Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PHED Revised BSR 2023 -1.1 - Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 2 | PHED Revised BSR 2023 -1.1.2 - 100 mm |
| 3 | PHED Revised BSR 2023 -1.1.3 - 150 mm |
| 4 | PHED Revised BSR 2023 -1.1.4 - 200 mm |
| 5 | PHED Revised BSR 2023 -1.1.5 - 250 mm |
| 6 | PHED Revised BSR 2023 -1.1.6 - 300 mm |
| 7 | PHED Revised BSR 2023 -1.6 - Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 8 | PHED Revised BSR 2023 -1.6.1 - Outer dia of pipe 219.1 mm and thickness |
| 9 | PHED Revised BSR 2023 -1.6.1.4 - 4.5 mm |
| 10 | PHED Revised BSR 2023 -1.6.2 - Outer dia of pipe 273 mm and thickness |
| 11 | PHED Revised BSR 2023 -1.6.2.4 - 6.3 mm |
| 12 | PHED Revised BSR 2023 -1.7 - Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethylene including preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge.Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface. |
| 13 | PHED Revised BSR 2023 -1.14 - Providing and making inner cement mortar lining to M.S. Pipes with mechanical devices in cement mortar 1:1 proportion , including cost of all materials, labour, special sand required, machinery, power generation, all equipments, including carrying out \\"C\\" value performance test of pipeline, including field joints at site complete as per technical specification and direction of Engineer in In charge. |
| 14 | PHED Revised BSR 2023 -1.14.1 - 9 mm thick for pipes up to 700 mm dia |
| 15 | PHED Revised BSR 2023 -1.15 - Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 16 | PHED Revised BSR 2023 -1.15.1 - MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 17 | PHED Revised BSR 2023 -2.20 - Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 18 | PHED Revised BSR 2023 -2.20.3 - 25.0 Sq.mm, 3.5 core |
| 19 | PHED Revised BSR 2023 -2.20.4 - 35.0 Sq.mm, 3.5 core |
| 20 | PHED Revised BSR 2023 -2.21 - Plate Earthling as per IS:3043 with copper Earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. Below the ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 21 | PHED Revised BSR 2023 -3.4 - Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - |
| 22 | PHED Revised BSR 2023 - - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 23 | PHED Revised BSR 2023 - - h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 24 | PHED Revised BSR 2023 -3.4.3 - Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3. |
| 25 | PHED Revised BSR 2023 -3.4.3.1 - 500 KL capacity CWR At Plot 624 RIICO SIA |
| 26 | PHED Revised BSR 2023 -3.7 - Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 27 | PHED Revised BSR 2023 -3.7.1 - 100 mm |
| 28 | PHED Revised BSR 2023 -3.7.4 - 250 mm |
| 29 | PHED Revised BSR 2023 -3.7.5 - 300 mm |
| 30 | PHED Revised BSR 2023 -4.1 - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 31 | PHED Revised BSR 2023 -4.2 - Add extra for trenches for every additional lift over item no 4.1 |
| 32 | PHED Revised BSR 2023 -4.2.1 - Above 1.5 mtr and up to 3.0 mtr. |
| 33 | PHED Revised BSR 2023 -4.2.2 - Above 3.0 mtr and up to 4.5 mtr. |
| 34 | PHED Revised BSR 2023 -4.5 - Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 35 | PHED Revised BSR 2023 -4.6 - Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 36 | PHED Revised BSR 2023 -4.6.1 - Bituminous courses |
| 37 | PHED Revised BSR 2023 -4.6.2 - Granular courses |
| 38 | PHED Revised BSR 2023 -4.7 - Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 39 | PHED Revised BSR 2023 -4.8 - Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 40 | PHED Revised BSR 2023 -4.8.2 - Plain cement concrete pavement of M-30 Grade |
| 41 | PHED Revised BSR 2023 -4.11 - Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. |
| 42 | PHED Revised BSR 2023 -4.11.2 - 400 mm Dia 8 mm thick casing pipe . |
| 43 | PHED Revised BSR 2023 -4.11.3 - 500 mm Dia 8 mm thick casing pipe . |
| 44 | PHED Revised BSR 2023 -5.6 - Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 45 | PHED Revised BSR 2023 -5.6.2 - 1.5 KW (2.0 HP) |
| 46 | PHED Revised BSR 2023 -5.7 - Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 47 | PHED Revised BSR 2023 -5.7.22 - Discharge 51 to 60 LPS and head 20 to 30 M |
| 48 | PHED Revised BSR 2023 -6.8 - Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 49 | PHED Revised BSR 2023 -6.8.1 - Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 50 | PHED Revised BSR 2023 -6.8.1.2 - 100 mm dia |
| 51 | PHED Revised BSR 2023 -6.8.1.4 - 150 mm dia |
| 52 | PHED Revised BSR 2023 -6.8.1.5 - 200 mm dia |
| 53 | PHED Revised BSR 2023 -6.8.1.6 - 250 mm dia |
| 54 | PHED Revised BSR 2023 -6.8.1.7 - 300 mm dia |
| 55 | PHED Revised BSR 2023 -6.8.3 - Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 56 | PHED Revised BSR 2023 -6.8.3.5 - 200 mm dia |
| 57 | PHED Revised BSR 2023 -6.9 - Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 58 | PHED Revised BSR 2023 -6.9.1 - Class PN 1.6, Manually Operated with Gear |
| 59 | PHED Revised BSR 2023 -6.9.1.4 - 250 mm dia |
| 60 | PHED Revised BSR 2023 -6.9.1.5 - 300 mm dia |
| 61 | PHED Revised BSR 2023 -6.9.3 - Class PN 1.6, Motorised Operated |
| 62 | PHED Revised BSR 2023 -6.9.3.2 - 250 mm dia |
| 63 | PHED Revised BSR 2023 -6.9.3.3 - 300 mm dia |
| 64 | PHED Revised BSR 2023 -6.12 - Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) , Insertion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 65 | PHED Revised BSR 2023 -6.12.1 - Class PN 1.6 |
| 66 | PHED Revised BSR 2023 -6.12.1.5 - 200 mm dia |
| 67 | PHED Revised BSR 2023 -6.13 - Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve class PN 1.6 of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (NonToxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 68 | PHED Revised BSR 2023 -6.13.1 - Class PN 1.6 |
| 69 | PHED Revised BSR 2023 -6.13.1.1 - 40 mm dia |
| 70 | PHED Revised BSR 2023 -6.13.1.2 - 50 mm dia |
| 71 | PHED Revised BSR 2023 -6.16 - Providing, lowering, aligning and fixing in position DI D/F Diaphragm type Pressure Reducing / Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body & Bonnet - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or ASTM A 536, Diaphragm and Resilient seal disc - Flexible, non-wicking nylon fabric reinforced synthetic elastomer -Buna-N / EPDM (FDA / WRAS approved), Body Seat Ring - Cast stainless steel ASTM- A 351 GR. CF8M / AISI- 316, raised, replaceable inline & onsite Stem - Stainless Steel, AISI-316/410, raised, replaceable inline & onsite Spring & Bearing bush- Stainless Steel, AISI-316 ,Disc guide, disc retainer & diaphragm washer - Stainless Steel, AISI-304/ 316/Bronze ,Seal- EPDM/ NBR ,Pilot Body- Stainless Steel, AISI-304/ CF8 or Brass Tubing - Stainless Steel, AISI-304 / Copper ,Solenoid Valve- Stainless Steel, AISI-316 ,Throttling plug - Stainless Steel, AISI-304, Nut- Bolts - SS Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2. insertion rubber of black EPDM 6mm thick Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 72 | PHED Revised BSR 2023 -6.16.2 - Diaphragm Type Flow Control Valve With Electrical Actuator suitable for SCADA (PN 1.6 ) |
| 73 | PHED Revised BSR 2023 -6.16.2.2 - 100 mm dia |
| 74 | PHED Revised BSR 2023 -6.16.2.4 - 150 mm dia |
| 75 | PHED Revised BSR 2023 -6.16.2.6 - 250 mm dia |
| 76 | PHED Revised BSR 2023 -6.16.2.7 - 300 mm dia |
| 77 | PHED Revised BSR 2023 -6.17 - Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 |
| 78 | PHED Revised BSR 2023 -6.17.2 - 100 mm dia. |
| 79 | PHED Revised BSR 2023 -6.17.4 - 150 mm dia. |
| 80 | PHED Revised BSR 2023 -6.17.5 - 200 mm dia. |
| 81 | PHED Revised BSR 2023 -6.17.6 - 250 mm dia. |
| 82 | PHED Revised BSR 2023 -6.17.7 - 300 mm dia. |
| 83 | PHED Revised BSR 2023 -6.18 - Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. |
| 84 | PHED Revised BSR 2023 -6.18.2 - 100 mm dia. |
| 85 | PHED Revised BSR 2023 -6.18.6 - 250 mm dia. |
| 86 | PHED Revised BSR 2023 -6.18.7 - 300 mm dia. |
| 87 | PHED Revised BSR 2023 -7.1 - SITC DOL Starter type LT Panel of following rating, all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. complete as per Technical Specifications and as per direction of Engineer-In-Charge. |
| 88 | PHED Revised BSR 2023 -7.1.1 - DOL STARTER 2.2 KW (3 HP)- : For 2 motors (1 W+ 1S) I/C - MCB 25A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 30/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 16A ,TP, 10 KA, C Curve (2), Power Cont 9A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (4-6A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2) |
| 89 | PHED Revised BSR 2023 -7.2 - SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. |
| 90 | PHED Revised BSR 2023 -7.2.6 - STAR DELTA STARTER 22.0 KW (30.0 HP) - : For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2) |
| 91 | PHED Revised BSR 2023 -8.2 - Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 92 | PHED Revised BSR 2023 -8.3 - Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. |
| 93 | PHED Revised BSR 2023 -8.4 - Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoor and outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx. |
| 94 | PHED Revised BSR 2023 -8.4.2 - Type II ( 111.34 Sqm) at Plot 624 RIICO SIA |
| 95 | PHED Revised BSR 2023 -9.1 - Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 96 | PHED Revised BSR 2023 -9.1.1. - For Class-AA loading |
| 97 | PHED Revised BSR 2023 -9.1.1.1 - Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-up to 100 mm |
| 98 | PHED Revised BSR 2023 -9.1.1.2 - Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm |
| 99 | PHED Revised BSR 2023 -9.1.1.3 - Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm |
| 100 | PHED Revised BSR 2023 -9.1.3 - For in-campus Valve Chambers |
| 101 | PHED Revised BSR 2023 -9.1.3.1 - Sluice valve chamber of size1.13m x0.85m x1.225mfor pipe size-upto100mm |
| 102 | PHED Revised BSR 2023 -9.1.3.3 - Sluice valve chamber of size1.26m x1.185m x1.76mfor pipe size-from 200-to-300mm |
| 103 | PHED Revised BSR 2023 -9.2 - Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 104 | PHED Revised BSR 2023 -9.2.1 - For Class-AA loading |
| 105 | PHED Revised BSR 2023 -9.2.1.1 - Air valve chamber of size0.9m x1m x1.695mfor air valve size-from 50 mm-to-80mm |
| 106 | PHED Revised BSR 2023 -9.3 - Construction of RCC Scour valve chamber wet type for different type of valves including earthwork excavation, 100mm PCC M15 as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as per direction of Engineer-in-Charge. |
| 107 | PHED Revised BSR 2023 -9.3.1 - For Class-AA loading |
| 108 | PHED Revised BSR 2023 -9.3.1.1 - Scour valve chamber of size1.13m x0.85m x1.985mfor connecting pipe size-upto100mm |
| 109 | PHED Revised BSR 2023 -10.1 - Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. |
| 110 | PHED Revised BSR 2023 -10.1.2 - Solar panels more than 10 KW and up to 50 KW at a single location. |
| 111 | PHED Revised BSR 2023 -11.1 - SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. (For Pump house outlet, and CWR inlet) |
| 112 | PHED Revised BSR 2023 -11.1.3 - EFM100 mm (Inlet of CWR at PU) |
| 113 | PHED Revised BSR 2023 -11.1.6 - EFM 200 mm (Delivery Header of Pump House and inlet of CWR at JECRC) |
| 114 | PHED Revised BSR 2023 -11.1.7 - EFM 250 mm (Inlet of CWR Plot No. 624 and Inlet of CWR at MGUMST) |
| 115 | PHED Revised BSR 2023 -11.1.8 - EFM 300 mm (Inlet of CWR RIICO pump house) |
| 116 | PHED Revised BSR 2023 -11.4 - SITC of Ultrasonic Level Transmitter suitable for measuring water level in reservoir, Normal Powered 24VDC, Type of Transmitter: Two Wire ( 4-20 mA), Cable Entry:1/2\\" NPT (F), Sensor Material: PP, slip-on Flange: 2 ½” Flange, Material of Construction for Slip-on flange: PP, output 4~20mA, HART compatible, accuracy +/_ 0.2 % as per detailed Technical specification, scope of work and direction of Engineer in charge. |
| 117 | PHED Revised BSR 2023 -11.4.1 - Measuring range 0.0 to 6.0 mtr (For 1 no. Proposed CWR and 4 nos. existing CWRs) |
| 118 | O&M BSR 2018 Japur/ 1.3 - Work of inter Connection in CI/DI/MS pipe line including dismentalling of BT road/ CC road/ excavation of soil, cutting of existing pipeline, jointing of Tee (complete) and other specials excluding sluice valve, dewatering, transportation from JE store and providing adequate safety of site & testing for water proof inter connection using his own T&P, labour & dewatering pump etc. required to complete the job. (Material such as Tee/ Tee Clamp/ rubber sheet/ CID joints required for Inter connection shall be provided by the department free of cost). In Bitumunous Road. 300mm to 400mm |
| 119 | PWD BSR -2022 1.8 - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 120 | PWD BSR 2022 B-3/3.1.1 - Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excludingthe cost of centering and shuttering - All work up to plinthlevel. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). |
| 121 | PWD BSR 2022 B-3/3.1.4 - Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excludingthe cost of centering and shuttering - All work up to plinthlevel. M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate40mm nominal size). |
| 122 | PWD BSR -2022 3.1.6 - Providing and laying in position cement concrete 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth leve |
| 123 | PWD BSR -2022 4.4 - Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boardsM20 grade Nominal Mix / Design Mix |
| 124 | PWD BSR 2022 B-4/4.10.1 - Centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props andremoval of formwork for upto floor five level for :Walls (anythickness)including attached pilasters,buttresses plinth and string course. |
| 125 | PWD BSR -2022 4.10.2 - Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 126 | PWD BSR -2022 4.13.3 - Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 127 | - Thermomechanical Twisted Bars |
| 128 | PWD BSR -2022 5.2.2 - Brick work with bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 129 | PWD BSR -2022 6.1.6 - Random rubble masonry with hard stone in foundation and plinth |
| 130 | PWD BSR -2022 9.17 - Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 131 | PWD BSR -2022 9.17.1 - Add extra for double leaf shutters. |
| 132 | PWD BSR -2022 9.19.4 - Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 133 | PWD BSR -2022 9.26 - Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 134 | PWD BSR -2022 9.27 - Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 135 | PWD BSR 2022 9.32 - 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. |
| 136 | PWD BSR -2022 11.18.1 - Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 901 to 2000 Sq.Cm : |
| 137 | PWD BSR -2022 11.19.1 - Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001 Sqcm |
| 138 | PWD BSR -2022 11.26 - Random rubble dry stone Kharanja (soling) under floor |
| 139 | PWD BSR -2022 12.2.2 - Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20 mm th |
| 140 | PWD BSR -2022 12.3.2 - Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20 mm th. |
| 141 | PWD BSR -2022 12.38 - Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturer's specification. Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 142 | - Two or more coats on new work. (Internal Painting |
| 143 | PWD BSR -2022 12.41 - Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: |
| 144 | 12.41.1 - New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 145 | PWD BSR -2022 15.25 - Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry : |
| 146 | 15.25.2 - Size 125 x 100mm |
| 147 | PWD BSR 2022 H-1.2 - Supply of Chemical Fertilizers at store in bags weighing not less than 50 kg each including loading unloading & transportation |
| 148 | 1.2.1 - Urea |
| 149 | 1.2.2 - DAP |
| 150 | PWD BSR 2022 H-1.3 - Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. |
| 151 | 1.3.1 - Good soil of earth |
| 152 | PWD BSR 2022 H-1.4 - Supply of insecticides & Pesticides at store in dust/liquid form complete. |
| 153 | 1.4.1 - Methyl Prathion 2% |
| 154 | PWD BSR 2022 H-1.11 - Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete |
| 155 | 1.11.1 - Different flowering plants 900mm to1500mm |
| 156 | 1.11.2 - Different varieties of shrubs 600mm to 900 mm |
| 157 | 1.11.3 - Different varieties of climbers 900mm to 1500 mm |
| 158 | PWD BSR 2022 H-1.12 - Supply of different varieties of bougainvillea in ply bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete |
| 159 | 1.12.1 - Local variety of bougainvillea 600mm to 900mm |
| 160 | 1.12.2 - Different varieties of bougainvillea 600mm to 900mm |
| 161 | PWD BSR 2022 H-1.13 - Supply of different varieties of rose plants in poly bag/ earthen pot according to height growth and age of the plant at site including loading unloading and transportation etc. complete |
| 162 | 1.13.1 - Desi rose / root stock plant 1 to 1.5 feet |
| 163 | 1.13.2 - Ganganagari rose plant in poly beg 1 to 2 feet |
| 164 | 1.13.3 - Different varieties of grafted rose plants in poly bag 1 to 1.5 feet |
| 165 | 1.13.4 - Different varieties of grafted rose plants in poly pot/earthen pot 1 to 1.5 feet |
| 166 | PWD BSR 2022 H-3.1 - Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost |
| 167 | 3.1.1 - In rows 15 cm apart in either direction |
| 168 | PWD BSR 2022 H-3.4 - Preparation of different sized bed as directed |
| 169 | PWD BSR 2022 H-5.2 - Supply & Panting of ornamental plants ( Kachnar, Amaltas, Gulmohar, Arjun, Kala, Siris, Jacranda etc. or other specified) along road side including the following activities :- Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. Supply of plant at site of two years of age & height more than 1.50 Mtr. Supply of dry manure( Farm yard manure organic). Supply of Insecticides & Pesticides at store in dust/liquid form complete. Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 1.5 liter per plant after planting. |
| 170 | RUIDP SOR 2023 - 9.4 - Providing and laying un-reinforced, dowel jointed, plain cement concrete mix in pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted andfinished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery,lighting, guarding and maintenance of diversion. |
| 171 | 9.4.3 - PCC M-30 |
| 172 | RUIDP 2023-9.10.2 - Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge.The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. 80mm thick |
| 173 | RUIDP SOR 2023 - 19.57 - Providing, lowering, laying, aligning, fixing in position and jointing CI D- joint class-10 as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 174 | RUIDP SOR 2023 - 19.57.7 - 300 mm dia |
| 175 | RUIDP SOR 2023 - 21.1 - Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : |
| 176 | 21.1.5 - 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 177 | RUIDP SOR 2023 - 22.1 - Centring and shuttering with plywood or steel sheet upto two stories( each story of height upto 3.5 metre from floor level) including strutting, propping etc. and removal of form for : |
| 178 | 22.1.1 - Foundations, footings, bases of columns, etc. for mass concrete. |
| 179 | RUIDP SOR 2023 - 23.3 - Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar |
| 180 | 23.3.3 - M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix) |
| 181 | RUIDP SOR 2023 - 23.19 - Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. |
| 182 | 23.19.6 - Thermo-Mechanically Treated bars. |
| 183 | RUIDP SOR 2023 - 32.1 - Cement plastering including T&P, scaffolding, material and completelabour, including cost of water, curing, racking of joints etc. with 12mm cement plaster of mix : including Providing /mixing of syntheticfibers compulsorily complying with IS 16481:2022 of 06 mm/12 mmlength to be mixed @ 0.25% by weight of Cement i.e. 125 gms per50 kg Cement up to 900 gms per cum of Concrete/ mortar |
| 184 | 32.1.2 - 1:6 (1 cement : 6 fine/ coarse sand) |
| 185 | RUIDP SOR 2023 - 42.35 - P &F in position frame made out of M.S. angle (riveted or welded) finished with two coat of red oxide and enamel paint including cutting, welding, holes etc. of following sizes as required. |
| 186 | 41.35.1 - 40mm X 40mm X 5mm |
| 187 | RUIDP SOR 2023 - 42.33 - P/Laying P.V.C/XLPE insulated & P.V.C sheathed cable of 1.1 KV grade with Copper conductor of IS: 1554 P-I/IS: 7098 P-I in ground as per IS: 1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 188 | 42.33.1 - 2.5 sqmm. Armored 4 core |
| 189 | 42.33.2 - 1.5 Sq.mm Armoured 6 Core |
| 190 | RUIDP SOR 2023 - 43.7 - Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \\"NPT (M) / Accuracy: 0.15% Protection: IP67 (For pump house) |
| 191 | RUIDP SOR 2023 - 47.2 - Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: |
| 192 | 47.2 - DI 46 No. DO 42 No. AI 10 No. AO 4 No. MCB 16A DP 2 No. MCB 6A DP 6 No. SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC TypeMicroprocessor Based, Window Size 75*42mm,110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No. Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No. Panel Light with Door Switch, 7W 1 No. Control Indication Lamp for 24VDC, 220VAC 3 No. Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls,name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No. HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot (At proposed Pump House) |
| 193 | RUIDP SOR 2023 - 47.12 - Compact RTU complete with DI, DO, AI and modbus communication ports and power supply. // Compact RTU for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and Communcation protocols, on-board I/O (8 DI, 4 DQ, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem and having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. (At 3 nos. existing CWRs) |
| 194 | RUIDP SOR 2023 - 48.3.2 - 8ch Network Video Recorder- Connect Up to 8 IP Cameras, DualOS, Up to 8 Megapixels Resolution, HDMI and VGA independentoutputs provided, HDMI Video output at up to 4K (3840 × 2160)resolution , VGA upto 1920 × 1080, Support H.265, MJPEG,Incoming Bandwidth 80 Mbps, 4 SATA Hard Disks, ANRTechnology, 4 SATA interfaces for 4 HDDs and capacity of eachHDD upto 6TB, 3× USB at least 1 × USB with 3.0, Alarm I/O 16/4,RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernetinterface, Multiple network monitoring: Web viewer, CE, FCC, BIScertified. |
| 195 | RUIDP SOR 2023 - 48.3.6 - Supply Installation, Testing & Commissioning of Intel i7 4th Generation processor 3Ghz or latest, 4GB RAM with 2TB hard disk, DVD-RW/keyboard/optical mouse/LAN card/24” LED monitor. Minimum 6 USB ports. With pre-loaded licensed Windows 10 or latest software PC (At propopsed Pump House) |
| 196 | RUIDP SOR 2023 - 48.3.18 - Supply, Installation, Testing & Commissioning of 5 MP IR FixedBullet Network Camera -1/2.7 inch Progressive Scan CMOS, 2592 ×1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IRon, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), supportH.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction,BLC, HLC, Three individually configurable stream, 12 VDC & PoE,IR range: 40m, Support on-board storage including SD Card up to256 GB , IP67, Alarm 1 inputs, 1 outputs, Audio 1 inputs, 1 outputs,Edge Analytics- Line crossing detection, Intrusion detection, Motiondetection, Region entrance detection, Region exiting detection,Scene change detection, Face capture, Video tampering, audioexception detection, False alarm reduction through human andvehicle target classification based on deep learning CE, FCC, BIScertified |
| 197 | RUIDP SOR 2023 - 54.3 - Providing & Fixing of Powder coated CRCA sheet on existing angleiron frame by means of nuts and bolts and making holes , etc. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR . |
| 198 | 54.3.3 - 2.0 mm thick |
| 199 | RUIDP SOR 2023 - 57.1 - SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 200 | - [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 201 | - (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 202 | 57.1 - (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 203 | RUIDP SOR 2023 - 57.2 - Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 204 | 57.2.1 - Electrolytic grade Aluminium bus bar 6010 grade |
| 205 | 57.2.2 - Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade |
| 206 | RUIDP SOR 2023 - 57.3 - Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, makingconnection by PVC insulated copper conductor with PVC sleeves /channel etc. Meter shall give true RMS measurments, acc. CI 1.0 orbetter , with field programmable primary & sec. values PT(VT)primary upto 2000 KV. Field-programmable high and low thresholdvalues, meter shall compliance of IS 13875 & IEC 61236. asrequired. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 207 | E080610 - Digital type Confirming to IEC 62053-21 |
| 208 | 57.3.3 - Three phase Ammeter with Inbuilt Selector Switch |
| 209 | 57.3.4 - Three phase Voltmeter with Inbuilt Selector Switch |
| 210 | 57.3.10 - Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 |
| 211 | RUIDP SOR 2023 - 57.4 - Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 27051992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 212 | 57.4.1.3 - C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 213 | 57.4.1.4 - C T Class 1, Ratio 1600/5 to 2000/5, Burden 15 VA |
| 214 | RUIDP SOR 2023 - 57.5.1 - Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Voltage Between Phases with OFF ( 4 Position ) |
| 215 | RUIDP SOR 2023 - 57.6 - Providing & Fixing of ISO certified company made CT linkedselector switch of 10 A for Ampere meter (4 position ) using highgrade engineering material to international standards with camassembly insulation of glass filled polyamide with high trackingindex. For reliable and stable electrical and mechanical endurancedouble butt contacts with silver bi-metal on copper should provided .contact assembly is of operating temp range -25 degree C to 55degree C, frequency upto 10 KHz. switch life under std. op.conditions shall be mechanically minimum 50000 operations @300cycles/ hour and electrically 10,000 operations at 100% rated dutyfor 100 cycles/ hour , including making connection etc. as required .All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR . |
| 216 | RUIDP SOR 2023 - 57.11 - Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 217 | 57.11.1 - Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 218 | RUIDP SOR 2023 - 57.13 - Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 219 | 57.13.1 - 6 to 8 stage |
| 220 | RUIDP SOR 2023 - 58.3 - SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C and inst. protection setting , True RMS sensing. as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable,common fault LED indication, Thermal memory, release trip shall confirm to EMC/ EMI compatability, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree andwithout derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 221 | 58.3.3 - 4 pole MCCB With Thermal Magnetic release |
| 222 | 58.3.3.3 - 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 223 | RUIDP SOR 2023 - 58.4 - Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 224 | 58.4.1 - Shunt Trip Release |
| 225 | 58.4.2 - Under Voltage Release |
| 226 | 58.4.3 - Extended Rotary Handle |
| 227 | 58.4.5 - Mechanical Interlocking kit |
| 228 | RUIDP SOR 2023 - 60.3 - Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed UnarmouredCoppercableconfirmingtoIS:1554P-I/IS:7098P-Iof1.1KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheathconfirming to IS:5831 in existing RCC / Hume / Stoneware / PVCpipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own inhouse NABL accrediated Laboratory for testing procedure as perIS:10810 For additional technical parameters of product / work referAnnexure 'A' attached with this BSR |
| 229 | 60.3.4 - 6.0 Sq. mm |
| 230 | 60.3.4.1 - 2 core |
| 231 | RUIDP SOR 2023 - 61.5 - Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 232 | 61.5.4 - 300mm x 50mm x 1.6mm |
| 233 | RUIDP SOR 2023 - 61.6 - Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 234 | 61.6.4 - 375mm x 50mm x 1.6mm |
| 235 | RUIDP SOR 2023 - 62.1 - Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessaryconnection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % &as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 236 | 62.1.1 - 3 core 95.0 Sq.mm |
| 237 | RUIDP SOR 2023 - 62.7 - Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 238 | 62.7.3 - 11 KV End Termination Kit Indoor type |
| 239 | 62.7.3.2 - 3 core 50/70/95 Sq.mm |
| 240 | RUIDP SOR 2023 - 63.6 - Supply & Laying following size earth wire in horizontal or vertical runin ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. asrequired. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . |
| 241 | 63.6.9 - 10 SWG G.I. ( Hot Dipped ) Wire |
| 242 | RUIDP SOR 2023 - 67.1 - Supply and erection of Galvanized Iron pole with galvanizing donein single dipping (Average coating thickness Minimum 65 Microns)continuously tapered poles having Octagonal / Circular crosssectionsdesignedtowithstandthemaximumwindspeedasperIS875,The pole shaft shall be made from sheet steel (HT SteelConforming to grade S355JO) and confirming to BSEN 10025 andshall be continuously tapered with single longitudinal welding. Thereshall not be any circumferential welding. The welding of pole shaftshall be done by Submerged Arc Welding (SAW) process. poleshafts shall be provided with the rigid flange plate of suitablethickness (Fe 410 conforming to IS 226 / IS 2062) with provision forfixing 4 no. foundation bolts, This base plate shall be fillet welded tothe pole shaft at two locations i.e. from inside and outside.Theoctagonal Poles shall have lockable door of approximate 500 mmlength at the elevation of 500 mm from the Base plate with bakelitesheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos)inside the pole at door opening for cable connection of followinglength and dimension as per table P-01 with base plate andfoundation bolt on the Existing cement concrete foundation.All asper pre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 243 | 67.1.1 - Poles with Octagonal Cross Section |
| 244 | 67.1.1.6 - 8 Mtr. |
| 245 | RUIDP SOR 2023 - 67.2 - Supply and Fixing of Pole OEM fabricated hot dipped galvanisedM.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25mm) over the existing poles. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR . |
| 246 | 67.2.1 - Single arm overhang |
| 247 | RUIDP SOR 2023 - 67.8.2 - Providing and Laying RCC Foundation for Octagonal / ConicalStreet Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR . A) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. G) Providing and Laying Reinforce cement Concrete of M-25 gradein Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 248 | RUIDP SOR 2023 - 67.11 - Providing & Fixing of IK08 IP-66 protected high power LED floodlight system with single piece Pressure diecast aluminium housing,toughened glass diffuser with suitable lenses on LED to achievevarious beam angles, of high power LED of 3 to 5 watt each .Integrated potted driver as a unique BIS R number having efficiencymore than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LEDdriver Input Voltage AC 120 to 270 V AC with High voltage Cutoff@>=300 V AC and Auto resetting Safety .Power Factor >0.95 ,THD(I) <10% , driver current <=750mA. driver should be Phase tophase protection of 440 V for 4 Hrs. Electrical Connector , SurgeProtection Min >=4KV internal and 10KV external but inside drivercompartment, System life of 50000 Burning hours with 70% of InitialLumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixtureshall be IS 10322 Complianced.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 249 | 67.11.1 - High Power LED Flood Light Minimum lumen output 3700 lm |
| 250 | RUIDP SOR 2023 - 67.16 - Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mmfabricated of 1.6mm MS sheet with hinged cover, dust and verminproof, rubber gasket, locking arrangement, duly holded with 2 nospole clamps of 20 mm x 3 mm flat with nut and bolts, complete withanticorrosive treatment, finished with two coat of approved enamelpaint. The box shall be provided with 2 / 4 nos copper bus bar 125 x20 x 3 mm with brass screws suitable supports,earth terminal, interconnection, knock outs for 20 / 25 mm cable gland, 1 no. 6 AmpMCB complete in all respect. All as per pre approved by Engineerin-charge. For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR . |
| 251 | RUIDP SOR 2023 - 67.18 - Providing & Fixing of Street light bracket made out from followingsize of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P -1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc.as required. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . |
| 252 | 67.18.1 - 20 mm Dia. |
| 253 | RUIDP SOR 2023 - 69.1 - Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copperwire insulated with PVC, UTP (Unshielded Twisted Pair), Category6, Class E, 100 Ohm Impedance, Indoor Cable as per latestammendments of ANSI/TIA/EIA-568 , The copper conductors shouldbe balanced twisted in pairs, seperated by a cross-member flutedpair divider & protected by PVC Jacket. Certified performance in a4-connector configuration upto 100 Mtrs channel requirements &transmission frequencies up to 250 Mhz. in existing MS/PVCConduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at bothends for identification with necessary tools for punching, stripping,crimping and testing etc as required complete in all respect. All asper pre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 254 | RUIDP SOR 2023 - 72.2 - S I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved asper IS 2026- 1977 & lossesas defined as per IS 1180 part I 2014. including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated/ CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspectioncharges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR . |
| 255 | 72.2.1 - 63 KVA |
| 256 | RUIDP SOR 2023 - 72.4 - Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ |
| 257 | RUIDP SOR 2023 - 72.5 - SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (NonFerrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 258 | 72.5.1 - Non Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch |
| 259 | RUIDP SOR 2023 - 72.11 - Supply , Installation, Testing and Comissioning of following capacity End Feed Unit Confirming to ANSI C37.23 standard & IS 8623 P-II suitable for Sandwich typy for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB/ACB (but withoutMCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 260 | 72.11.1 - For 200 Amp. (Without MCCB) |
| 261 | RUIDP SOR 2023 - 72.28 - Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including levelling, Dressing etc. as Required. |
| 262 | RUIDP SOR 2023 - 72.20 - Supply & fabrication steel structure with MS channel / angle / joist /ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , onecoat of primer & two coat of enamel paint etc. as required completein all respect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . |
| 263 | Operation and Maintenance of Transmission main, Rising pipe line, Clear Water Reservoir, Pump House, Pumping Machinary, Other Miscellaneous Civil Works, Transformer, SCADA & Instrumentation work etc for a period of Five year ( 5 % incremental increase per year) |
| 264 | 1st Year |
| 265 | 2nd year (1st Year x 1.05) |
| 266 | 3rd year (2nd Year x 1.05) |
| 267 | 4th year (3rd Year x 1.05) |
| 268 | 5th year (4th Year x 1.05) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail