| 1 | Taking out centrifugal pumping set 30 HP, three Phase from foundation, transporting to workshop opening for inspecting all parts to identify defective parts cleaning and keeping aside serviceable parts in safe custody, rewinding with super enamelled copper wire as per existing size and general servicing/overhauling of pump , electric motor & Re-assembling of motor and pump, transporting back to pump house and connecting with pipes, making electric connections and testing for performance complete all as directed. (Note : Replacement of parts shall be measured separately) |
| 2 | Supply and fixing in replacement of Ball bearing suitable for 30 HP motor complete all as spccified and directed. Make -NBC/SKF |
| 3 | Supply and fixing in replacement of Gun Metal shaft bush for 30 HP pump with lock key complete all as specified and directed. |
| 4 | Supply and fixing in replacement Impeller for 30 HP pump complete all as specified and directed. |
| 5 | Lifting and taking out existing open-well Submersible pump set of capacity up to 15 HP for carrying out repairs including reinstallation in UG Sump /Water tank all as directed. |
| 6 | Lifting and taking out existing open-well Submersible pump set of capacity up to 5 HP for carrying out repairs including reinstallation in UG Sump/Water tank all as directed. |
| 7 | Repair/overhauling of verticle turbine Submersible pump set of capacity upto 15 HP including replacement of defective parts, opening, cleaning, oiling, greasing, and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines mechanically and electrically with starter complete all as specified and directed. (Note : Replacement of parts shall be measured separately) |
| 8 | Rewinding of 15 HP submersible pump motor with super enamelled copper wire of existing gauge, turns, providing sleeve, varnishing with 'E' class insulation varnish including cutting and taking out existing burnt out winding, cleaning complete including testing after rewinding at user site and complete testing all as directed. |
| 9 | S&F in Repair/replacement of Star Delta starter for pump motor 15.0 HP capacity at user site and complete testing all as directed. (Make: L&T/Havells/Standard) |
| 10 | S&F in repair/replacement of 15 HP pump bearing 6207, 6208 at user site and testing complete all as directed. Make -NBC/SKF |
| 11 | S&F in replacement of water seal for water leakage at user site and and testing complete all as directed. |
| 12 | S&F in replacement bush of suitable size for 15 HP submersible pump motor complete all as directed. |
| 13 | S&F in replacement of preventor system supply 3 phase, 415V, AC as per existing specification at user site and and testing complete all as directed. |
| 14 | Replacement of gaskit suitable for upto 80mm dia pipe line with 4 Nos nuts, bolts and washer complete as per existing size. |
| 15 | Complete re-assembling & testing of submersible pump with motor and reconnecting with GI pipe upto 100mm dia complete all as directed. |
| 16 | Repair/overhauling of open-well Submersible pump set of capacity up to 5 HP including replacement of defective parts, opening, cleaning, oiling, greasing, and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines mechanically and electrically with starter complete all as specified and directed. (Note : Replacement of parts shall be measured separately) |
| 17 | Rewinding of motor with super enamelled copper wire with existing gauge, turns, providing sleeve, varnishing with 'E' class insulation varnish including cutting and taking out existing burnt out winding, cleaning complete including testing after rewinding copper at user site and complete testing. |
| 18 | S&F in Repair/replacement of Star Delta starter for pump motor 5 HP capacity at user site and complete testing. (Make: L&T/Havells/Standard) |
| 19 | S&F in repair/replacement of pump bearing 6207, 6208 at uses site and complete testing. Make -NBC/SKF |
| 20 | S&F in replacement of water seal for water leakage at user site and complete testing. |
| 21 | S&F in replacement bush of suitable size of 5 HP submersible pump motor complete all as directed. |
| 22 | S&F in replacement of preventor system supply 3 phase, 415V, AC as per existing specifications at user site and complete testing. |
| 23 | Replacement of gaskit suitable for up to 50mm dia pipe line with 4 Nos nut, bolts and washer complete as per existing size. |
| 24 | Complete reassembling and testing of submersible pump and motor 5 HP and reconnecting with GI pipe of 40mm dia medium grade. |
| 25 | S&F in replacement of 6.00 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 3 core with and including PVC concealed conduit and providing proper connection from star delta starter to pump motor 15HP capacity at user site and testing complete all as directed. |
| 26 | S&F in replacement of 4.00 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 3 core with and including PVC concealed conduit 20mm dia and providing proper connection from star delta starter to pump motor 5HP capacity at user site and testing complete all as directed. |
| 27 | S&F in replacement of 2.5 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 2 core with and including PVC concealed conduit 20mm dia and providing proper connection from star delta starter to pump motor 5HP capacity at user site and testing complete all as directed. |
| 28 | Opening, dismantling and taking out of unserviceable self priming monoblock pump 0.5 HP/ 1HP /2 HP assembly complete with motor and replacement of unsv parts any type complete all as specified and directed. |
| 29 | Repair/overhauling of self priming monoblock pump 0.5 HP /1.00HP /2.00 HP, 220 Volts, including replacment of defective parts, opening, cleaning, oiling, greasing, rewinding and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines with mechanically and electrically with starter complete all as specified and directed. |
| 30 | Taking out and replacement of unserviceable PVC automatic pressure control assembly of self priming monoblock pump 0.5/1.00/2.00 HP, 220 Volts, single phase and reinstallation at same position including testing complete all as specified and directed. |
| 31 | Supply and fix in replacement self priming monoblock pump 1 HP, 220 Volts, including connecting with existing pipe line with mechanically, electrically and testing complete all as specified and directed. |
| 32 | Supply and fix in replacement self priming monoblock pump 3 HP, 220 Volts, including connecting with existing pipe line with mechanically, electrically and testing complete all as specified and directed. |
| 33 | Taking up or down steel tubing pipes of 15mm dia with connection from trenches, ceiling, floor/ walls etc including cleaning for refixing or removing from site complete all as specified and directed. |
| 34 | Supply and and fixing in replacement of 15/20mm Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as spceified and directed. |
| 35 | Mild steel galvanised iron water tubing 15mm bore with screwed & socket joints, medium grade, galvanised, with all fittings fixed to wall or laid in floor, complete all as specified and directed. |
| 36 | Repair/overhauling of self priming monoblock pump 5 HP, 220 Volts, including replacment of defective parts, opening, cleaning, oiling, greasing, rewinding and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines mechanically and electrically with starter complete all as specified and directed. (Note : Replacement of parts shall be measured separately) |
| 37 | Opening, taking out and replacement Impeller suitable of 5 HP monoblock pump with gaskit and thrust washer (as per existing size) complete all as directed. |
| 38 | S&F in replacement of pump bearing 6207, 6208 suitable of 5 HP monoblock pump complete all as directed. |
| 39 | S&F in replacement of bush suitable of 5 HP monoblock pump complete all as directed. |
| 40 | S&F in replacement of motor fan, outer dia suitable of 5 HP monoblock pump complete all as directed. |
| 41 | S&F in replacement of preventor system suitable of 5 HP monoblock pump complete all as directed. |
| 42 | S&F in replacement of Star Delta starter suitable of 5 HP monoblock pump and testing complete all as directed. |
| 43 | Replacement of gaskit suitable of 5 HP monoblock pump complete with 4 Nos nut bolts and washer as per existing size all as directed. |
| 44 | Complete reassembling & testing of monoblock Pump & motor 5.0 HP and reconnecting with GI pipe 40mm dia complete all as directed. |
| 45 | Repair & replacement of unservicable Brush cutter with opening, dismantling for taking down under mentioned spares parts/assemblies. |
| 46 | Replacement of Stainless steel treaming rod with complete set. |
| 47 | Replacement of starting switch complete. |
| 48 | Replacement of Oil seal kit complete. |
| 49 | Replacement of Ball bearing complete. |
| 50 | Replacement of treaming wheels complete |
| 51 | Repair of piston kit complete |
| 52 | Replacement of crank shaft complete |
| 53 | Replacement of Clutch plate complete |
| 54 | Replacement of Recoil Startor complete |
| 55 | Replacement of Carburator complete |
| 56 | Replacement of Plug complete |
| 57 | Replacement of Filter complete |
| 58 | Replacement of Double shoulder belt complete |
| 59 | Repair of unservicable electric Brush cutter with opening, dismantling, rewinding including replacement of all unsv parts/assemblies complete all as directed. |
| 60 | Repair of Chlorination Plant including opening, dismantling, taking out and supply & fixing in replacement of motor, inner tank and undermentioned spare parts including installation, testing complete all as specified and directed. |
| 61 | Measuring glass holder Pt. No. 33340 |
| 62 | Clamp screw for glass Pt. No. 28804 |
| 63 | Teflon Vent tube 3/8 |
| 64 | Diapharagm front Plate Pt. No. M-369 |
| 65 | Diapharagm Back Plate Pt. No. B-126 |
| 66 | Plant Connecter Assembly(SS) Pt. No. M-211 |
| 67 | Gas Pressure Guage B-314 |
| 68 | Inlet Valve G5/8 Pt. No. 29714 |
| 69 | Supply and fixing round shape water tank lid 1.25mm thick aluminium power coated stainless steel long body locking plate a small pack containing, a thick stainless steel centre bolt, a small nylon nut and a thin couple bolt capacity for for 500/1000/2000 litres capacity tanks including taking down existing PVC tank complete all as specified & directed. |
| 70 | Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer on steel surface of pipes, MS items etc including preparation of old painted surface all as specified and directed. |
| 71 | Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer on Motors of different capacity including pipe connections, MS items etc including preparation of old painted surface all as specified and directed. |
| 72 | Material and labour for two coats of synthetic enamel paint welded wire mesh surfaces of sedimentation tank including connected angle iron frame all as specified and directed. |
| 73 | Repair/overhauling of electric induction (backwash pump) of capacity up to 30 HP including replacment of defective parts, opening, cleaning, oiling, greasing, rewinding and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines mechanically and electrically with starter complete all as specified and directed. |
| 74 | Repair/overhauling of electric induction of capacity up to 2HP including replacment of defective parts, opening, cleaning, oiling, greasing, rewinding and re-fitting with proper allignment including testing comissioning and connecting with existing pipe lines with mechanically and electrically with starter complete all as specified and directed. |
| 75 | S & F in replcement cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 3.5 core, complete all as specified and as directed. |
| 76 | Supply & fixing of contact relay 415V, three phase suitable for 15 HP motors as per existing specification complete all as specified and directed. |
| 77 | Supply & fixing of contact relay 415V, three phase suitable for 5.0 HP motors as per existing specification complete all as specified and directed. |
| 78 | Supply & fixing of contact relay 415V, three phase suitable for 30.0 HP motors as per existing specification complete all as specified and directed. |
| 79 | M&L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 80 | Mild steel Plates (plain or chequered 3mm thick) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding, complete all as specified. |
| 81 | M&L for Brick masonry valve pit of size 120x120x120cms (internal dimension) with earth work in any type of soil, plain cement concrete M-10 type C-2 as in foundation, brick work in cement mortar 1:6 (01 cement : 06 coarse sand) 23cms thick, 15mm thick plaster in cement mortar 1:4 (01 cement : 04 coarse sand) internally and externally flush pointed in same mortar as the work proceeds flooring shall be 40mm thick in plain cement concrete M-15 (Nominal mix) laid over 75mm thick hard core top cover shall be made out of mild steel sheet 3.15mm thick fixed in angle iron frame made out of angle size 40x40x6mm with two number of hinges on one side and locking arrangement at other side with 50mm pad lock complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 82 | Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed. |
| 83 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 84 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified |
| 85 | M&L for 400mm Cast iron water mains pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as dirrected. |
| 86 | M&L for 250mm dia Ductile Iron spun pipes K9 with internal cement mortar lining and external Zinc coating with finishing layer of Bitumen, manufactured, tested and duly marked in strict accordance with and confirming to IS:8329/2000 (as per indian amendement) in any length in trenches complete all as spccified and directed Engr--in-Charge. |
| 87 | M&L Cast iron/ductile iron fittings for spigot and socketed pipe i.e. bends (any type radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) all sockets or socker and spigot collars, caps and plugs up to 200-300mm dia all as specified. |
| 88 | M&L Cast iron/ductile iron fittings for flanged pipe i.e. bends (any type radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) all sockets or socker and spigot collars, caps and plugs up to 200-300mm dia all as specified. |
| 89 | M&L Cast iron sluice valve 400 mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works will be measured and paid for separately.) all as specified and as directed by Engr-in-Charge. |
| 90 | M&L Cast iron sluice valve 250 mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works will be measured and paid for separately.) all as specified and as directed by Engr-in-Charge. |
| 91 | M&L Cast iron sluice valve 150 mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works will be measured and paid for separately.) all as specified and as directed by Engr-in-Charge. |
| 92 | M&L Cast iron sluice valve 100 mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works will be measured and paid for separately.) all as specified and as directed by Engr-in-Charge. |
| 93 | M&L Cast iron sluice valve 80 mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works will be measured and paid for separately.) all as specified and as directed by Engr-in-Charge. |
| 94 | M&L for attending the complaint for any leakage of main CI/DI/GI pipe line of upto 400 mm dia for repair/leakage including tightening of joints/nuts/repair of valves etc. complete all as directed by Engr in Charge. |
| 95 | M&L for Cleaning of surrounding area near water supply pipe lines, motors including plants and vegetation complete all as specified and as directed by Engr in charge. |
| 96 | S&F bracket made of 25 mm dia GI pipe light grade ISI marked 1.20 mtr long bent to shape with 2 Nos MS clamp duly painted with two coat of aluminium paint over one coat of red oxide, made of 32x5mm FI with nuts, bolts and washers suitable for off size HT/LT poles including dismantling existing bracket all as specified and directed. |
| 97 | Supply and fixing in replacement LED street light fitting 72 watt complete with Pressure die cast aluminum housing enclosed with Heat resistant glass cover in frame complete with IP 66 protection and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting on pole complete all as directed. |
| 98 | Supply and fixing in replacement on Pole/Wall Flood light fittings for use with LED lamps, 120 watts CW (125LM/watts) with IP 66 made of high pressure die cast aluminium eith toughened glass potted driver, 230 Volt, with high quality lenses & reflector, complete with control gear and all accessories including lamp, complete all as specfied and directed. |
| 99 | Supply and fixing in replacement LED street light fitting 45 watt complete with Pressure die cast aluminum housing enclosed with Heat resistant glass cover in frame complete with IP 66 protection and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting on pole complete all as directed. |
| 100 | Repair and replacement of existing fountain including GI tubing, electric motor, nozzles to spread the water all around in an aesthatical appearance and complete all as specified and as directed by Engr-In-Charge. |
| 101 | S&F in replacement of MCCB TP 160A, 415V, 36 KA complete all as directed. |
| 102 | S&F in replacement of MCCB TP 100A, 415V, 16 KA complete all as directed. |
| 103 | S&F in replacement of MCCB TP 63A, 415V, 16 KA complete all as directed. |
| 104 | Supply only Best quality bleaching powder Grade A, ISI marked for water treatment purpose Make: DCM Shri Ram complete all as specified and as directed by Engr-in-Charge. |
| 105 | Supply only Ferric alum solid cake type material best quality for water treatment purpos complete all as specified. |
| 106 | Supply only Best quality AQUA FIT(Calcium based granular disinfectant for water treatment, more stable than chlorine gas,and stronger than bleaching powder) in 45Kg packing plastic drum. Make: Declibac/Purichlor as approved by E-in-C complete all as specified and as directed by Engr-in-Charge. |
| 107 | Dismantling chain link fencing of any description from post including line wire etc; complete all as specified and directed. |
| 108 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 109 | M&L for PCC 1:3:6 type C2 Cement concrete (using 40 mm graded crushed stone) as in foundations, filling and mass concrete etc complete all as specified and directed by Engr-in-Charge. |
| 110 | S&F Mild steel work as in fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge. |
| 111 | S&F for Mild steel 10 mm dia neck and length exc. 5 cm but n. exc. 10 cm screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut Complete all as specified and directed. |
| 112 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 113 | Supply only Chain link hot dipped MS galvanisd fencing, any size or type complete all as specified. |
| 114 | M&L for applying two coats of synthetic enamel paint on steel surface of any description over 10 cm width or girth, not otherwise described, including prepration of new steel surface over a coat of red oxide complete all as specified and directed. |
| 115 | Deduction to be made from BOQ for Sch 'A' Part - II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information |