| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with PVC switch board and fancy type switch with cover plate including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point with fancy type 5/6 amps switch and socket with cover plate including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 15/16 amps plug point with fancy type 15/16 amps switch and socket with cover plate including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on PVC switch board, earthing the 3rd pin etc. as required;- |
| 7 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 8 | Short Point :- |
| 9 | Medium Point :- |
| 10 | Long Point :- |
| 11 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 12 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 13 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 14 | 2 X 1.5 sq mm |
| 15 | 2 X 2.5 sq mm |
| 16 | 2 X 4 sq mm |
| 17 | 2 X 6 sq mm |
| 18 | 4 X 4 sq mm |
| 19 | 4 X 6 sq mm |
| 20 | 4 X 10 sq mm |
| 21 | 4 X 16 sq mm |
| 22 | 4 X 25 sq mm |
| 23 | 4 X 35 sq mm |
| 24 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 25 | 1 X 1.5 sq mm |
| 26 | 1 X 2.5 sq mm |
| 27 | 1 X 4 sq mm |
| 28 | 1 X 6 sq mm |
| 29 | 1 X 10 sq mm |
| 30 | 1 X 16 sq mm |
| 31 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
| 32 | 20mm x 12mm |
| 33 | 25mm x 12mm |
| 34 | 32mm x 12mm |
| 35 | 38mm x 16mm |
| 36 | 50mm x 16mm |
| 37 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 38 | 19/20 mm dia |
| 39 | 25 mm dia |
| 40 | 32 mm dia |
| 41 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
| 42 | 19/20 mm dia |
| 43 | 25 mm dia |
| 44 | 32 mm dia |
| 45 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 46 | 5/6 amps piano type switch |
| 47 | 5/6 amps piano type 2-way switch |
| 48 | 3 pin 5/6 amps piano type socket |
| 49 | 3/6 pin 16/20 amps piano type socket |
| 50 | Electronic 4 step mini fan regulator |
| 51 | Pandent holder |
| 52 | Angle/batten holder |
| 53 | Ceiling rose |
| 54 | Ding dong call bell |
| 55 | Musical call bell |
| 56 | 2.5 mfd fan capacitor |
| 57 | Side holder for FTL/T5 |
| 58 | Side holder for pin type CFL |
| 59 | 3mm thick bakelite sheet |
| 60 | 5 amps power top:- |
| 61 | 15 amps power top:- |
| 62 | 32 amps DP kit kat switch:- |
| 63 | Gong bell |
| 64 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required. |
| 65 | 102mm x 102mm (4\\" X 4\\") :- |
| 66 | 102mm x 178mm (4\\" X 7\\") :- |
| 67 | 152mm x 203mm (6\\" X 8\\") :- |
| 68 | 203mm x 254mm (8\\" X 10\\") :- |
| 69 | 203mm x 300mm (8\\" X 12\\") :- |
| 70 | 254mm x 300mm (10\\" X 12\\") :- |
| 71 | 300mm x 380mm (12\\" X 15\\") :- |
| 72 | Supplying and fixing of the following sizes PVC switch boards with cover etc. as required. |
| 73 | 75mm x 75mm (3\\" X 3\\") :- |
| 74 | 102mm x 102mm (4\\" X 4\\") |
| 75 | 102mm x 178mm (4\\" X 7\\") :- |
| 76 | 152mm x 203mm (6\\" X 8\\") :- |
| 77 | 203mm x 254mm (8\\" X 10\\") :- |
| 78 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 79 | 1-2 module plastic switch board:- |
| 80 | 3 module plastic switch board:- |
| 81 | 4 module plastic switch board:- |
| 82 | 6 module plastic switch board:- |
| 83 | 8 module plastic switch board:- |
| 84 | 12 module plastic switch board:- |
| 85 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 86 | 1-2 module :- |
| 87 | 3 module :- |
| 88 | 4 module :- |
| 89 | 6 module :- |
| 90 | 8 module :- |
| 91 | 12 module :- |
| 92 | 16 module :- |
| 93 | 18 module :- |
| 94 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 95 | 6/10 amps one way SP switch (1M) :- |
| 96 | 6/10 amps two way SP switch (1M) :- |
| 97 | 16/20 amps one way SP switch (1M) :- |
| 98 | Bell push SP (1M) :- |
| 99 | 3 pin 6/10 amps socket outlet (2M):- |
| 100 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 101 | 4 step fan regulator (1M):- |
| 102 | Blank plate (1M):- |
| 103 | Louvers/opaque type LED foot lamp (4M):- |
| 104 | 20/25 amps single phase motor starter switch (2M):- |
| 105 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 106 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 107 | Supply and fixing of 32mm x 6 mm GI strip on walls/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 108 | Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 109 | Supply and fixing of 32mm x 6 mm Copper strip on walls/ floor of the building for hoizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 110 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 111 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 112 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 113 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 114 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:- |
| 115 | Supplying & installation of 450 mm sweep wall mounting air circulator including connection etc as required:- |
| 116 | Supplying & installation of 450 mm sweep AC padestal air circulator including connection etc as required:- |
| 117 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 118 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 119 | Supplying & installation of 380 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 120 | Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 121 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 122 | Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 123 | Supplying & installation of metalic fan clamp box of standard size with 3mm thick bakelite/plastic cover as required:- |
| 124 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required :- |
| 125 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required. |
| 126 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 127 | Supplying and fixing of following room heater complete with 15 amps top including necessary connection etc as required. |
| 128 | 1000 watt fixed type room heater:- |
| 129 | 1000/1500/2000/2500 watt blower type room heater:- |
| 130 | Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required. |
| 131 | 10 litre storage capacity:- |
| 132 | 15 litre storage capacity:- |
| 133 | 25 litre storage capacity:- |
| 134 | Supplying and fixing of following accessories for water heater including connection etc as required as per direction of site Engineer. |
| 135 | Heating element / Coil |
| 136 | Thermostat/ Thermal cutout. |
| 137 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 138 | Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL, electronic ballast and high quality reflector cover : - |
| 139 | Supplying and fixing of the following Lamps & accessories including connection etc. as required. |
| 140 | 15 watt GLS lamp:- |
| 141 | 25/40/60/100 watt GLS lamp:- |
| 142 | 200 watt GLS lamp:- |
| 143 | 18/20 watt T-8/T-12 FTL lamp:- |
| 144 | 14/28 watt T-5 lamp:- |
| 145 | 11 watt CFL 2 pin/4pin PL lamp :- |
| 146 | 18 watt CFL 2 pin/4pin PL lamp :- |
| 147 | 36 watt CFL 4pin PL lamp :- |
| 148 | 36/40 watt electronic ballast:- |
| 149 | 70 watt ballast for HPSV/MH lamp:- |
| 150 | FTL starter:- |
| 151 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 152 | Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:- |
| 153 | Recessed/Surface mounted 2ft x 2ft decorative 36 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 154 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 155 | Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 156 | Recessed round/Square shaped 15 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 157 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 158 | 36 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 159 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 160 | 120 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 161 | 150 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 162 | 180 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 163 | 9 watt/10 watt LED Bollard light with high quality polycarbonate diffuser (IP 65):- |
| 164 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 165 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 166 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 167 | 20 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 168 | 30 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 169 | 18 watt LED PL-Lamp with integral driver and high quality polycarbonate diffuser :- |
| 170 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 171 | 100 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):- |
| 172 | 200 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):- |
| 173 | 300 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx150mm):- |
| 174 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 175 | 63 amps kitkat porcelain fuse unit with base(rewireable):- |
| 176 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 177 | 200/250 amps kitkat porcelain fuse unit with base(rewireable):- |
| 178 | 300/320 amps kitkat porcelain fuse unit with base(rewireable) with extended strip:- |
| 179 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 180 | (2+4) / 6 way SPN MCB DB (double door):- |
| 181 | (2+6) / 8 way SPN MCB DB (double door):- |
| 182 | (2+10) / 12 way SPN MCB DB (double door):- |
| 183 | 4 way horizontal TPN MCB DB (Double door):- |
| 184 | 6 way horizontal TPN MCB DB (Double door):- |
| 185 | 8 way horizontal TPN MCB DB (Double door):- |
| 186 | 12 way horizontal TPN MCB DB (Double door):- |
| 187 | 4 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 188 | 6 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 189 | 8 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 190 | 12 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 191 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 192 | 6 to 32 amps SP MCB:- |
| 193 | 6 to 32 amps DP MCB:- |
| 194 | 6 to 32 amps TP MCB:- |
| 195 | 6 to 32 amps TPN MCB:- |
| 196 | 6 to 32 amps FP MCB:- |
| 197 | 40 amps DP MCB:- |
| 198 | 40/50/63 amps TP MCB:- |
| 199 | 40/50/63 amps TPN MCB:- |
| 200 | 40/50/63 amps FP MCB:- |
| 201 | MCB Module RYB indicator light:- |
| 202 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 203 | 40 amps DP isolator:- |
| 204 | 63 amps DP isolator:- |
| 205 | 40 amps TP isolator:- |
| 206 | Supplying & installation of RCCB (sensitivity 30mA to 300mA) of following ratings in the existing MCB DB including connection etc as required:- |
| 207 | 16 to 40 amps DP RCCB:- |
| 208 | 63 amps DP RCCB:- |
| 209 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 210 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 211 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 212 | 125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 213 | 160 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 214 | 200 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 215 | 200 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 216 | 250 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 217 | 320 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 218 | 400 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 219 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 220 | 3 core 4 Sq mm |
| 221 | 3.5 core 25 Sq mm |
| 222 | 3.5 core 35 Sq mm |
| 223 | 3.5 core 50 Sq mm |
| 224 | 3.5 core 70 Sq mm |
| 225 | 3.5 core 95 Sq mm |
| 226 | 3.5 core 120 Sq mm |
| 227 | 3.5 core 150 Sq mm |
| 228 | 3.5 core 185 Sq mm |
| 229 | 3.5 core 240 Sq mm |
| 230 | 3.5 core 300 Sq mm |
| 231 | 4 core 4 Sq mm |
| 232 | 4 core 6 Sq mm |
| 233 | 4 core 10 Sq mm |
| 234 | 4 core 16 Sq mm |
| 235 | 4 core 25 Sq mm |
| 236 | 4 core 35 Sq mm |
| 237 | 4 core 50 Sq mm |
| 238 | 4 core 70 Sq mm |
| 239 | 4 core 95 Sq mm |
| 240 | 4 core 120 Sq mm |
| 241 | 4 core 150 Sq mm |
| 242 | 4 core 185 Sq mm |
| 243 | 4 core 240 Sq mm |
| 244 | 4 core 300 Sq mm |
| 245 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 246 | 25 sq mm |
| 247 | 35 sq mm |
| 248 | 50 sq mm |
| 249 | 70 sq mm |
| 250 | 95 sq mm |
| 251 | 120 sq mm |
| 252 | 150 sq mm |
| 253 | 185 sq mm |
| 254 | 240 sq mm |
| 255 | 300 sq mm |
| 256 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 257 | 25 sq mm |
| 258 | 35 sq mm |
| 259 | 70 sq mm |
| 260 | 95 sq mm |
| 261 | 120 sq mm |
| 262 | 150 sq mm |
| 263 | 185 sq mm |
| 264 | 240 sq mm |
| 265 | 300 sq mm |
| 266 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 267 | 1.5 sqmm - 4 sqmm Cable:- |
| 268 | 4 sqmm - 10 sqmm Cable:- |
| 269 | 10 sqmm - 16 sqmm Cable:- |
| 270 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 271 | 25 mm dia |
| 272 | Supplying and fixing of 20 mm MS pipe as down rod for installation of luminaries with necessary accessories etc as required. |
| 273 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 274 | Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:- |
| 275 | Supplying of ‘U’ clamp made with 40mm x 6 mm MS flat and fixing with necessary fasten nuts including painting etc as required. |
| 276 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 277 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 278 | Supplying & installation of following power contactors including necessary connection etc as required:- |
| 279 | 3 pole 9 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 280 | 3 pole 12 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 281 | 3 pole 18 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 282 | Cleaning of existing ceiling fan/luminaries. |
| 283 | Supplying and fixing of following Cable tray made of hot dip galvanised iron:- |
| 284 | 30 mm x 50mm:- |
| 285 | 54 mm x 100 mm |
| 286 | 105mm x 150mm |
| 287 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 288 | Centering shuttering including struttings, propping etc.and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 289 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 290 | Neat cement punning:- |
| 291 | Supplying installation and fixing of following 10 watt LED Cross Pin LAMPS including necessary connection etc. as required. (OSRAM Make: Model : LVSTICK 10W/830 220-240V G24D APM) |
| 292 | 10 watt LED Cross PIN |
| 293 | Supplying, installation and fixing of 18/20W LED tubelight with industrial compact batten suitable for single tubelight with integral LED Driver in double side connection etc as required:- (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 294 | Supplying of 8 foot (7 Step + 1 platform) Height Aluminum C shaped Folding Stool type ladder having 63 mm Flat Step with step to step distance of 12 inch with platform 400mm x 300 mm heavy duty complete with rubber shoes side plug lock: |
| 295 | Supplying of 11 foot (10 Step + 1 platform) Height Aluminum C shaped Folding Stool type ladder having 63 mm Flat Step with step to step distance of 12 inch with platform 400mm x 300 mm heavy duty complete with rubber shoes side plug lock: |
| 296 | Supplying of 14 foot (13 Step + 1 platform) Height Aluminum C shaped Folding Stool type ladder having 63 mm Flat Step with step to step distance of 12 inch with platform 400mm x 300 mm heavy duty complete with rubber shoes side plug lock: |
| 297 | Hiring of Skilled Wireman/Electrician for providing of round the clock duty for all days of a month beyond Government duty hours including all Govt. holidays for upkeeping & mtc of the existing electricals installations i.e light fixtures, fan, outdoor lights, feeder pillars main electrical panel, distribution panel including restoration/replacement of defective components along with addition/altercation IE installations etc. as per the directions of the Engineer-In-Charge. |
| 298 | 01 (One) Electrician/ Skilled wireman for 01 (One) shift in a day. (276 Working Days) |
| 299 | 01 (One) Electrician/Semi-skilled wireman for 01 (One) shift in a day (365 Days a Year) Please Enable Macros to View BoQ information |