parts of the monument/structure and stacking all the intact parts at proper place for reuse at the time of restoration work as per directionof Engineer-in-charge with in 50mtr lead. |
| 420 | De-vegetation from monument by removing bushes, trees including complete uprooting from the wall & roofs / structures carefully including suitable chemical treatment to roots to avoid further growth including disposal of rubbish within 50 mtr. Lead as per direction of Engineer in-charge. |
| 421 | Filling available excavated earth (excluding rock) in trenches,plinth, sides of foundations etc. |
| 422 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal ofrubbish, lead up to 50 m and lift up to 1.5 m. |
| 423 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of Skm also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides offoundation etc. complete for all lift. |
| 424 | Dismantling reinforced cement concrete or reinforced brick work including stacking of dismantled materials as directed byEngineer-In-Charge within a distance of 60 meters (200 feet). |
| 425 | Careful removal of existing deteriorated /damaged / weathered lime plaster without damaging the below surfaces and including safety precaution, scaffolding and efficient precise tools for removing of plaster as directed by Engineer-in-Charge. |
| 426 | Raking out the joints of country/Nankshahi brick, scooping out dead and decayed mortar very slowly and carefully with scooping rods, then washing complete with hand spray pump. Preparing the surface for replastering including disposal ofrubbish with 50 meter lead. |
| 427 | Raking out joints of brick masonry surface to the required width and depth, with due care and precaution, by mecahnical/manual means, including preparing and cleaning the surface for re-pointing /refiIling of joints, including disposal of rubbishto the ground within 50meter lead. |
| 428 | Taking out bulged/cracked Lakhori brick work at different locations upto a height of 8 meters to 10 meters wall carefu'' including stacking of serviceable material disposal ofUnserviceable material upto a lead of 200 to 500 meters. |
| 429 | Scraping & Removing of white wash/ distemper/oil paint /aIgIi etc. from lime plaster highly decorative, ornamental and stucco work with at most care by using fine sand paper underthe close supervision to keep intact the old designs. |
| 430 | Demolishing brickwork in lime or cement mortar of walls and vaults, arches, slabs etc including stacking of serviceable material and disposal of unserviceable material within 50 meterlead. |
| 431 | Demolishing lime concrete manually/ by mechanical means anddisposal of material within 50 metres lead as per direction of Engineer in-charge. |
| 432 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as perdirection of Engineer - in - charge.Nominal concrete 1:3:6 or leaner mix (i/c equivalent desigPIit |
| 433 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent desigiimix) |
| 434 | Dismantling C.I. or asbestos rain water pipe with fittings andclamps including stacking the material within 50 metres lead :75 to 80mm dia pipe |
| 435 | 100mm dia pipe |
| 436 | Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50metres lead including refilling the excavated gap. |
| 437 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond50 m initial lead, for all leads including all lifts involved. |
| 438 | Stitching / repairing of structural cracks in the brick masonry using local brick & lime mortar matching the traditional lime mortar and bricks as existing in the historic structure after raking, cleaning and washing the cracks, as directed by the Engineer-in charge, including all leads lifts and carriage. Allcomplete. |
| 439 | Stitching / repairing of structural cracks in the brick masonry using local brick & lime mortar matching the traditional lime mortar and bricks as existing in the historic structure after raking, cleaning and washing the cracks, as directed by the Engineer-in charge, including all leads lifts and carriage. Allcomplete. |
| 440 | Providing and fixing chicken wire mesh (6mm x 6mm) of 24 gauge 200 mm wide along the joints of brick work with hooks/nails etc. complete so as to receiving the plastering work over chicken mesh as per the direction of Engineer-in-charge. |
| 441 | Steel-rod stitching in cracked stone patties, beams, and lintels. Providing and fixing stainless steel (316 grade ) rods of 90 cm length of which 15cm on either side and cold bending at 90 degrees. The stainless steel rod to be fixed perpendicular to the crack by drilling in stone and fixing with cement and Araldite mixture in such a way that the entire length of the rod is in complete contact of the stone and the bent ends are fully inserted in the cracked stone. Including making necessary holes for fixing of the steel rod as directed by Engineer-in-charge. |
| 442 | Stitching of cracks in brick masonry with stone lintels of 450x200x50mm. Chasing, grooving the brick masonry and inserting the stone lintel. All around the stone, lime mortarshould be properly packed. |
| 443 | Propping with steel to support the leaned structure ( roof and wall) using pipes, channels, angles, girders , wooden wages to prevent further leaning/ collapse ,mode of measurement(1.the plan area of the propping shall be for payment purpose.2. the payment will be made once only for execution of all item such work. ) |
| 444 | Traditional brick masonry in lakhori bricks in lime mortar in proportion similar to the existing traditional lime mortar 1:1:1 (1 lime: 1 surkhi : 1 fine sand) and including curing, scaffoldingwhere required and 5.0 m lift from plinth level.Lakhori bricks of Size 200mm x 100mm x 40-50mm |
| 445 | Traditional brick work in plain arches in lime mortar 1:1:1 (1lime : 1 coarse sand : 1 surkhi) and including curing, centering, shuttering, scaffolding where required and 5.0m lift from plinth level.Lakhori bricks of Size 200mm x 100mm x 40-50mm |
| 446 | Traditional Brick work in gauged arches in lime mortar 1:1:1 (1 lime : 1 coarse sand : 1 surkhi) and including curing, centering, shuttering, scaffolding, where required and 5.0m lift fromplinth level.Lakhori bricks of Size 200mm x 100mm x 40-50mm |
| 447 | Tuman masonry by brick bats/ stones in grinded mortar of Lime Surkhi mortar 1:2/lime sand mortar 1:2 including racking and removal of all old loose plaster and cleaning the wall surfaceproperly as per direction of Engineer In-charge. |
| 448 | Providing and laying lime concrete in foundation and plinth with 20mm down graded brick bats nominal size and lime mortar comprising of 1 lime putty : 1 surkhi : 1 coarse sand rammed and finished with gur and belgiri treatment includingscaffolding if necessary complete. |
| 449 | Providing and laying lime concrete terracing on roofs with 20mm to 25mm nominal size brick aggregate and 50P« lime mortar 1:2 (1 lime puuty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding offjunctions parapet wall complete |
| 450 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approvedand removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of SUB HEAD : 14-REPAIRS TO BUILDING 1140 Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to bedone. |
| 451 | Providing and fixing 15cm wide, 45cm overall semi-circular plaim G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connectionswith rain water pipes complete.0.80 mm thick with zinc coating not less than 275gm/m^3 |
| 452 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110mm diameter |
| 453 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making goodthe wall etc. complete.110mm diameter |
| 454 | Providing & injecting chemical emulsion for Preconstructional and Postconstructional anti-termite treatment and creating a chemical barrier under & alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall & floor along the external perimeter of building expansion joints surrounding of pipes & coduits etc.complete plinth area of the building at ground floor only shall be measured as per I.S.63/3( part II 1981 ) Aldrine emlsifiable concentrate or any other approved material such as Htrachlore or Chlordance will be used . The rate of application of chemical emulsion shall be as follows:(I) Treatment for masonary & foundation Slitres/ sqm.(II) Back fill in immediate contract with foundation 7.5 litres / sqm(III) Treatment of top surface of plinth filling 5 litres/sqm .(V) Treatment of soil along external perimeter of building 7.50 litres/sqm.(VI) Treatment of soil under Apron along external perimeterSlitres/sqm |
| 455 | Supply and fixing of flush doors, commercial quality conforming of I.S. 2202 part-1 (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts, locks, handles, springs, fitting with necessary screws to be supplied departmentally.35mm thickFor Single leaf Shutters |
| 456 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc.,wherever necessary complete :25 mm dia |
| 457 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including costof adhesive of approved quality.1.0 mm thick |
| 458 | Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain) toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ñ 0.45, U-Value ñ (W/sq.m-K) 5.7W /M2K, Visible lighttransmittance * 0.30) |
| 459 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windowsand clerestory windows with necessary screws :Second class teak wood |
| 460 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions withwire of dia. 0.50 mm all complete.With 2nd class teak wood beading 62X19 mm |
| 461 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete. |
| 462 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dashfastener shall be paid for separately).Second class teak wood |
| 463 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(Note:- Butt hinges and necessary screws shall be paidseparately)35mm thick shutters |
| 464 | Providing and fixing Sawn and planed teak wood for roof beam matching with existing section including removal of old and decayed / damaged roof beam making necessary changes and making good the same etc with all material for span up to 3.6metre. |
| 465 | add extra for span 3.6 m to 5 m |
| 466 | add extra for span 5m to 6m |
| 467 | Providing and fixing bright finished brass handles with screws etc.complete:125mm |
| 468 | 100mm |
| 469 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete :125x64x1.90mm |
| 470 | 100x58x1.90mm |
| 471 | Providing and Fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mmthick hard board backing.Rectangular shape 1500x450 mm |
| 472 | Reinforcing timber beams with steel plates of size 100x300 12mm with bolts and nuts |
| 473 | Reinforcement of existing wooden beams with L shape Angles70x70x6 at the bottom of the beam |
| 474 | 2.5 cm (1\\") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm (3/4\\") graded approved stone laid in panels finished with 3mm. (1/8\\") flooring coat of neat cement or cement and marble dust in 5:1 as specified over & including 8cm (3\\") thick base concrete consisting of cement, local sand and brick ballast 4cm (1.5\\") gauge in the proportion of 1:4:8 and removing any over lapping mortar at the joints of panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc.required for proper completion of work.Brick on edge flooring with bricks of class designation 7.5 on abed of 12 mm cement mortar, including filling the joints with same mortar, withcommon burnt clay non modular bricks: |
| 475 | Kota stone slab 25 mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, includingrubbing and polishing complete.25 mm thick |
| 476 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement:3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, includingrubbing and polishing complete. |
| 477 | 40mm thick fine dressed stone flooring over 20mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade ofstone.Red sand stone flooring |
| 478 | White sand stone flooring |
| 479 | 40mm thick fine dressed stone decorative flooring over 20mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shadeof stone.Red sand stone decorative flooring |
| 480 | White sand stone decorative flooring |
| 481 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coatof approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) |
| 482 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shapedwashers etc. complete.Hot finished seamless type tubes |
| 483 | Electric resistance or induction butt welded tubes |
| 484 | Providing and fixing mild steel round holding down bolts 'thnuts and washer plates complete. |
| 485 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fasts, tie rods, gratings etc. (when not included in an over all rates) wrought to required form, including supply of steel, bolts, nuts and wastage etc. and theirfixing required for proper completion of the work. |
| 486 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steelprimer.M.S. Tube |
| 487 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. asper direction of Engineer-in-charge.10 x 80 mm |
| 488 | Providing and fixing bolts including nuts and washers complete. |
| 489 | Providing and fixing M.S. rivets of sizes in position. |
| 490 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete |
| 491 | P & L Lime Sand Plaster with lime sand mortar 1:2 (1 Lime : 2 Sand) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, till the shrinkage cracks are disappear. The work is done with all leads as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 daysof previous coat.45mm thick in four coats |
| 492 | P & L Lime Sand Plaster with lime sand mortar 1:2 (1 Lime : 2 Sand) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, till the shrinkage cracks are disappear. The work is done with all leads as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 daysof previous coat.Add extra over item no. 40.5 to 40.6 for Lime plaster work doneover curved/circular masonry work (curved or circular surface.) 45 mm thick in four coats |
| 493 | Making cornice band with ornamental design as per matching with existing design and pattern and as directed by Engineer-in-charge with lime plaster (1 lime : 3 fine sand).Size 150mm wide and 50mm average thick |
| 494 | Size 100mm wide and 50mm average thick |
| 495 | Repairing ornamental plaster works to match with the existingdesign using lime plaster (1 lime putty : 1 surkhi) |
| 496 | Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder) grinding mortar with grinding mill/manually on lime base, on ceiling and all flat surface in two coats. First coat applying 3 mm to 4 mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coatas per traditional practice.(thickness not more than 6 mm.) |
| 497 | Add extra for Lime Kara work (on lime plaster base) other thanflat surface as per traditional practice with all lead & lift with fine finishing complete in all respect on :Domical surface/spherical/domical ceiling. |
| 498 | Curved surface. |
| 499 | Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design(minimum rectangular surface area to be measured). |
| 500 | Providing and laying lime Gola on roofing as per Archaeology practice with lime, Surkhi, brick aggregate 12 to 20mm )1:1:2) and using methi, Gur, Hemp, bhel, etc including beating and temping 100 to 150mm thick as per specifications. Including dismantling of old deteriorated roofing. |
| 501 | Flush/Ruled/Struck or weathered lime pointing 1:2 (1 Lime putty : 2 Surkhi)On Brickwork |
| 502 | Khamira colour washing as per traditional practice to prepare the khamira the lime should be slaked for atleast 7-10 days and regularly it should be stirred by adding curd, gugal, and filteredproperly before application to the surface. |
| 503 | Painting or varnishing on iron works in small areas or new wood wprk with one or cost of ready mixed priming paint and one coat of approved superior quality ready mixed psint of cleasr synthetic varnish including suooly if all materials, labour and T & P etc. required for proper completion of wwork paint to be used should confirm to the S.No. 103 1950. Same as in item No 641 above but for every coat after 1st Coat. Detail ofcost for 650 Sft. Area. |
| 504 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with siliconadditives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @0.90 litre/10 sqm. |
| 505 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete. |
| 506 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required toachieve even shade and colour.Two Coats |
| 507 | Providing & Fixing 50 to 75 mm thick stone chajja in lime sand mortar 1:2 including making gola at junction with wall in lime concrete, 40P• lime mortar & 20mm brick aggregate nominal size graded aggregates, drip course etc complete including 20mm thick plastering in lime Surkhi Mortar 1:2 (1 Lime Putty :2 Surkhi) where ever required, racking of joints, curing, etc complete |
| 508 | Providing new / restoration of decorative Sandstone (Mirzapur/Chunar) brackets as per the original details found on site. The damaged portions of the original bracket to be carefully dismantled without damaging the adjacent areas, and replacing the same with new detail of the same size and design. Sample of the terra cotta bracket to be shown to the Engineer-in-charge for approvals before procuring and fixing the same on the site. Item to include all necessary anchoring details, scaffolding, if required to be paid separately etc complete.Mode of Measurement: Item to be paid only for the part of thebracket made new and not the entire bracket. |
| 509 | Stone Work (Machine cut edges) for wall lining (Veneer Work) upto 10m height, backing filled with grout of average 12mm thick lime mortar 1:2 (1 lime : 2 coarse sand ) including pointing in lime mortar 1:2 (1 lime : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of clamps and pins which shallbe paid separately ):Red sand stone - Exposed face machine cut and table rubbedwith rough backing.40mm thick Stone |
| 510 | White sand stone - Exposed face machine cut and table rubbedwith rough backing.40mm thick Stone |
| 511 | Supply, fabricating, transporting, hoisting and fixing in a position good quality durable Chunar/Mirzapur sandstone/any other type of sandstone in various elements for all level all height. Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in the shade of each element. The stone shall be fine grained and reddish or buff-coloured (locally available of no.1 quality. The work shall be carried out as per attached drawings which different in process of ie carving(manual/by machine), ornamental work, traditional work, figure work, (any other type, any size), CNC cutting, moulding. The carving and moulding work shall be of very good quality and the drawings provided are very preliminary and amount of carving might change during the final execution. The stones to be fized in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and epoxy of Akemi Germany, Anrdex Endura, MYK laticrete or approved make as required and as approved by the Architects. To and fro Transportation charges to CNCestablishment included in the above rates. |
| 512 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade,jali slab without any chamfers etc.Red Sand Stone |
| 513 | White Sand Stone |
| 514 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels.Granite stone slab colour black, Cherry/Ruby redArea of slab upto 0.50 sqm |
| 515 | Area of slab over 0.50 sqm |
| 516 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Redequivalent |
| 517 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group - C |
| 518 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 519 | 4 x 16 sq.mm + 2 x 6 sq.mm. earth wire |
| 520 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 521 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 522 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 523 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 524 | 3 pin 5/6 A socket outlet |
| 525 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 526 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 527 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 528 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PC diffuser. The total power consumption should not exceed 21W (including driver). |
| 529 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W, PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 530 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 531 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required63 A,25KA,FP MCCB |
| 532 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required63 amps TP MCB |
| 533 | 63 amps 4P MCB |
| 534 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 535 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 536 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 537 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 538 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Ground Floor |
| 539 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.Ground Floor |
| 540 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 541 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Both side laminated)(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 542 | (b) Double leaf |
| 543 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 544 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 545 | Z-Section steel windows (openable) |
| 546 | Angle iron door chaukhats 40*40*5 |
| 547 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 548 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 250mm x 16mm. |
| 549 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 250 mm x 10mm |
| 550 | (a) 200 mm x 10mm |
| 551 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :(a) 125mm (For Doors) |
| 552 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 553 | Foundations, footings, bases of columns, etc. for mass concrete |
| 554 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests |
| 555 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 556 | Providing & fixing toilet paper holder C.P. brass |
| 557 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 558 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 559 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 560 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 561 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 562 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 563 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 564 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet)15 mm nominal bore |
| 565 | Providing and fixing uplasticised PVC connection pipe with brass unions :15 mm nominal bore |
| 566 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter |
| 567 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 568 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 569 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 570 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15mm nominal bore |
| 571 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 572 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 573 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 574 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 575 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.15 mm nominal outer dia Pipes |
| 576 | 20 mm nominal outer dia Pipes |
| 577 | 25 mm nominal outer dia Pipes |
| 578 | 32 mm nominal outer dia Pipes |
| 579 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal bore |
| 580 | 25 mm nominal bore |
| 581 | 32 mm nominal bore |
| 582 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall40 mm nominal bore |
| 583 | 50 mm nominal bore |
| 584 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :40mm diameter pipe |
| 585 | 50mm diameter pipe |
| 586 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :40mm diameter pipe |
| 587 | 50mm diameter pipe |
| 588 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 589 | 25mm nominal bore |
| 590 | 32mm nominal bore |
| 591 | 40mm nominal bore |
| 592 | 50mm nominal bore |
| 593 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore |
| 594 | 50 to 80 mm nominal bore |
| 595 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 596 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 597 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia (for rain water) |
| 598 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single Push Fit Coupler110 mm dia |
| 599 | Single tee with door110x110x110 mm |
| 600 | Plain bend 87.5 deg110 mm dia |
| 601 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia |
| 602 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 603 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 604 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:100mm dia SW pipe |
| 605 | Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.75 mm |
| 606 | 110 mm |
| 607 | Exposed on Wall (Soil & Waste Pipe)110 mm |
| 608 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend without door (45°)75mm |
| 609 | 110mm |
| 610 | Bend without door (87.5°)75mm bend |
| 611 | 110mm |
| 612 | Y' Fitting without door75mm |
| 613 | 110mm |
| 614 | Single Tee without door75mm |
| 615 | 110 mm |
| 616 | Single Tee with door75mm |
| 617 | 110 mm |
| 618 | Bend with door (87.5°)75mm |
| 619 | 110 mm |
| 620 | Clean Out Plug (COP)75mm |
| 621 | 110 mm |
| 622 | Reduced 'Y' Fitting without door110mm x 75mm |
| 623 | Reduced Tee with door110mm x 75mm |
| 624 | Coupler75mm |
| 625 | 110mm |
| 626 | Vent Cowl110mm |
| 627 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal32mm dia. Pipe |
| 628 | 50mm dia. pipe |
| 629 | Elbow (45°)32mm |
| 630 | Elbow (90°)32mm |
| 631 | T fitting 32mm |
| 632 | Coupler 32mm |
| 633 | Providing, fixing, jointing and testing , of PVC Multi Floor Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.110mm x 75mm x 50mm/40mm (Toilet) |
| 634 | Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.110mm x 75mm (Toilet & Kitchen) |
| 635 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 636 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 637 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:100 mm diameter |
| 638 | In all kind of soil upto 1.5m to 3.0m. depth |
| 639 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 640 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 641 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 642 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 643 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 644 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 645 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 646 | Providing & fixing 75mm dia vent pipes. |
| 647 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 648 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter |
| 649 | M.D. -2.5- Circular shape 450mm internal diameter |
| 650 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks |
| 651 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as requiredUpto 450 mm sweep |
| 652 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 653 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN |
| 654 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required63 A,25KA,FP MCCB |
| 655 | 63 amps 4P MCB |
| 656 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used.All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.1 Set of 200 Amps TPN Aluminium Bus BarsOUTCOMING125 Amps FP MCCB of 25KA - 1 No63 Amps FP MCCB of 25KA - 3 No40 Amps FP MCCB of 25KA - 3 NoSPARE & SPACE- 2 NoPanel described as above |
| 657 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 658 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 MM thick |
| 659 | ELECTRICALWORKS LUMP SUMD |
| 660 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid |
| 661 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 662 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.Water Cooler Full Steel Body 40 ltr Capacity without Stablizer |
| 663 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 664 | Providing & Fixing in position C.P. Brass coat hook of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P.Brass coat hook |
| 665 | Supply, installation , testing commissioning of PP Mineral filled low noise Soil & Waste system as per EN 12056, with density 1.9 g/cm3. PP mineral(Astolan) filled Low noise system should has a fire classification DIN 4102-B2/EN13501 . Product should have a chemical resistance of pH 2-12 and is a complete sound protection system according to DIN 4109. including with push fit rubber ring sockets all necessary fittings and specials such as Bends, junctions, offsets & vent cowl. Fixing at wall/ceiling level supported by rubber line bracket & hangers etc. duly epoxy coated. Cutting, chases/holes in floors / walls / slab.Compliant with LABC. Weight mass per unit area of DN100MM should not be less than 110.07kg/m3. sound levels of not more than 15dBA as per EN 14366 at a flow rate of 4 l/s.including all core cut ,chases ,cutting making holes in all wall and floor as required complete in all respect. 110mm o/d pipes |
| 666 | 75mm o/d pipes |
| 667 | 50mm o/d pipes |
| 668 | 40mm o/d pipes |
| 669 | Providing fixing, testing and commissioning in position Solfit SWR uPVC PIPE TYPE-B pipe comforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/clean out plugs, clamps /supports/ hangers etc. jointing with PVC Adhesive joints including cutting holes in walls, core cutting in slabs and making good the same. All complete as per specification and direction of E/l.(For rainwater piping) 160mm o/d pipes 110mm o/d pipes |
| 670 | Providing Fixing straight /offset type single body push fit type WC pan connector with factory supplied spring loaded seal guard with integral single mould sealing fins made of flexible EVA body, including bush/adaptor as supplied with the pan connector (if required). |
| 671 | Providing and fixing floor drain (FD) with 50mm/40mm outlet and one 40mm inlet for waste, with SS grating (adjustable height), having 50mm water seal and in-built NRV |
| 672 | Providing and fixing PP/UPVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletSand cast iron S&S as per IS: 3989 |
| 673 | Providing and fixing PP/UPVC grating with Cockroach proof strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. Size 100 mm X 100 mm |
| 674 | Providing and fixing PP/UPVC brass grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement. Size 100 mm X 100 mm |
| 675 | Providing and fixing PP/UPVC extention piece for 100 mm dia floor trap formed out of main pipe with multiple side inlets, suitable for various dia pipes including all fixtures as required complete as per drawing approved sample and direction of engineer in charge. |
| 676 | Providing and fixing cast PP floor clean out plug with suitable insert keys for opening, male threaded joint with threaded socket drip seal to soil / waste pipe as required complete as per drawing approved sample and direction of engineer in charge. |
| 677 | 20 mm nominal dia Pipes |
| 678 | 25 mm nominal dia Pipes |
| 679 | 32 mm nominal dia Pipes |
| 680 | 40 mm nominal dia Pipes |
| 681 | Providing and fixing gun metal valve with C.I wheel of approved quality (screwed end)25 mm nominal dia Pipes |
| 682 | 32 mm nominal dia Pipes |
| 683 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 684 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe |
| 685 | 300 mm dia. R.C.C. pipe |
| 686 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter |
| 687 | 250 mm diameter |
| 688 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With Sewer bricks conforming to IS : 4885 |
| 689 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With Sewer bricks conforming to IS : 4885 |
| 690 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 691 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 692 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 693 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe |
| 694 | 250 mm diameter S.W. pipe |
| 695 | 300 mm diameter S.W. pipe |
| 696 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.50 mm dia nominal bore |
| 697 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :50 mm diameter pipe |
| 698 | Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 699 | Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 700 | ADD GST 18% Extra As per Applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail