| 1 | Pole11 Mtr WPB Pole (approved from TPWODL) |
| 2 | 9 Mtr PSC Pole (approved from TPWODL) |
| 3 | 315 KVA DTR (Plinth Mounted)315 KVA, 11/0.4 KV Transformer (approved from TPWODL) |
| 4 | 100sqmm AAA Insulated Conductor |
| 5 | G.I Channel 100 x 50 x 6mm |
| 6 | G.I Channel 75 x 40 x 6mm |
| 7 | G.I Flat 50 x 6mm |
| 8 | G.I Flat 25 x 6mm |
| 9 | 11 KV Disc Insulator (B & S) Polymer |
| 10 | 11 KV H/W fitting (B & S type) for Disc Insulator Polymer |
| 11 | PG clamp for 100sqmm |
| 12 | 11 KV A/B Switch 3pole |
| 13 | 11 KV DO Fuse 3 pole |
| 14 | 11 KV Lightning Arrestor |
| 15 | HT stay set complete |
| 16 | HT stay Insulator |
| 17 | HT Stay Clamp |
| 18 | 7/10 SWG Stay wire |
| 19 | G.I pipe for earthing (40mm) |
| 20 | G.I Nuts Bolt & washer |
| 21 | Danger Board |
| 22 | Fabrication and others |
| 23 | LT ACB (400A) (approved from TPWODL) |
| 24 | 1.1 KV 1C 300sqmm XLPE Cable (Ar) |
| 25 | 1.1 KV 4C 300sqmm XLPE Cable (Ar) |
| 26 | 11 KV 1core 100sqmm XLPE Insulated AAAC Conductor (Unarmoured) for Jumpering |
| 27 | Aluminium Socket 300sqmm |
| 28 | 95 Sqmm LT AB CablePole clamp for AB cable |
| 29 | Dead end Clamp (for ABC) |
| 30 | Suspension clamp |
| 31 | Eye hook for AB cable |
| 32 | Earthing Coil |
| 33 | No.8 G.I wire for earthing |
| 34 | G.I Nut & Bolts (Assorted size) |
| 35 | LT Stay set |
| 36 | 7/12 SWG stay wire |
| 37 | LT stay clamp (1.40kg. /pair) |
| 38 | LT stay insulator |
| 39 | 1.1KV AB cable (3 x 95 + 1 x 70 x 1 + 16sqmm) |
| 40 | 11 KV DP with Auto Recloser11 KV Auto Reclosure (approved from TPWODL) |
| 41 | 100 sqmm AAAC Covered Conductor |
| 42 | G.I Channel 100 x 50 x 6mm |
| 43 | G.I Channel 75 x 40 x 6mm |
| 44 | G.I Angle 50 x 50 x 6mm |
| 45 | G.I Flat 50 x 6mm |
| 46 | G.I Flat 25 x 3mm |
| 47 | Fish plate 50 x 6mm |
| 48 | Lightning arrester (12KV,10KA) Station class |
| 49 | 11 KV Disc Insulator (B&S) Polymer |
| 50 | 11 KV H/W fitting (B&S type) for Disc Insulator |
| 51 | Aluminium Socket 120mm |
| 52 | PG clamp for 55sqmm AAAC |
| 53 | HT Complete stay set |
| 54 | HT stay clamp G.I (1.9kg/pair) |
| 55 | H.T stay Insulator (type-c) |
| 56 | 7/10 SWG G.I stay wire |
| 57 | G.I pipe for earthing (40mm) |
| 58 | G.I Nuts Bolt & washer |
| 59 | G.I Barbered wire for anticlimbing |
| 60 | Danger Plate |
| 61 | Fabrication & Galvanisation |
| 62 | 11 KV DP with AB Switch (400Amp)11 KV AB Switch (400A) |
| 63 | 100 sqmm AAAC Conductor |
| 64 | Top channel 100 x 50 x 6mm |
| 65 | Bracing channel 70 x 40 x 6mm |
| 66 | Bracing angle 50 x 50 x 6mm |
| 67 | G.I Flat 50 x 6mm |
| 68 | G.I Flat 25 x 3mm |
| 69 | Fish plate 50 x 6mm |
| 70 | 11 KV Disc Insulator (B&S) Polymer |
| 71 | 11 KV H/W fitting (B&S type) for Disc Insulator |
| 72 | Aluminium Socket 120mm |
| 73 | PG Clamp for 55 sqmm AAAC |
| 74 | HT Complete stay set |
| 75 | HT stay clamp G.I (1.9kg/pair) |
| 76 | HT stay insulator (type-c) |
| 77 | 7/8 SWG GI stay wire |
| 78 | G.I pipe for earthing (40mm) |
| 79 | G.I Nuts Bolt & Washer |
| 80 | G.I Barbered wire for anticlimbing |
| 81 | Danger Plate |
| 82 | Fabrication & Galvanisation |
| 83 | 11 KV DP for Outdoor Metering Unit55 sqmm AAAC Conductor |
| 84 | 2.5 sqmm 10 core Control cable |
| 85 | Top channel 100 x 50 x 6mm |
| 86 | Bracing channel 70 x 40 x 6mm |
| 87 | Bracing angle 50 x 50 x 6mm |
| 88 | G.I Flat 50 x 6mm |
| 89 | G.I Flat 25 x 3mm |
| 90 | Fish plate 50 x 6mm |
| 91 | 11 KV V cross Arm (MS 10.2kg each) |
| 92 | 11 KV F clamp (2.9 kg each) |
| 93 | 11 KV Disc Insulator (B&S) Polymer |
| 94 | 11 KV H/W fitting (B&S type) for Disc Insulator |
| 95 | Lightning arrester (12KV,10KA) Station class |
| 96 | PG clamp for 55sqmm AAAC |
| 97 | 11 KV Pin Insulator Polymer |
| 98 | Aluminium Socket 50sqmm |
| 99 | HT Complete stay set |
| 100 | HT stay clamp G.I (1.9kg/pair) |
| 101 | HT stay insulator (type-c) |
| 102 | 7/10 SWG G.I stay wire |
| 103 | G.I pipe for earthing (40mm) |
| 104 | G.I Nuts Bolt & washer |
| 105 | G.I Barbered wire for anticlimbing |
| 106 | Danger Plate |
| 107 | Fabrication & Galvanisation |
| 108 | Civil Part11 KV DP with Outdoor Metering UnitCancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 109 | Cupping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125Cu.mtr (per ple) |
| 110 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 111 | Earthing pit for pipe earthing |
| 112 | 315 KVA DTR (Plinth Mounted)Cancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 113 | Cupping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125Cu.mtr (per pole) |
| 114 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 115 | Earthing pit for pipe earthing |
| 116 | Plinth for ACB |
| 117 | Economic Brick Design fencing |
| 118 | 11 KV DP with Auto RecloserCancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 119 | Cupping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125Cu.mtr (per pole) |
| 120 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 121 | 11 KV DP with AB Switch (400Amp)Cancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 122 | Cupping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125Cu.mtr (per pole) |
| 123 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) |
| 124 | Earthing pit for pipe earthing |
| 125 | 95 Sqmm LT AB CableCancreting ratio 1:1.5:3(M-20Grade) (500mm x 500mm x 1800mm)= 0.45Cu.mtr (per pole) |
| 126 | Cupping ratio 1:1.5:3(M-20Grade) with dimention (500 x 500 x450)= 0.1125Cu.mtr (per pole) |
| 127 | Stay concreting ratio 1:1.5:3 (M-20 Grade) (500mm x 500mm x 800mm) = 0.2 Cu.mtr (per stay) Please Enable Macros to View BoQ information |