| 1 | Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and cleaning oil and greasy spots and applying one coat of white wash on walls with mechanical roller, complete all as specified and as directed. |
| 2 | All as per item No. 1 above but one coat of cement base paint on walls surfaces with mechanical roller, complete all as specified and as directed. |
| 3 | All as per item No. 1 above but two coats of cement base paint on walls surfaces with mechanical roller, complete all as specified and as directed. |
| 4 | Preparation of old painted concrete, brick, stone or plastered surfaces of any description not otherwise described over 10 cm width or girth (like kerb stobe etc) and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 5 | Preparation of old plastered or unplastered surfaces of wall by complete removal of existing treatment including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and cleaning oil and greasy spots and Applying Two or more coats of 100% Premium acrylic emulsion paint with mechanical roller having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm on old decorated plastered or unplastered surfaces of walls as directed by Engr-In-Charge. |
| 6 | Preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 7 | Demolition of stones or brick masonry or block walling, built in cement mortar including all quoins, arches etc., but excluding ashlar facing, dressed stone work etc.complete including removal of debris to a distance exc 1.50 KM but n.exc 5 KM, complete all as specified and directed. |
| 8 | Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided for and removal of debris to a distance exc 1.50 KM but n.exc 5 KM outside station boundary complete all as directed. |
| 9 | Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of debris to a distance exc 1.50 KM but n.exc 5 KM outside station boundary complete all as directed. |
| 10 | Providing precast cement concrete M-15, nominal mix, type B-0 (using 12.5 mm graded mechanically crushed stone aggregate) louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame complete all as directed. |
| 11 | Formwork to soffits of suspended slab such as roof slabs, floor slab landings and similar works rough finished surfaces of concrete including supports etc complete all as specified and as directed. |
| 12 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 13 | Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate as) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 14 | Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. |
| 15 | Walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6, complete all as specified and directed . |
| 16 | Plain cement concrete M-15, nominal mix, B-0 using 12.5mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; coping benching, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed. Note :- The unit rate includes for use of form work (straight or curved). |
| 17 | Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and as directed. |
| 18 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement :4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry or cement concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and as directed. |
| 19 | Applying two coats of cement base paint with mechanical roller on newly plastered wall surfaces over one coat of primer including preparation of surface, complete all as specified and directed. |
| 20 | Preparetion of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. |
| 21 | Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. |
| 22 | Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information |