| 1 | Pole11 Mtr WPB Pole (approved from TPWODL) |
| 2 | 9 Mtr PSC Pole (approved from TPWODL) |
| 3 | 315 KVA DTR (Plinth Mounted)315 KVA, 11/0.4 KV Transformer (approved from TPWODL) |
| 4 | G.I Channel 100 x 50 x 6mm |
| 5 | G.I Channel 70 x 40 x 6mm |
| 6 | G.I Flat 50 x 6mm |
| 7 | G.I Flat 25 x 6mm |
| 8 | 11 KV A/B Switch 3 pole |
| 9 | 11 KV DO Fuse 3 pole |
| 10 | 11 KV Lightning Arrester |
| 11 | HT Stay Set Complete |
| 12 | HT Stay Insulator |
| 13 | HT Stay Clamp |
| 14 | 7/10 SWG Stay wire |
| 15 | G.I Pipe Earthing, 40mm dia |
| 16 | G.I Bolts, Nuts & Washers |
| 17 | Danger Board |
| 18 | Fabrication and others |
| 19 | LT ACB (400A) (approved from TPWODL) |
| 20 | 1.1 KV 1C 300sqmm XLPE cable (Ar) |
| 21 | 1.1 KV 4C 300sqmm XLPE cable (Ar) |
| 22 | 11 KV 1 core 100 mm2 XLPE insulated AAAC conductor (Unarmaured) for Jumper |
| 23 | Aluminium Socket 300sqmm |
| 24 | 95 Sqmm LT CablePole clamp for AB cable |
| 25 | Dead end Clamp (for ABC) |
| 26 | Suspension clamp |
| 27 | Eye hook for AB cable |
| 28 | Earthing Coil |
| 29 | No.8 G.I wire for earthing |
| 30 | G.I Nuts, bolts (Assorted size) |
| 31 | LT stay set |
| 32 | 7/12 SWG stay wire |
| 33 | LT stay clamp (1.40kg. /pair) |
| 34 | LT Stay insulator |
| 35 | 1.1 KV AB cable (3 x 95 + 1 x 70 + 1 16sqmm) (approved from TPWODL) |
| 36 | DP Structure for DTR & 11 KV O/D MU (CT Ratio-20/5A) & XLPE Cable11 KV 3c x 50sqmm XPLE cable |
| 37 | O/D Jointing kit for 3c x 50sqmm cable |
| 38 | Eye hook for AB cable |
| 39 | Pole clamp for Eye hook for (XLPE AB cable) |
| 40 | 11 KV DO Fuse 3 pole |
| 41 | 2.5 sqmm 10 core control cable |
| 42 | Top channel 100 x 50 x 6mm |
| 43 | Bracing channel 70 x 40 x 6mm |
| 44 | Bracing angle 50 x 50 x 6mm |
| 45 | G.I Flat 50 x 6mm |
| 46 | G.I Flat 25 x 6mm |
| 47 | Fish Plate 50 x 6mm |
| 48 | Lightning arrester (12KV,10KA) Station class |
| 49 | Aluminium Socket 120mm |
| 50 | HT Complete stay set |
| 51 | HT stay clamp G.I (1.9kg/pair) |
| 52 | HT stay insulator (type-c) |
| 53 | 7/10 SWG GI stay wire |
| 54 | G.I pipe for earthing (40mm) |
| 55 | G.I Nuts Bolt & washer |
| 56 | G.I Barbered wire for anticlimbing |
| 57 | Danger Plate |
| 58 | Fabrication & Galvanisation |
| 59 | Civil PartDP Structure for DTR & 11 KV O/D MU (CT Ratio-20/5A) & XLPE CableCancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 60 | Cooping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.2Cu.mtr (per stay) |
| 61 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 62 | Earthing pit for pipe earthing |
| 63 | 315 KVA DTR (Plinth Mounted)Cancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 64 | Concreting ratio 1:1.5:3 (M-20 Grade) with diamention (500 x 500 x 450) = 0.1125 Cu mtr (per pole) |
| 65 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 66 | Earthing pit for pipe earthing |
| 67 | Plinth for ACB |
| 68 | Economic Brick Design Fencing |
| 69 | 95 Sqmm LT CableConcreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.45 Cu.mtr (per pole) |
| 70 | Cooping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125 Cu.mtr (per pole) |
| 71 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) Please Enable Macros to View BoQ information |