| 1 | Excavation in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m, in any kind of soil and making good surfaces, complete all as specified and directed . |
| 2 | Plain cement concrete, M-7.5 (Nominal Mix) type D-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete etc, complete all as specified and directed . |
| 3 | Rolled mild steel work as in posts & struts in fencing using angle, iron or other sections, including cutting tops to shape as directed, drilled holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting and riveting etc and similar work conforming to Fe-290, Gde E-165, complete all as specified and directed.Note : Unit rate is also included locking holes after fixing of barbed wire and welding to bent portion as directed. |
| 4 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete. |
| 5 | Supply only chain link hot dipped galvanised fencing, any type or size |
| 6 | Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410-0 or Fe 310-0, complete all as specified. |
| 7 | Preparation of steel surfaces of any description, over10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 8 | 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring, finished the surface even and smooth without using extra cement complete all as specified. |
| 9 | M&L for preparation of old plastered surface of walls and applying two coat of cement base paint complete all as specified and as directed. |
| 10 | Construction of platform of size 3000 x 2500 x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as per Drg No. CEPZ/C-TD/002/13 complete all as specified and directed by Engr-in-Charge. |
| 11 | Loose filling with 20mm graded crushed stone aggregate, at electrical sub station 4 pole/2 pole structure including brick work for rataining the aggregate complete all as specified & directed. |
| 12 | Earthing complete with Galvanised steel earth plate electrode 60cm x 60cm x 6.30mm thick buried directly in ground to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.50 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt alternatively upto 90 cm and connected with and including GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of GI. 40 mm bore GI pipe light grade from earth plate up to testing point for protection of strip and 20 mm bore GI pipe medium grade with wire mesh and funnel for watering including necessary excavation and earth work PCC chamber (1:3:6) type C-2 with RCC cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part I (2009) complete all as specified.NOTES:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B, 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate of item. (iii) Earth pit chamber ,Name plate and RCC cover shall be painted with red paint over a primer coat and the rate includes in the unit rate of item. |
| 13 | Taking out old unservicable damaged street light fittings and Providing street light fitting of capacity 70 Watt LED Cool white / Warm white fitting,5700 K energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP65 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting etc taking out old U/S damaged street light fittings, complete all as specified and directed. |
| 14 | Disconnecting all incomming /outgoing electric connection carefully from automatic servo voltage stabilizer having capacity 20 to 100 KVA and transport to work shop for repair/servicing, dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internally, including replacement of unserviceable body nut,bolts, washers,top gasket of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting of stabilizer with heat resistant smoke grey synthetic enameled paint including preparation of old rusted surfaces.Note:- Spare parts shall be measured and paid separatly. |
| 15 | Supply only synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 20 to 100 KVA. |
| 16 | Supply only PCB suitable for servo voltage stabilizer having capacity 20 to 100 KVA. |
| 17 | Supply only dimmer motor suitable for servo voltage stabilizer capacity 20 to 100 KVA |
| 18 | Supply only toggle On/Off switches for stabilizer capacity 20 to 100 KVA. |
| 19 | Supply only Volt meter 0-500 Volts, 96mm square type 3 phase 230 volt 50 Hz. |
| 20 | Supply only Ampere meter 0-400 Amp, 96mm square type 3 phase 230 volt 50 Hz with CT of suitable ratio. |
| 21 | Supply only selector switch for volt/Ampere meter suitable for capacity upto 100 KVA. |
| 22 | Supply only gun metal Gate or Glove valve 20 mm for drain out of oil. |
| 23 | Supply only transformer oil of approved quality as per IS having dielectric strength more than 60 KV in 2.5mm gap for filling in voltage stabilizer or for topping up as required and directed. |
| 24 | M&L for rewiding of coils of Voltage Stabilizer of capacity 20 KVA to 100 KVA with super enamelled copper winding wire of appropriate gauge and proper number of turns alongwith insulating material eg leatheroid, paper insulation, cotton tapes, Empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in repairs two side retro reflective sign board of inner size 3 feet x 2 feet with outer frame including stainless steel tubing 40mm bore and length 6 feet for proper support of sign board including foundation with PCC type C-2 1:3:6 (20mm graded aggregate) of size 0.2mx0.2mx0.2m at both side of stainless steel pillars. Sign board printed with green colour Retro radium based colour and laminated English Alphabets with deptt logo on both side as per existing sample, complete all as specified and directed by Engr-In-Charge. |
| 26 | Repair and replacement of Aluminium strip 25 x 3.15mm fixed on roof, pillars, wall etc, including porcelain isolater having not less than 50mm height with screws & saddles and placed at an interval not less than 50cm in such a manner that strip shoulde not touch the wall /roof/pillar surface etc,. for roof conductors and down conductors above ground above roof/wall/pole, complete all as specified. |
| 27 | Supply & fix Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and as directed. |
| 28 | Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw, complete all as specified and directed. |
| 29 | GI strip 25x4mm with saddle and fixing screw etc. for down conductors from terminal block to earthing pit above ground including taking out old, complete all as specified and as directed. |
| 30 | Checking earthing result using earth testing machine for lightening conductors and submitting the results to MES power house duly signed by user complete all as specified & directed. |
| 31 | Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 02 Nos LED light fitting complete with accessories of size length 16 Feet X 1 Feet width outer frame made of angle iron of stand and proper support of sign board including foundation with PCC type C2 1:3:6 (20mm graded aggregate) of size 0.2 m X0.2m X 0.3m at both side of MS Angle pillars. Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv sign board complete all as specified and directed. |
| 32 | Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 01 Nos LED light fitting complete with accessories of size length 4 Feet X 6 Feet width outer frame made of angle iron of stand and proper support for wall at main power house Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv sign board complete all as specified and directed. |
| 33 | Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 02 Nos LED light fitting complete with accessories of size length 22 Feet X 1 Feet width outer frame made of angle iron of stand and proper support of sign board including foundation with PCC type C2 1:3:6 (20mm graded aggregate) of size 0.2 m X0.2m X 0.3m at both side of MS Angle pillars. Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv sign board complete all as specified and directed. |
| 34 | M&L of Copper strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground as specified and directed. |
| 35 | S&F of Air termination , single pointed ,copper rod 12mm dia and 300mm long as specified and directed. |
| 36 | Prepaid energy Meters AC single phase, two wire, 240 volts, 50Hz, 10 to 60 Amps, including addressing issues like malfunctioning displays, damage of parts, internal components failures, faulty connections, keypad not working including taking down old unserviceable meter complete all as directed.Make: HCL PSPB15231110000OC01or equivalent make as approved by GE. |
| 37 | All as per srl item no.28 above but three phase four wire, 415 volts, 50 Hz and 10 to 60 amps rating complete all as directed. Make: HCL or equivalent make as approved by GE. |
| 38 | Static energy Meters AC single phase, two wire, 240 volts, 50Hz, 10 to 60 Amps, including addressing issues like malfunctioning displays, damage of parts, internal components failures, faulty connections, keypad not working including taking down old unserviceable meter complete all as directed.Make: HCL or equivalent make as approved by GE. |
| 39 | All as per srl item no.30 above but three phase four wire, 415 volts, 50 Hz and 10 to 60 amps rating complete all as directed. Make: HCL or equivalent make as approved by GE. |
| 40 | Sub main wiring with two single core PVC insulated unsheathed , 1100 Volts grade, (FRLSH) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor (FRLSH) and connected to common earth dolly including taking down old submain wiring complete all as directed.Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. |
| 41 | Repair to existing wooden/ metal box fitted on site for protection of 2/4 No meter boxes / DB Boxes by dismantling existing unserviceable hinges, doors and locking arrangements and other part etc. and replacing with new hinges, doors, locking arrangements and other parts as required at site and directed by Engr- in- Charge including painting the complete box with two coats of synthetic enamel paint complete all as directed by Engr-in-Charge. |
| 42 | Deduction to be made from BOQ for Sch 'A' Part-II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information |