| 1 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm Dia | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm Dia |
| 2 | Dismantling of existing 200mm Dia Above ground Pipe line | Dismantling of existing 200mm Dia Above ground Pipe line |
| 3 | Installation testing & commissioning of Above Ground Mild steel black pipes of 200mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. | Installation testing & commissioning of Above Ground Mild steel black pipes of 200mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. |
| 4 | Supply, installation testing & commissioning of Above Ground Mild steel black pipes of 200mm Dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC Support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. | Supply, installation testing & commissioning of Above Ground Mild steel black pipes of 200mm Dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC Support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. |
| 5 | Supply, installation testing & commissioning of Above Ground Mild steel black pipes of 150mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. | Supply, installation testing & commissioning of Above Ground Mild steel black pipes of 150mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket, RCC support etc. The above ground newly installed pipe shall be painted as per the enclosed Datasheet / TS. |
| 6 | Supply, installation testing & commissioning of Under Ground Mild steel black pipes of 150mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket etc including excavation and backfilling works. wrapping and coating works shall be done as per enclosed Datasheet / TS. | Supply, installation testing & commissioning of Under Ground Mild steel black pipes of 150mm dia as per IS:1239, Part-I medium grade (for pipes of szies 150mm and below) or IS:3589, Fe410 grade (for pipes of sizes 200mm and above) including work like cutting, welding, grinding etc. with provision of all required fittings like flanges, bends, tees, elbows, reducers, nut-bolts , gasket etc including excavation and backfilling works. wrapping and coating works shall be done as per enclosed Datasheet / TS. |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Dismantling of existing 150mm dia Under ground Pipe line | Dismantling of existing 150mm dia Under ground Pipe line |