| 1 | (A) Safe loading & carriage including Loading-unloading & proper stacking of following store materials from ESC Tripula to site of work. |
| 2 | 13M, ST Pole - SP - 55 Galvanised |
| 3 | ST POLE 11M |
| 4 | TOP CHANNEL |
| 5 | DROPPER CHANNEL 100X50MM |
| 6 | M.S. CHANNEL 100X50X5 M.M. |
| 7 | TEE-OFF CHANNEL |
| 8 | stay set complete |
| 9 | 11 KV \\"V\\" type cross arm 65x65x6 mm, M S Angle |
| 10 | 11 kV Disc Insulator T&C type (45kn) |
| 11 | 11 kV Disc fitting (45KN,T&C) |
| 12 | Polymeric 11KV Pin Insulator |
| 13 | 11 KV 3x185 XLPE Cable |
| 14 | Cable O/D 11 KV 3x185 sqmm J/kit |
| 15 | Straight through cable jointing kit 3x185 sqmm |
| 16 | Earthing of Pole by M S Earthing Rod 20X2500 mm and 6 SWG earthing wire etc |
| 17 | ACSR Rabbit Conductor |
| 18 | ERRECTION |
| 19 | Errection of Double pole by ST Pole 13 Mtr. including digging of Pits & fitting of accessories |
| 20 | Errection of Double pole by ST Pole 11 Mtr. including digging of Pits & fitting of accessories |
| 21 | Errection of ST Pole 11 Mtr. including digging of Pits & fitting of accessories |
| 22 | Digging of pits, fixing nozzling & grouting of stay rods as per RESSPO norms including grouting materials. |
| 23 | Grouting of Poles as per RESSPO norms with grouting materials as per RESSPO Norms. (0.268 Cu.m.each) |
| 24 | Stringing & Sagging of three phase 11 KV line on Rabbit conductor as per RESPO Norms. (As per Direction of Concerned JE & SDO) |
| 25 | Earthing of Pole by M S Earthing Rod 20X2500 mm and 6 SWG earthing wire etc |
| 26 | Laying of 11KV. XLPE cable of size 3X185 mm2 (Double Circut) with GI Wire 6SWG (Provided by Contractor) by Over head through ST Pole |
| 27 | Laying of 11KV. XLPE cable of size 3X185 mm2 in under ground by drilling method through drilling machine with all related works and complete in all respect as per RESSPO norms. |
| 28 | Hanging Cable With all Arangement complete in all respect as per RESSPO norms. |
| 29 | Making of 11 KV 3X185 XLPE Cable Box J/Kit |
| 30 | Fixing/Instalation of Cable Route Marker |
| 31 | Fixing of 11 KV V type Cross Arm 65X65X6 mm MS Angle |
| 32 | Instalation Of Decentralized Materials |
| 33 | PROVIDED BY CONTRACTOR |
| 34 | Clamp for 11 KV \\"V\\" type Cross arm with bolts and nuts |
| 35 | Cantiliver arrangement for 11 KV cable in pole |
| 36 | F-Clamp for Round Pole |
| 37 | Number Plate with clamp and Nut & Bolt |
| 38 | Danger Plate with clamp and Nut & Bolt |
| 39 | G I Barbed Wire |
| 40 | Cable Route Marker |
| 41 | Nut Bolt and washer all sizes Please Enable Macros to View BoQ information |