| 1 | Repair and maintenance of 10 HP/12.5 HP Motor suitable for 5000 GPH capacity submersible pump set by complete dismantling in/c providing & fitting fixing of PVC (IS: 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 2 | Repair and maintenance of 15 HP/17.5 HP Motor suitable for 7500 GPH capacity submersible pump set by complete dismantling in/c providing & fitting fixing of PVC (IS: 8783-1978) Insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 3 | Repair and maintenance of 20/22.5 HP Motor suitable for 10000 GPH capacity submersible pump set by complete dismantling in/c providing & fitting fixing of PVC (IS: 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 4 | Repair and maintenance of submersible Motor suitable for submersible pump set by complete dismantling in/c providing & fitting fixing of PVC (IS: 8783-1978) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 5 | i) 1.0 HP Motor suitable for 1000 GPH capacity submersible pump set. |
| 6 | ii) 2.0 HP Motor suitable for 2000 GPH capacity submersible pump set |
| 7 | iii) 3.0 HP Motor suitable for 2000/2500 GPH capacity submersible pump set |
| 8 | Repair of pump 2HP/3HP (1500/2000 GPH capacity) in/c submersible pump dismantling & reassembling of new impeller casing, ring bush & bearing etc. fitting fixing satisfactory trial run complete asper direction of the Engineer-in-charge. |
| 9 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge. |
| 10 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. |
| 11 | 16 sqmm |
| 12 | 35 sqmm |
| 13 | 50 sqmm |
| 14 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 15 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 16 | Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. |
| 17 | i) For 3-phase connection with 4.00 mtr. Long G.I. pipe |
| 18 | Providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge. |
| 19 | Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge. |
| 20 | i) 5-15 kVAr 440 V |
| 21 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge. |
| 22 | i) 63 Amps |
| 23 | ii) 100 Amps |
| 24 | iii) 200 Amps |
| 25 | iv) 250 Amps |
| 26 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. |
| 27 | i) 25 HP/18.5 kw Relay range within 13-21 + 10% |
| 28 | ii) 35 HP/26 kw Relay range within 20-32 + 10% |
| 29 | iii) 50 HP/37 kw Relay range within 28-42 + 10% |
| 30 | Providing and fitting fixing of re-wireable porcelain type extended cutout of Havels make as per direction of the Engineer in charge. |
| 31 | i) 200 Amps. |
| 32 | ii) 320 Amps |
| 33 | Providing and fitting fixing of size 70 sq mm dowels copper tube terminal heavy dury ( cat No.CUS285) as per direction of the Engineer In charge. ( Dowell Make) |
| 34 | Providing and fitting fixing Single phasing preventor +selectable under voltage +selectable over voltage on delay 5 sec & off delay 15 sec phase asymmetry 10% L & T /BCH/HAVELS/Siemens etc. make complete as per specification and direction of the Engineer-in-charge. |
| 35 | Providing and fitting fixing 3 pole contactors type ML size Fr 1 AC 3 rating (A) 25 AC 1 Rating (A) 25 type ML 1.5 AUX. contacts 2 No. + 2 NC Cat No. SS91851 of L & T Make as per direction of Engineer in charge. |
| 36 | Providing and fitting fixing 3 pole contactors type ML size Fr 2 AC 3 rating (A) 32, AC 1 Rating (A) 40 type ML 2 AUX. contacts 2 No. + 2 NC Cat No. SS90701 of L & T Make as per direction of Engineer in charge. |
| 37 | Providing and fitting fixing 3 pole contactors type ML size Fr 2 AC 3 rating (A) 40, AC 1 Rating (A) 45 type ML 3 AUX. contacts 2 No. + 2 NC Cat No. SS90721 of L & T Make as per direction of Engineer in charge. |
| 38 | Providing and fitting fixing spare contact kit type ML 1.5 cat no.SS95305 of L & T make as per direction of the Engineer in charge. |
| 39 | Providing and fitting fixing spare contact kit type ML 2 cat no.SS95307 of L & T make as per direction of the Engineer in charge. |
| 40 | Providing and fitting fixing spare contact kit type ML 3 cat no.SS95309 of L & T make as per direction of the Engineer in charge. |
| 41 | Providing and fitting fixing spare coil type ML 1.5 cat no.SS90873 of L & T make as per direction of the Engineer in charge. |
| 42 | Providing and fitting fixing spare coil type ML 2/ML 3 cat no.SS90545 of L & T make as per direction of the Engineer in charge. |
| 43 | Providing and fitting fixing Thermal overload Relay type ML direct mounting of ML 2/ML 3 contactor ( directly operated) Relay Range (A) 20-32/28-42 (cat no. SS9185900EO, SS9185900FO) of L & T make as per direction of Engineer in charge. |
| 44 | Providing and fitting fixing Thermal overload Relay type ML direct mounting of ML 1.5 contactor ( directly operated) Relay Range (A) 10-15 (cat no. SS9185800BO) of L & T make as per direction of Engineer in charge. |
| 45 | Providing and fitting fixing Electronic timer type ST 100 operating voltage 360-415 V, 50 Hz for 3-30 secs of L& T make suitable for ML 2/ ML 3 L & T make starter ( cat no.ST803290000) as per direction of the Engineer in charge. |
| 46 | Providing and fitting fixing Push Buttom unit suitable for MN/DOL/FASD L & T make starter cat no.SS939410000 as per direction of the Engineer in charge. |
| 47 | Providing and fitting fixing Cylindrical fuse link HF size 14x51 rated current (A) 63 suitable for type FN 63/FNX 63 S-D-F and for HC fuse base of L&T make no. SF90158 as per direction of Engineer in charge. |
| 48 | Providing and fitting fixing DIN type fuse link HN size 00 rated current (A) 100 suitable for type HN 100/125/160/FNC 125/160 S-D-F and for HB fuse base cat no.SF94030 of L & T make as per direction of the Engineer in charge. Please Enable Macros to View BoQ information |