| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-- |
| 2 | Short Point :- |
| 3 | Medium Point : |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 7 | 2 X 1.5 sq mm:- |
| 8 | 2 X 2.5 sq mm:- |
| 9 | 2 X 4 sq mm:- |
| 10 | 2 X 6 sq mm |
| 11 | 4 X10 sq mm |
| 12 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 13 | 1 X 1.5 sq mm:- |
| 14 | 1 X 2.5 sq mm:- |
| 15 | 1 X 4 sq mm:- |
| 16 | 2 X 4 sq mm:- |
| 17 | 4 X 70 sq mm:- |
| 18 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 19 | 15 amps power top:- |
| 20 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 21 | 1-2 module GI switch board:- |
| 22 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 23 | 1-2 module :- |
| 24 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 25 | 3/6 pin 25 amps socket outlet (2M):- |
| 26 | 20/25 amps single phase motor starter switch (2M):- |
| 27 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 28 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 29 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 30 | Providng and laying 15mm dia (medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 31 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 32 | 200 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx120mm):- |
| 33 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 34 | 200 amps 415 volts TPN main switch (rewireable):- |
| 35 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 36 | 200/250 amps kitkat porcelain fuse unit with base(rewireable):- |
| 37 | Supply and fixing of surface mounted 18/20 watt LED tube luminaire with powder coated finished 0.5 mm thick CRCA steel sheet housing including 1 no 18/20 watt LED tube having minimum system lumen output of 120 Lumens/watt & life expectancy of 50,000 burning hours with integral driver having 2 kV SPD and polycarbonate diffuser including connection etc as required (with LM79 report from NABL accredited lab):- |
| 38 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB /Isolator/ RCCB(SP/SPN/DP/TP/TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 39 | (2+4)/6 way SPN MCB DB (double door) |
| 40 | 4 way horizontal TPN MCB DB (Double door):- |
| 41 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as require:- |
| 42 | 6 to 32 amps SP MCB:- |
| 43 | 6 to 32 amps DP MCB:- |
| 44 | 40/50/63 amps TP MCB:- Please Enable Macros to View BoQ information |