|
| 1 | Schedule-A |
| 2 | Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially provided including removal of rubbish out side the area of Mod Land complete all as specified and directed by Engineer in Charge. |
| 3 | Dismantling floor, stone, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 4 | M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified. |
| 5 | M&L for 75 mm thick cement concrete type D-2 1:4:8 (40mm graded aggreate) as in sub base surface finished even & fair complete all as specified and directed. |
| 6 | M&L for 100 mm thick PCC 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in sub base, complete all as specified and directed. |
| 7 | M&L for PCC (1:2:4) type B1, using 20 mm graded aggregate plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed , complete all as specified and directed. |
| 8 | M&L Providing cement concrete in coping type B-1 ,1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified. |
| 9 | M & L for 100 mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fair using extra cement, complete all as specified. |
| 10 | M&L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 11 | M&L in repair Machine pressed precast concrete coloured interlocking paver block with grey cement and pigment of shape and size approved by Engineer-in-Chrage, confirming to IS 15658-2006 of 60 mm thickness M-35 Grade , complete all as specified and directed. |
| 12 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete. |
| 13 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed. |
| 14 | M&L for painting of two coats of synthetic enamel paint over kerb stone in white/yellow/black shade including priming coat after preparation of new surface/untreated previously laid as per design approved , complete all as specified & directed. |
| 15 | M&L for painting of one coat synthetic enamel paint over kerb stone in white/yellow/black shade including cleaning/preparation of the old surface laid as per design approved, complete all as specified & directed. |
| 16 | S&F Endura colours tiles 300cm X 300cm x 15-20mm homogenious/digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors(Stilt Parking, Car Porch, Driveways, Landscape area, Open to Sky Parking, Podium parking, Ramp Area, Walkways / Pathways / Footpaths) over 15mm thick screed bed in CM 1:4 all as specified and directed. |
| 17 | S&F Endura colours tiles 600cm X 600cm x 15-20mm homogenious/double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors(Stilt Parking, Car Porch, Driveways, Landscape area, Open to Sky Parking, Podium parking, Ramp Area, Walkways / Pathways / Footpaths) over 15mm thick screed bed in CM 1:4 all as specified and directed. |
| 18 | M & L for colored chequered cement concrete tiles of size 300x300x20 - 25 mm thick with grey cement and pigment laid over and including 20mm thick cement screed bed in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floors complete all as specified and directed |
| 19 | Dismantling posts or struts ( wood, steel or RCC) embedded in concrete, brick work etc , any section including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge. Note :- Dismantling of existing galvanised iron steel barbed wire/ chain link fencing shall be measured and paid for separately. |
| 20 | M&L for Plain Cement Concrete Type 1:3:6 type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling mass concrete and posts concrete complete all as specified and directed. |
| 21 | S&F MS Angle iron as in posts and struts and in strips in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (securing with mesh etc including all necessary drilling bolting or reveiting etc and similar works conforimng to Fe 290 (Gde-E-165 quality B). |
| 22 | M&L in repair welded wire mesh/expended metal not exc 4Kg per Sqm, cut to length bent shape required and tying with and including annealed mould steel wire not less than .9mm dia or fixing with galvanised steel stepals supplied and fixed complete to wood or steel members. |
| 23 | S&F in repair chain link MS galvanised fencing, any size or type including line wires, any mesh, standard rails, straining bolts etc including provision of binidng wire all as specified and directed. |
| 24 | S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitting with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 5 to 10 mm etc. |
| 25 | M & L 10 mm dia MS round bar for fixing of chain link fencing with post. |
| 26 | S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts including securing or type at crossings with and provision of galvanised mild steel wire staples or steel pins, etc as directed |
| 27 | S&F in repair 950/ 610/ 450 mm dia concertina coil of reinforced punched (chrome rajor or blade wire) with barbed tap of 0.5 mm thick galvanised steel sheet and core wire of dia 2.5 mm high tensile steel wire incluidng galvanized MS staples/ clips for tying at crossing, complete all as specified and directed by Engineer-in-charge . |
| 28 | Dismantling structural steel work including doors, gates but excluding framed truss etc |
| 29 | S&F mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed (Fe 410-W Gde E-250quality-A). |
| 30 | M&L for Framed work such as grills, gratings etc, for drain, rain water harvesting pit, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars, barred iron door, ladders, framed balusters, walk ways; railings; framed work of water tank, for portions frames and hungs as gates, including pintle hinges, stops hand made sliding bolts, etc and similar work conforming to Fe 290 GDE -E-165, complete all as specified and directed by Engr-in-charge. |
| 31 | M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. |
| 32 | M/L for preparation of old painted steel surfaces and steel based materials of any description not other wise described over 10 Cm width or girth and applying one coat of Synthetic Enamel paint complete all as specified and as directed. |
| 33 | M&L for preparing new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description n. exc 10 cm width or girth. |
| 34 | Cleaning of drainage of various depth including taking off drain cover and re-fixing the same after cleaning, dewatering/excavation of mud deposited in the drain and removing the waste materials to a distance exceeding 100m and deposited where directed by Engr - in - Charge. |
| 35 | M&L for PCC 1:2:4 type B0 using 12.5mm graded aggregate, as in coping, kerbs, water troughs, surface channel, drains and the like including weathering, slightly rounded or chamfered angles and throating incl necessary formwork complete all as specified and directed. |
| 36 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends. |
| 37 | Taking down broken/ unserviceable RCC jali from boundary wall at any height and any position, complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for precast cement concrete type B-0, 1:2:4, using 12.5 mm graded stone aggregate) louvres and Jallies, 25 mm thick including all moulding at any height of bldg/ Compond Walls set in cement sand mortar 1:2 complete all as specified and directed by Engr-in-charge. (Note:- Rate inclusive of all arrangement for scalfolding and safety precautions). |
| 39 | Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including skefolding and all safety measures) |
| 40 | M&L for 15 mm thick rendering in CM 1:6 on brick/concrete surfaces of wall, mixed with integral water proofing compound, the surface shall be cured and allow to dry, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning including preparation of new plastered surface/ previously untreated surface complete all as specified and as directed by Engineer-in-charge. (Whether coat long life) complete all as specified and directed |
| 42 | M&L for washed stone grit plaster on exterior walls in two layers under layer 12mm cement plaster 1:4 (1cement 4 coarse sand) furrowingthe under layer with scratching tool applying cement slurry @ 3kg/sqm top layer 15mm cement plaster 1:1/2:2 ( 1cement 1/2 coarse sand : 2 stone chipping coloured 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing & washing the top layer with brushes & water to expose the stone chipping including taking down of plaster complete all as speacified pattern decided by Engr-in-Charge. (payment for providing grooves shall be made separately).Note:- Top layer of shade shall be of grey cement using colouring pigment & stone chipping of desired colour as approved. |
| 43 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. |
| 44 | M&L for for preparation of old plastered or unplastered decoracted surfaces of wall, pillasters, cornices etc and applying Two coat of exterior emulsion anti fungal paint 100% acrilic smooth exterior paint @ 0.90 Ltr/ 10 Sqm, coloured as approved by GE, including filling all the holes and making uniform smooth surface at any height by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-Charge. |
| 45 | M&L for complete removal of existing treatment from old decorated plasterred surfaces of walls by vaccum based sanding machine complete all as specified, removal of nails etc and filling cracks/ hole with applying wall care putty upto 1 mm thick as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of exterior emulsion anti fungal paint 100% acrilic smooth exterior paint @ 1.67 Ltr/ 10 Sqm, colour as approved by GE, over & including a coat of approved primer by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for preparation of old plastered or unplastered decoracted surfaces of wall, pillasters, cornices etc and applying one coat of plastic emulsion paint, coloured as approved by GE, including filling all the holes/ cracks with wall care putty upto 1 mm thick as required and making uniform smooth surface at any height by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L for complete removal of existing treatment from old decorated plasterred surfaces of walls by vaccum based sanding machine complete all as specified, removal of nails etc and filling cracks/ hole with wall care putty upto 1 mm thick as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of plastic emulsion paint, colour as approved by GE, over & including a coat of approved primer by using smart periodical methodology/ auto roller, complete all as specified and directed by Engr-in-Charge. |
| 48 | M&L for preparation of old plastered or unplastered decorated surfaces of walls, chajjas, soffits of chajja, slab projection and cornices spoiled by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots by scraping with vaccum based sanding machine, washing with water all as specified, filling cracks/ hole with wall care putty and applying one coat of cement base paint by smart periodical methodology/ auto roller, complete in all respect as specified and directed by Engr-in-charge. |
| 49 | M&L for preparation of old decorated steel and steel based surfce of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint, complete in all respect as specified and directed by Engr-in-Charge. |
| 50 | M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite over & including 15 mm thick screed bed in CM 1:4 including grinding, moulding rounnding and polishing bedding as in plateforms, steps or in similar works etc complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for granite 20 mm thick machine cut in skirting/dado, wall cladding, on Columns and similar works over and including 10mm thick rendering in CM 1:4 on stone/brick masonry surfaces, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete. |
| 52 | Demolition of brick work or stone/boulders masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etac but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge. |
| 53 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mena radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge |
| 54 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement). |
| 55 | Demolition of RCC of any description and in any position not otherwise specifecally provided for(for manhole covers), drain slab etc complete. |
| 56 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately. |
| 57 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 58 | M&L RCC M-20 (Design mix) using 20mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 59 | Formwork rough to the sides and soffits of beams and similar works complete all as specified and directed. |
| 60 | M&L RCC M-20 (Design mix) using 20mm graded aggregate as in beams cantilevers,bressummers lintle over 1.5m span complete all as specified and directed. |
| 61 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 62 | Ditto- all as per item No 10 above but Mild steel bars of 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 63 | M&L 12mm thick rendering on brick/concrete surface in CM 1:6 finished even and fair without using extra cement. |
| 64 | M&L preaparing plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 65 | De-silting and cleaning of existing storm water drain by removing silt, soil, vegetation growth and removing of rubbish from the premises for cleaning of drains, complete in all respect as specified and directed by Engineer-in-Charge. |
| 66 | De-silting & cleaning of old Rain water harvesting Pit including removing of all silt, Soil, vegetation growth, removing of aggregate of different grading layer wise maintaining the grading, cleaning by washing, straining to maintain grading layerwise and refilling the same as per existing pattern after necessary repairing to pit structure as required under respective items hereinafter, and removing rubbish from the premises complete all as specified and as directed by Engr-in-Charge. |
| 67 | S&F in repair Precast Cement concrete perforated drain cover of size 900 mm x 500mm x 75 mm thick srounded with steel strip 75x1.5mm Reinforced as per manufactiurer's design in Munufactured proccess laid over existing drain complete all as specified and as directed by Engr-in-Charge. Notes: - (i) Contractor shall provide PV alongwith manufacturer test certificate of drain cover. |
| 68 | S&F in repair Precast Cement concrete perforated drain cover of size 1100 mm x 500mm x 75mm thick srounded with steel strip 75x1.5mm Reinforced as per manufacturer's design in Munufactured proccess laid over existing drain complete all as specified and as directed by Engr-in-Charge. Notes:- (i) Contractor shall provide PV alongwith manufacturer test certificate of drain cover. |
| 69 | S&F in repair Precast Cement concrete perforated drain cover of size 600mm x 450mm x 75mm thick srounded with steel strip 75x1.5mm Reinforced as per manufacturer's design in Munufactured proccess laid over existing drain complete all as specified and as directed by Engr-in-Charge. Notes: - (i) Contractor shall provide PV alongwith manufacturer test certificate of drain cover. |
| 70 | S&F in repair Precast Cement concrete 600/710 mm dia with 75 mm thick circular factory made manhole covers rounded with steel strip 75x1.5mm Reinforced manufactured with M-30 grade or concrete vibro compaction process, complete all as per manufacture's instruction to take load as specified. i.e. 20 MT per heavy duly when tested as per IS-12592).Notes: - (i) Contractor shall provide PV alongwith manufacturer test certificate of drain cover. |
| 71 | Cleaning of blocked rain water pipe of dia 100-150 mm near path and drain and rubbish of the premises complete all as specified and directed by Engr-in-charge. |
| 72 | Removal of debris/ malwa to a distance exc 10 Km but n exc 15 Km and depositing out side the MoD land, as per NGT norms. |
| 73 | Note :- The amount of Rs 95413.50 against Schedule of Credit on Srl Page 146 shall be deducted from the total amount quoted against Sch 'A' Please Enable Macros to View BoQ information |