| 1 | (A) Safe loading & carriage including Loading-unloading & proper stacking of following store materials from ESC Tripula to site of work. |
| 2 | ST Pole 11 Mtr Long |
| 3 | PCC Pole 11 Mtr Long |
| 4 | PCC Pole 8.5 Mtr Long |
| 5 | MS Channel (Dropper) 100x50x2028mm (for fuse set) |
| 6 | MS Top Channel (125x65x2240mm) |
| 7 | 11 KV Disc Insulator T&C type 4500 kg |
| 8 | 11 KV Disc Fitting |
| 9 | MS Channel 125x65x1300mm (T-off) |
| 10 | 11 KV Pin Insulator (Polymeric) |
| 11 | 33 KV Pin Insulator (Polymeric) |
| 12 | 11/0.4 KV Transformer 100 KVA |
| 13 | 11/0.4 KV Transformer 250 KVA |
| 14 | LT ABC (3x95+1x70+1x16) Sq.mm |
| 15 | Stay Set Complete 16X1800 |
| 16 | ACSR Weasel Conductor |
| 17 | ACSR Dog Conductor |
| 18 | LT Distribution Box |
| 19 | 11 KV TPMO |
| 20 | 11 KV Fuse Set |
| 21 | LT PVC Cable Al 3.5x400 Sq.mm |
| 22 | LT PVC Cable 3.5x150/70 Sq.mm |
| 23 | LT PVC Cable 1x400 Sq.mm |
| 24 | MS Earthing Rod 20x2500mm With GI Wire |
| 25 | 11 KV \\"V\\" Type Cross Arm |
| 26 | 33 KV \\"V\\" Type Cross Arm 100X50x6 mm Channel |
| 27 | ERRECTION |
| 28 | Errection of 8.5 Mtr long PCC Pole On D/P including digging of Pits & fitting of accessories. |
| 29 | Errection of 8.5 Mtr long PCC Pole including digging of Pits & fitting of accessories. |
| 30 | Errection of 11 Mtr long PCC Pole On D/P including digging of Pits & fitting of accessories. |
| 31 | Errection of 11 Mtr long ST Pole including digging of Pits & fitting of accessories. |
| 32 | Grouting of Poles as per RESSPO norms with grouting materials as per RESSPO Norms. (0.268 Cu.m.each) |
| 33 | Laying of LT PVC cable of size 1X400 Sq.mm. complete in all respect as per RESSPO norms |
| 34 | Laying of LT PVC cable of size 3.5X400 Sq.mm. complete in all respect as per RESSPO norms |
| 35 | Laying of LT PVC cable of size 3.5X150X/70 Sq.mm. complete in all respect as per RESSPO norms |
| 36 | Earthing of Pole by MS Earthing Rod 20X2500 mm |
| 37 | Mounting Of New 100 KVA T/F on DP as per RESSPO Norms. |
| 38 | Mounting Of New 250 KVA T/F on DP as per RESSPO Norms. |
| 39 | Labour charges for digging of 60 feet deep well type earthing for neutral of Distribution transformer at two different places and welding of G.I. strip including the cost of M.S. pipe 1.5 inch dia 40 feet long and G.I. strip 50X6 mm of suitable length for connecting M.S.pipe to neutral through proper welding or bolt and nut. (NEUTRAL & BODY) All material will be provided by contractor including labour charges and consumables. |
| 40 | Providing and erecting MS/GI fencing around 250 KVA Distribution Transformer plinth complete with angle iron posts, horizontal members, barbed wire/chain link mesh, locking arrangement, welding, painting, and all accessories as per UPPCL specifications and direction of Executive Engineer In-charge. |
| 41 | Providing and constructing RCC plinth of size approximately 2m × 2m × 1.5m for installation of 250 KVA Distribution Transformer complete with excavation, PCC, RCC work, reinforcement, brick masonry, plastering, cable opening, grouting and finishing as per /UPPCL specifications and direction of concerned Executive Engineer In-charge. |
| 42 | Instalation of Stay Set Complete 16X1800 |
| 43 | Fixing of 11 KV \\"V\\" Type X-Arms as per RESSPO Norms |
| 44 | Fixing of 33 KV \\"V\\" Type X-Arms (100X50X6 mm) as per RESSPO Norms |
| 45 | Stringing & sagging of 3ϕ3wire 11 KV LT line by ACSR weasel conductor including all associated works & making clearence of road with joints/jumpers & binding on insulators as required. |
| 46 | Stringing & sagging of 3ϕ3wire 11 KV LT line by Dog weasel conductor including all associated works & making clearence of road with joints/jumpers & binding on insulators as required. |
| 47 | Instalation LT Distribution Box |
| 48 | Instalation of decentalized material as per Respo/uppcl norms |
| 49 | Installation of 11 KV TPMO |
| 50 | Installation of 11 KV Fuse set |
| 51 | TAIL LESS UNIT WITH ALL ACCESSORIES 500A FOR 250 KVA T/F (ALL THE ACCESSORIES AND NECESSARY ARRANGEMENT SHALL BE MADE BY CONTRACTOR) |
| 52 | Instalation of LT Fuse Set Protection Unit with SMC Box |
| 53 | Streinging of LT ABC (3x50+1x35+1x16) sq mm Cable as per RESSPO Norms |
| 54 | Insttalation of LT Incoming Panel with Metering Equipment & Fixing Arrangement |
| 55 | PROVIDED BY CONTRACTOR |
| 56 | Clamps for LT T-off with bolts & Nuts |
| 57 | Stone pad 300x300x75mm |
| 58 | LT Piercing Connector 95 Sq.mm |
| 59 | Connecting Lead 1x16 Sq.mm |
| 60 | Holding clamps for TPMO/Fuse set etc. |
| 61 | LT Pole Clamp with nuts & bolts |
| 62 | Suspension Clamp with I hook |
| 63 | danger Board, Barbed Wire including Jumper |
| 64 | F-Bracket with N&B |
| 65 | LT Incoming Panel with Metering Equipment & Fixing Arrangement |
| 66 | Copper L-piece 50x225x10 mm |
| 67 | Copper L-piece 62x225x12 mm |
| 68 | 4 Core LT MCB with Box |
| 69 | Danger Board, Barbed Wire including Jumper |
| 70 | Red Oxide Paint |
| 71 | Aluminium Paint |
| 72 | LT Fuse Set Protection Unit with SMC Box |
| 73 | MS Angle 75x75x6x2028mm with Clamp & Bolt Nut (TF Base) |
| 74 | Earth Wire Clamps for PCC Pole |
| 75 | Aluminium Lug Off Size |
| 76 | Holding Clamps Various Type |
| 77 | Clamps for 11 kv v type X-arm With Nut bolt |
| 78 | E-bracket For 33 Kv |
| 79 | danger Plate with clamp nut and bolt |
| 80 | GI Barbed Wire |
| 81 | Nut Bolt And Washer All Sizes Please Enable Macros to View BoQ information |