| 1 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level reinforcement cut to facilitate demolitioncomplete all as specified and directed. |
| 2 | Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | M&L for Brick work with sub class ‘B’ old size bricks well burnt, straight or curved on plan exc 6m mean radius built in CM(1:4) ccomplete all as specified and directed. |
| 4 | Rendering 15 mm thick in cement mortar (1:4) on brick surface and finising plastered surface with using extra cement, complete all as specified and directed. |
| 5 | Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level complete all as specified and directed. |
| 6 | M&L for PCC type C2 1:3:6 (40mm graded aggregate) as in surface of drains complete all as specified and directed. |
| 7 | M&L for PCC type B0 1:2:4 (20mm/12.5 mm graded aggregate) as in haunching including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 8 | M&L for PCC type C1 1:3:6 (20mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 9 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitered /stopped ends etc complete all as specified and directed. |
| 10 | M&L for providing pre cast reinforced cement conccrete type B1,1:2:4 (20 mm grade Aggregate) in cover slabs and similar articles with plane faces set in cement mortar 1:4 complete all as specified and directed.. |
| 11 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed. |
| 12 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 13 | S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 110mm bore pipes complete all as specified and directed. |
| 14 | S & F for PVC (SWR) bends any radius, 110mm bore complete all as specified and directed. |
| 15 | S & F for PVC (SWR) Single T equal or unequal, 110mm bore complete all as specified and directed. |
| 16 | S & F for PVC (SWR) Single Y equal or unequal, 110mm bore complete all as specified and directed. |
| 17 | S & F Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges of thickness 1.25mm of dia 150mm complete all as specified and directed. |
| 18 | S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 19 | M&L for applying two coat of Synthetic enamal paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation of surfaces complete all as specified and directed. Please Enable Macros to View BoQ information |