| 1 | Supply, installation,commisioning and testing LT feeder pillar box out door type double door and single shutter front open including locking arrangement system made out of MS sheet of 3.15 mm CRCA sheet of size 0.6x0.6x0.3 mtr and double door,canopy,dust proof, bottom cable entry plate and gland for cable size150/120/95/70/50/25/16/10 sqmm 3.5 core suitable MS angle iron 40x40x5 mm with aluminium busbar size 600Amps system mounted on hygroscopic insulators bus bar including suitable nut, Bolt and Washer(16 Nos) & including powder coated paint with and providing necessary foundation/ plateform of the feeder pillar height 1.5 feet from groundwith PCC 1:2:4 type B2 including provision of for incomong and outgoing cable gland, thimbling for old / new cables as per site requirement and proper finshing as per existing surface complete all as specified and directed Note: Drawing for LT feeder piller box shall be got approved by GE before fabrication. |
| 2 | M&L for painting theLT feeder pillar box outer and inner surface of with two coats of synthetic enamelled paint from spray machine after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after greasing of busbar complete all as specified and directed |
| 3 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr deep for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and not exc 1.5m in depth and getting in hard/dense soil complete all as specified and directed |
| 4 | Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25cm complete all as specified and directed |
| 5 | Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 6 | M & L PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation of poles.LT panel,Feeder piller boxes complete all as specified and directed. |
| 7 | Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. Note:(i) Consolidated / Punned sand shall be considered for purpose of payment (ii) Sand shall be same as specified for plastering work. |
| 8 | Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specified and directed. |
| 9 | Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 50 to120 Sqmm 3.5 core. |
| 10 | Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 150 to240 Sqmm 3.5 core. |
| 11 | S&F in repalement Steel tubing galvanised iron, light grade 40 mm bore for cable protection along the pole, under road/ depth or under drains complete including 30x5mm FI clamps made to shape incl nuts, bolts & washers complete and taking down old unserviceable pipe all as specified all as specified and directed |
| 12 | All as per serial item No: 11 here-in-before but of size 50mm bore. |
| 13 | Double walled corrugated HDPE duct pipe of 63 mm inner dia confirming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 14 | Locating the fault in LT cable of any size for any type of fault like open cable, short between phases/ neutral, grounded cable with help of cable fault locator and pin pointing location with the help of audio signal, exacavation at the fault and opening cable to suitable distance and depth for making a cable joint complete all as speified and as directed. (Note: 1. The joint kit and necessay earth work will be measured and paid separately. 2. Contractor will have to arrange the cable fault locator or other testing equipments/ tools as required and same shall be deemed to be included in the item rate quoted.) |
| 15 | Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed. (Note: 1. Pole to Pole of all line conductor shall be measured as Per RM. 2. Rate including unwinding of old winding wire and rewind with new binding wire after restretching) |
| 16 | M&L for PVC Junction box of size 340mm x 285mmm x 120mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and outgoing cable/wire complete comprising of aluminium bus bar for 3 phases & neutral, insulated with insulators, including colour coding and 01 Nos MCB 06 Amps complete including taking down old unserviceable junction box all as specified and directed. |
| 17 | M&L for renewal of earthing of poles/system with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried vertically in ground not less than 2.25 metres below ground level with top edge of the plate not less than1.5 mtr below ground level, connected to GI strip 32x6mm by means of nuts, bolts and washers and encased in and inclduing 40mm dia GI light grade pipe upto 2.4 mtr height from ground level fixed by MS flat iron clamp 40mmx5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to existing system with alternate layers of charcoal dust, salt packed around plate 150mm thick including watering GI pipe, medium grade 20mm dia, 1.5mtr long fixed to funnel with wire mesh complete with PCC chamber and RCC chamber cover all as per electrical plate No. 3 SSR part I-2009 including excavation and earth work in any type of starta and testing on completion. (Note:- GI strip and GI pipe beyond 7.5M long shall be measured and paid separately) |
| 18 | Dismantling old unsv and Supply, installing, testing & commissioning of LT sheet metal enclosure outdoor type dust & Vermin proof (duly painted with powder coating 6 tank process). Cable lugs are to be used to terminate cables/wires, and necessary connections all as directed by Engineer-in-Charge, self supporting fabricated out of CRCA steel sheet 3.15 mm thick, of size (1000x700x350) with base mounted on angle iron frame (40x40x4 mm) incldg 4 Legs 60 cms long made of angle iron (40x40x4 mm) grouted 30 cms below ground with PCC 1:2:4, cubicle type comprising of following:-(a) Onload Changeover Switch 200 Amps, 4 pole - 01 Nos. (b) Digital Volt meter, AC, single phase 0-500 volt 48x96 mm, 3 1/2 digit, -03 Nos. (c) Digital Amp meter, AC, 0-100 Amps 48x96 mm, 3 1/2 digit incldg CT (100 : 5), -03 Nos. (d) Digital frequency meter, AC, single phase 50 Hz, 48x96 mm, 3 1/2 digit, -01 Nos. (e) Aluminium bus bar 400 amps rating |
| 19 | Dismantling old unsv and Supply, installing, testing & commissioning of 4ways(TPN) LT sheet metal enclosure Busbar chamber outdoor type dust & Vermin proof (duly painted with powder coating process).Aluminium bus bar 100 amps rating with sepreter and coiuor coding 4 way Cable lugs are to be used to terminate cables/wires, and necessary connections wall/poles with clamps and nut bolts all as directed. |
| 20 | Supply and fix in replacement of MCB 4pole isolater TPN 80/100 Amps capacity AC 415 Volts complete all as specified and directed |
| 21 | Supply, laying and testing PVC insulated, screened, PVC bedded, galvanised steel strip or wire electric power cable 1100 volts with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and as directed. |
| 22 | Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 10 Sqmm 4 core laid in trenches or under road complete all as specified and as directed. |
| 23 | S&F in repalement Aluminium bus bar 400 amps rating with lugs and porcoline insulater suitable for t lt panel complete all as directed |
| 24 | S&F in repalement copper bus bar 200 amps rating with lugs and porcoline insulater suitable for t lt panel complete all as directed |
| 25 | S&F in repalement LED type indicator lamps (R |
| 26 | S&F in repalement salector switch with wiring suitable for 500 volt lt panelcomplete all as directed |
| 27 | S&F in repalement Digital frequency meter, AC, single phase 50 Hz, 48x96 mm, 3 1/2 digit with wiring suitable for lt panelcomplete all as directed |
| 28 | S&F in repalement Digital Volt meter, AC, single phase 0-500 volt 48x96 mm, 3 1/2 digit with wiring suitable for 500 volt Lt panelcomplete all as directed |
| 29 | S&F in repalement Digital Amp meter, AC, 0-100 Amps 48x96 mm, 3 1/2 digit incldg CT (100 : 5), with wiring suitable for lt panelcomplete all as directed |
| 30 | Supply & fixing in replacement of Nature switch Panel fixing for street light switch of wall/pole mountable PVC enclosure conforming to IP 65 consisting of Nature switch smart SPD.Isolater,MCB ddrive for loading , and terminal blocks the enclosure comes complete with mounting brackets 16 amp 5 KW, three Phase - contactor rating 16/63 A - 01 No, MCB TPN, 01 No and MCB DP, 240volts 16 Amp 01 No complete all as specified and directed |
| 31 | Supply and fix in replacement of MCCB 4 pole with adjustable type 400 Amps 36 KA capacity AC 415 Volts with connecters ,seprators and nut bolts washers complete all as specified and directed |
| 32 | Supply and fix in replacement of Aluminium lugs size 16,25,35,50 sqmm each size lugs 20 Nos with nut bolts washers etc complete all as specified and directed. |
| 33 | Supply and fix in replacement of Aluminium lugs size 95,120,150,185 sqmm each size lugs 20 Nos with nut bolts washers etc complete all as specified and directed. |
| 34 | Supply and fix in replacement of Aluminium lugs size 240,300,400 sqmm each size lugs 20 Nos with nut bolts washers etc complete all as specified and directed. |
| 35 | Supply & fix in replacement of MCCB 4 Pole with Thermal megnatic release 630 amps capacity AC 415 V,50kA with connecters ,seprators and nut bolts washers complete all as specified and directed. Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |