| 1 | Dismantling of plain or corrugated sheeting of any pattern compete all as specified and directed. |
| 2 | S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screwscompete all as specified and directed. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws compete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for compete all as specified and directed. |
| 5 | S&F steel work in tubular section for purlin/rafters etc including special shaped washer etc. complete using induction butt welded tubes conforming to I.S. 1161-1998 grade St- 240 compete all as specified and directed. |
| 6 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc gde Fe-410 W (Gde E- 250) quality A compete all as specified and directed. |
| 7 | M&L for applying two coat of Synthetic enamal paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation compete all as specified and directedcompete all as specified and directed. |
| 8 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, cooler stands (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor compete all as specified and directed. |
| 9 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets compete all as specified and directed. |
| 10 | S&F aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of distemper oil emulsion complete all as specified and directed. |
| 11 | S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing compete all as specified and directed. |
| 12 | 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing compete all as specified and directed. |
| 13 | Taking down chowkats or frame, n. exc 1.5 sqm each with shutters (without taking off shutter from the frame) compete all as specified and directed. |
| 14 | Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exe 1.50 & n.exc. 4 sqm in each complete all as specified and directed. |
| 15 | S&F powder coated aluminium anodised frame for doors, windows etc with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 16 | S&F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. compete all as specified and directed. |
| 17 | Supply and fixing of aluminium sliding window with powder coating (minium thickness of powder coating 50 micron) including following components / specification complete all as specified and directed. (i) Thickness and weight per metre length of aluminium frame and section of shutter all as shown on drawing. (ii) All vercal/ horizontal joint shall be of extruded aluminium section so as to avoid any play between jointed members. (iii) all other accessories such as jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, srews, etc. (iv) Stainless steel wire cloth, 036 mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples, etc. (v) Sheet glass 4 mm thick selected quality tinted/black glass and glazing with oil putty or fixed with wooden beads in square not exceeding 0.5 Sqm in each pane (vi) Rest all as specified in drawing no CEZ/2015/TD/007 Sheet no 1R/5, 2R/5, 3R/5, 4R/5, 5R/5. Note :- Grill shall be measured and paid separately. |
| 18 | Supply & fixing Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement compete all as specified and directed. |
| 19 | Supply only sheet glass ordinary quality,in squares n. exc. 0.5 SQM each 4.80 mm thick compete all as specified and directed. |
| 20 | S & F pressed steel frames for door 105mm X 60mm with revates including necessary fittings lugs, hings, lock strike plate, etc complete as specifieds, supplied and fixed compete all as specified and directed. |
| 21 | S&F pressed steel door frame 125x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates comlete as specified and directed (pcc filling of hollow section measured and paid seprately) compete all as specified and directed. |
| 22 | M&L for PCC 1:3:6, C-1 (using 20 mm graded stone aggregate) as in bed blocks for inserting holdfast/ filling of steel frame, etc including necessary form work compete all as specified and directed. |
| 23 | S&F 30mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides Ditto, but with particle board core compete all as specified and directed. |
| 24 | S & F 35mm thick, 2nd class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a) compete all as specified and directed. |
| 25 | M & L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer ccompete all as specified and directed. |
| 26 | S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples compete all as specified and directed. |
| 27 | Supply and fix butt hinges 100mm long cold rolled medium weight complete all as specified and directed. |
| 28 | Supply and fix for 150mm long aluminium handles, cast type, anodised complete all as specified and directed. |
| 29 | Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 30 | S&F in Repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of ocver plate 140mm, fixed in floor compete all as specified and directed. |
| 31 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises compete all as specified and directed. |
| 33 | M & L for 25 mm thick PCC type B0 1:2:4 (using 12.5 mm graded stone aggregate) as in leveling layer compete all as specified and directed. |
| 34 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. |
| 35 | M&L for Non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm (400X400X7mm) in floor, over and incl 20mm thick screed bed in CM 1:4 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade compete all as specified and directed. |
| 36 | M&L for glazed ceramic tiles in vertical surface 300x450x7mm thick in dado over and incl 10mm thick screed bed in CM 1:4 on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shadecompete all as specified and directed. |
| 37 | M & L for 75 mm thick plain cement concrete 1:3:6, type c-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with bitumastic filling in proportion of bitumen and sand (1:2) compete all as specified and directed. |
| 38 | M & L for for 100 mm thick PCC type D-2 1:4:8 ( using 40mm graded stone aggregate) as in sub base compete all as specified and directed. |
| 39 | M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 40 | Material and labour for Machine cut pre polished kota stone slab flooring 20 to 25mm thick size not less than 22\\" x 22\\" laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20mm thick cement screed bed in cement mortar 1:3 including rubbing and mirror polishing complete all as specified and directed. |
| 41 | Material and labour for pre polished kota stone slab 20 to 25mm thick in riser of steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 10mm thick rendering in cement mortar 1:4 including cutting, moulding outer edges, rubbing and mirror polishing complete all as specified and directed. |
| 42 | Dismantling of stone slabs or tiles of any description or thickness as in floors, pavings, aprons, pathway etc laid dry or laid dry and pointed complete all as specified and directed. |
| 43 | S&F Machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment laid over sand cushing complete all as specified and directed.Note :- Sand cushioning will measured and paid seperately. |
| 44 | Supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 cm thick in each layer compete all as specified and directed. |
| 45 | M&L for Pre-cast (Factory casted) cement concrete Kerb stone casted in PCC (1:2:4) Type B-1 using 20mm graded stone aggregates with plan or interlocking joints (as directed) with solid blocks, exc. 10 cm in width and setting and jointed in cement mortar 1:6, complete all as specified and directed. |
| 46 | M & L for preparation of kerb stone, new un-treated concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint in black and white colour over a coat of primer complete all as specified and directed. |
| 47 | M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, over and including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 48 | Taking up or down 15mm steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 49 | Refixing 15mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) compete all as specified and directed. |
| 50 | S & F steel tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors compete all as specified and directed. |
| 51 | Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed. |
| 52 | Refixing 20mm old steel tubing and connection in new or old position (wall, ceiling, floors, etc.) compete all as specified and directed. |
| 53 | S & F steel tubing 20 mm bore medium grade galvanised with all fittings and fixed complete to wall, ceilings or laid in floors compete all as specified and directed. |
| 54 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing and making good , cutting not exc 10cm girth compete all as specified and directed. |
| 55 | S & F in repairs 15 mm bore Bip taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed compete all as specified and directed. |
| 56 | S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges compete all as specified and directed. |
| 57 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc compete all as specified and directed. |
| 58 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement compete all as specified and directed. |
| 59 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement compete all as specified and directed. |
| 60 | M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceilings (sunshade, chajja etc) and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 61 | M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 62 | M & L for applying two coats of distmper oil emulsion over coat of primer including wall care putty on walls after preparing surfaces of walls on newly plastered wall surfaces including preparation of surfaces compete all as specified and directed. |
| 63 | M&L for preparation of new surfaces, scrubing down, washing etc from walls by scrapping with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted) with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfacesincl 1mm thick plaster of paris putty, using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and will execute the same work by authorised applicator as mentioned in PS and acessories complete all as specified and directed. |
| 64 | M&L for complete removal of exisiting treatment of wall and applying two coat of oil bound distemper over one coat of primer over and incl over 3mm thick wall care putty to make the surface even and smooth compete all as specified and directed. |
| 65 | M&L for complete removal of existing treatment inclpreparation of old surfaces, scrubing down, washing etc from walls by scrapping with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc. and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted) with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfacesincl 1mm thick plaster of paris putty, using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and will execute the same work by authorised applicator as mentioned in PS and acessories complete all as specified and directed. |
| 66 | Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles compete all as specified and directed. |
| 67 | Material & Labour for Brick work with sub class ‘B’ well burnt old size bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) compete all as specified and directed. |
| 68 | M&L for half thick brick work with sub class 'B' bricks well burnt straight or curved on plan exceeding 6m mean radius with old size bricks locaaly available built in cement mortar 1:4 compete all as specified and directed. |
| 69 | M&L for PCC 1:3:6 type C-2(40mm grade stone aggregate) as in surface channels and drains etc incl form work complete all as specified and directed. |
| 70 | M&L for PCC 1:2:4 type B-1(20mm grade stone aggregate) as in coping ,water troughsand the likes incl weathering slightly rounded and chamfered and throating etc complete all as specified and directed. |
| 71 | Extra for forming fair finished surfaces of drain or channels, inner girth 25 cms, using extra cement including forms, moulds mitred/ stopped ends etc., compete all as specified and directed. |
| 72 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement compete all as specified and directed. |
| 73 | M&L for Neeru finish to plastering compete all as specified and directed. |
| 74 | M&L for providing pre cast reinforced cement concrete type B1,1:2:4 (20 mm grade Aggregate) in landings and similar articles with plane faces set in cement mortar 1:4 compete all as specified and directed. |
| 75 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT bars compete all as specified and directed. |
| 76 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) compete all as specified and directed. |
| 77 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in trenches or in floors complete all as specified including dismantling of PCC & taking out old unserviceable 110mm bore PVC pipe with fittings & making good disturbed area complete all as specified and directed. |
| 78 | S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 110mm bore pipes complete all as specified and directed. |
| 79 | S &F for PVC (SWR) pipes single soketed, in any length with rubber ring joints, fixed to walls, 75mm bore pipes complete all as specified and directed. |
| 80 | S & F in repairs curtain rails 20m bore harrison rail, aluminium alloy chromium plated with fixing brackets, stops, rollers etc compete all as specified and directed. |
| 81 | Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 82 | Material and labour for RCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in slab supported on walls, beams and column in floors, roof landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. (Note : Reinforcement shall be measured and paid seperately under relevant) |
| 83 | Material and labour form work to soffit of suspended slab such as roof, floor slabs, landing similar work for rough finished surfaces of concrete, flat complete all as specified and directed. |
| 84 | Material and labour form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm but not exc 10cm wide for rough finished surfaces of concrete, flat complete all as specified and directed. |
| 85 | M&L for 20mm thick granite (of any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixure of pigment to match the shade of granite complete all as specified and directed. |
| 86 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 87 | Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed. |
| 88 | Taking down carefully MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 89 | Taking down fan, sealing cable end, dismantling blades and removing fan and keeping it in MES store for safe custody and refix it after repair all compete all as specified and directed. Please Enable Macros to View BoQ information |
| 90 | Taking down fan, sealing cable end, dismantling blades and removing fan and keeping it in MES store for safe custody and refix it after repair all compete all as specified and directed. Please Enable Macros to View BoQ information |