| 1 | Taking out/pumping out sewage water from septic tank/soakage well from vehicle with attached water tank of 3000 ltr capacity with mechanical pump and sucking and removing and dumping of the same place at the place marked for the purpose by the authority controlling the area, distance for removal from original point to disposal point is marked by the GE complete all as specified and directed. |
| 2 | M & L second class soft wood in scantling clean swan below or above ground level upto four storey building, including dismantling timber scantling 40 Sqcm and over in section in any position in unframed work complete all as specified and directed. |
| 3 | All as per item 2 above but except timber including Dismantling timber scantling 40 Sqcm and over in section in any position in unframed work. |
| 4 | S & F in repair Vitreous China Urinal, Half stall type, white with grating and union for discharge pipe including providing and fixing plugs with and including 60mm long brass screws, pointing around urinal back in cement with PVC 32mm dia waste pipe & waste coupling including spreader complete all as specified and directed |
| 5 | S&F in repairs Vitreous China Wash down water closet pan (Pedestal pattern), white including plastic water closet seat and cover closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device & including P or S trap and connection to trap and to the flushing system anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 6 | S&F in repairs Vitreous China Ware Wash hand basin white flat back size 550mmx400mm including pedestal, cutting for and pinning ends of brackets or erecting stand including necessary PVC outlet pipe, CP coupling 32mm dia complete all as specified and directed. |
| 7 | S&F in repairs vitreous China squatting pan 'Orissa' pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing system anti syphonage pipe etc complete all as specified and as directed. |
| 8 | S&F in repairs PVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr cap white with flush pipe & all fitting complete all as specified and directed. |
| 9 | S&F in repair Stop valves cast copper alloy fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore pipe complete all as specified and directed. |
| 10 | S&F in repair Bib taps cast copper alloy, chromium plated, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed. |
| 11 | S&F in repairs pillar tap cast copper alloy, fancy type with capstan heads chromium plated screwed down with high pressure with or without lettered hot or cold with long screwed, shanks and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 12 | S&F in repairs 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 13 | S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 14 | S&F in repairs Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 15 | S&F in repairs tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 16 | S&F 500 Ltr capacity PVC water storage tank (cylindrical vertical with closed top ) and fixed in position all as specified in SSR Part -I, including dismantling of old unserviceable tank complete all as specified and directed. |
| 17 | S&F in repair ball valves, high pressure, with polythene float and fly nut complete, 20mm bore complete all as specified and directed. |
| 18 | S&F in repair 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends complete all as specified and directed. |
| 19 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 20 | S&F in repair Grating doom 100mm dia of PTMT (minimum weight 25gms) suitable for floor taps complete all as specified and directed. |
| 21 | S&F in repairs health faucet (hand shower) chromium plated complete all as specified and as directed. complete all as specified and directed. |
| 22 | S&F in repairs towel ring of brass chromium plated complete all as specified and as directed. |
| 23 | S&F in repairs kitchen sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx460mm bowl size 410 mmx330mmx 160mm etc complete all as specified and as directed. |
| 24 | S&F GI tube 15 mm dia medium grade galvanised with all fittings laid in floors /wall etc. including taking up or down 15mm dia GI steel tubing and connections, complete all as specified and as directed. |
| 25 | S&F GI tube 20 mm dia medium grade galvanised with all fittings laid in floors /wall etc. including Taking up or down 20mm dia GI steel tubing and connections, complete all as specified and as directed. |
| 26 | M&L for lagging to pipes 15mm bore used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144Kg/Cum conforming to IS-9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh and covered with 0.01mm aluminium foil, complete all as specified and directed. |
| 27 | M&L for lagging to pipes 20mm bore used in internal water supply or plumbing all round with 25mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144Kg/Cum conforming to IS-9842 provided with chicken mesh wire netting 25 gauge, 20mm mesh and covered with 0.01mm aluminium foil, complete all as specified and directed. |
| 28 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls including Dismantling of rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed. |
| 29 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches including dismantling of rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed. |
| 30 | S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door complete all as specified and directed. |
| 31 | S & F bend suitable for 110mm dia PVC (SWR) pipe complete all as specified and as directed. |
| 32 | S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified and directed. |
| 33 | S&F PVC (SWR) reducers any radius 110mm bore complete all as specified and directed. |
| 34 | S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access complete all as specified and directed. |
| 35 | S&F 110mm bore PVC (SWR) junction, single (single Y) equal or unequal with door access complete all as specified and directed. |
| 36 | S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed. |
| 37 | M&L for PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 38 | M&L for cleaning of sewage lines of 100mm /150mm bore including manholes by means of cleaning rods through manholes to manholes, including dewatering (if any) taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50 m from nearby living ACCN and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and cover the pit, out of Garrison in a closed container if living area/Cook house/Office complex not less than 50m from where work is progressed complete all as specified and directed. Note:-Cost of earth work in the pit is deemed to be included in the unit rate quoted by tenderer. |
| 39 | M&L for cleaning/removal of blockage and removing deposited sludge/liquid materials, foreign materials from manholes, pipe lines through vacuum pressure Jet Machine complete all as specified and directed. |
| 40 | M&L for repairs to Punctures of pipe line including excavation in soft/loose soil, bedding, relaying of pipe and make good the earth excavated area including redressing complete all as specified and directed. |
| 41 | M&L for cleaning of blockage from Water Closet (Indian or European), trap & CI pipe line upto first manhole manually by rodding and removing the deposited sludge/solid/liquid material outside MD land, complete all as Specified and directed. |
| 42 | Cleaning of blockage from Floor/Nahni trap of kitchen/Bathroom upto but excluding gully trap manually by rodding and removing the deposited sludge/solid/liquid material outside MD land complete all as specified and directed. |
| 43 | M&L for dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth and disposing same out of cantonment area in a closed container including taking off manhole covers and putting back the same after cleaning/removing the liquid waste material of septic tanks and cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150 x 200mm and finally spraying unslaked lime (bleaching powder), dry, around and over the septic tank all as directed and the entire satisfaction of GE. Note :-1. Qty of liquid sludge shall be measured for payment under this item. 2. Arrangement of land for the disposal of waste is complete responsibility of contractor. |
| 44 | Demolition of cement concrete (reinforced) in ground floors and paving’s n exc. 15cm thick (Below or above ground level) complete all as specified and directed. |
| 45 | M&L for precast Cement Concrete (1:2:4) type B1 using 20mm graded aggregate as in landings, cover slab (for manhole etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces set in CM (1:4) complete all as specified and directed. |
| 46 | M & L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed. Note:-Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under for fair finished surfaces of concrete. |
| 47 | M&L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm die or securing with clips quality complete all as specified and directed. |
| 48 | M&L for excavation in trenches n.exc 1.5 m wide & n.exc 1.5 deep for foundation for shafts, wells, cesspits, manholes etc not exc 10 sqm on plan and getting cut in sofr/loose soil complete all as specified and directed. |
| 49 | M&L for PCC 1:4:8 type C-2 using 40 mm graded stone aggregate for foundations, filling and mass concrete complete all as specified and directed. |
| 50 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for bedding and coping and casting of post including necessary form work complete all as specified and directed. |
| 51 | M&L for returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed |
| 52 | M&L for removal of excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 53 | S&F mild steel round or square bars conforming to F-410 W (Gde E-250) Quality A work in rungs, hooks, handles, for drain covers, hold fast & small articles complete all as specified and directed |
| 54 | M&L for demolition cement concrete (un reinforcement) in ground floor and paving n exc 15 cm thickness (below or above ground level) & removal complete all rubbish materials complete all as specified and directed |
| 55 | M&L for extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete, using extra cement including forms/moulds/mitred stopped ends etc complete all as specified and directed |
| 56 | M&L for cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed |
| 57 | M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slabs, of any thickness, size or shape including necessary form work, set and jointed in cement mortar (1:4) complete all as specified and directed. |
| 58 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortal 1:6 including Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars & precast concrete masonry etc complete all as specified & directed. |
| 59 | M&L for preparation of previously treated surfaces/old surface of wall and applying one coat cement base paint on old surface of wall complete all as specified and directed |
| 60 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed. |
| 61 | M&L 15mm thick cement plaster on external surface in CM 1:4 mixed with WPC 3% by weight of cement including finishing fair & even all as including taking down cement or cement lime plaster, of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 62 | Supply only water proofing compound as per IS-2645 complete all as specified and directed |
| 63 | M&L for 15mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and directed |
| 64 | S&F for 75mm to 90 mm thick Steel Fibre Reinforced (SFRC) cover with iron frames (Light duty) complying to the standard specifications as mentioned in the IS 12592 BIS standard, minimum load bearing capacity 2.5 ton, in square, rectangular or circular shape complete all as specified and directed. |
| 65 | M&L for providing and fixing in repair concertina coil fencing with punched tape concertina coil 600 mm dia 10m openable length ( total length 90m) having 50 nos rounds per 6 m length, up to 3.0m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tired with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed wire tape (R.B.T)/spring core (2.5 mm thick) wire of high tensile strength of 165kg/sq.mm with tape (0.52 mm thick 0 and weight 43.478 gm/metre complete all as specified and directed. Note:-Cost of M.S. angle, CC Blocks shall be measured and paid separately. |
| 66 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. and in any mortar complete all as specified and directed. |
| 67 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed |
| 68 | M&L for 20 cm x 20cm x 25 mm thick Chequered cement concrete tiles (in any colour & shape), set, jointed and pointed in neat cement slurry in floors with grey cement & no pigment over 20 mm screed bed in CM 1:6 complete all as specified and directed. |
| 69 | M&L for 75mm thick plain cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as sub base floor complete all as specified and directed |
| 70 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed |
| 71 | M&L for hardcore of gauge (broken bricks) n exc 63mm deposited spread levelled in layers n exc 15 cm thick watered and rammed to a true surface with gauze broken boulder exc 90 cm complete all as specified and directed |
| 72 | M & L cement concrete type B-1 1:2:4 (20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed copings, packing around interlocking paver. and fixing of Y angle section complete all as specified and directed. |
| 73 | Dismantling structural steel work including doors gates etc complete all as specified and directed |
| 74 | Excavation in post hole each n. exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layer n. exc 25 cm, watering and removing surplus soil to a distance n. exc 50m and making good surfaces in soft/loose soil complete all as specified and directed |
| 75 | M&L for PCC (1:3:6) type C-2 as in foundation filling and mass concrete for MS angle posts complete all as specified and directed |
| 76 | Dismantling fencing wire mass any type complete all as specified and directed |
| 77 | S&F MS angle iron fixed independently without connecting plates complete as in fencing post or struts/ 'Y' section including cutting shape as directed, drilling holes, welding notching wire including embedding in concrete and screwing conforming to Fe-290 Gde E-165 etc complete all as specified and directed |
| 78 | Fixing Only chain Link Fencing Including Line wire any Mesh Size and type to any type of standard rails straining bolts etc including provision of binding wire complete all as specified and directed |
| 79 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed |
| 80 | Dismantling of old barbed wire etc complete all as specified and directed |
| 81 | S&F in repairs GI 2 standard steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of stranded rails, straining bolts including securing or tying at crossing with and provision of galvanised MS wire, staples or steel pins etc complete all as specified and directed. Note:-Each line of wire to be measured. |
| 82 | M&L for mild steel bars 10mm dia Round and plain Bars and over cut to length bent to shape required including cranking bending for Support of Chain Link fencing including nut and bolt Fe-410-W) (Gde.E-250) Part- I quality-A complete all as specified and directed |
| 83 | M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290.Gde-E-165 including ornamental and intricate design and portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified and directed |
| 84 | M&L for preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 85 | M&L RCC work M-25 design mix (using 20mm graded crushed stone aggregate) as in slab supported in walls cantilevers etc complete all as specified and directed. |
| 86 | M&L form work as in suspended slab, such as roof slabs, floor slabs, landings and similar work, not exceeding 20mm thick (Horizonal or sloping) complete all as specified and directed |
| 87 | S&F Pre-painted galvalume aluminium Zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screw including necessary scaffolding, upto four storey building complete all as specified and directed by Engr-in-Charge. (Note : Cost of scaffolding work for fixing of roof sheet to be included in the unit rate quoted by tenderer) including dismantling plain or corrugated steel sheeting, any gauge ,thickness including Nainital or similar pattern roof covering including necessary scaffolding, any type, any location/height complete all as specified and directed |
| 88 | S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, upto four storey building complete all as specified and directed. Note: Cost of scaffolding work for fixing of roof sheet to be included in the unit rate quoted by tenderer) including dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering including necessary scaffolding, any type, any location/height complete all as specified and directed |
| 89 | M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and directed. |
| 90 | M&L for Preparation of old painted surfaces and applying two coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 91 | M&L for Preparation of old painted surfaces and applying two coat of synthetic enamel paint on steel surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 92 | M&L for Preparation of old painted surfaces and applying one coat of synthetic enamel paint on steel surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 93 | S&F 20mm thick 2nd class softwood boarding, planed one side , with butt joints and fixed with nails in facia eaves boarding including Dismantling of boarding of any description fitted in any position with nails complete all as specified and directed |
| 94 | M&L for 2nd class softwood weather boarding clean sawn, plain 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps including Dismantling of boarding of any description fitted in any position with nails complete all as specified and directed |
| 95 | All as per item No.94 above, but except boarding, including Dismantling of boarding of any description fitted in any position with nails complete all as specified and directed |
| 96 | S&F sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane including Hacking out old broken glass (any thickness, size quality of description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. |
| 97 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 including demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 98 | M&L for random rubble masonry using sand stone uncoursed well bonded bedded and solidly hearted built in CM 1: including demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 99 | All as per item No 98 above but except stone including demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 100 | M&L for rendering 15mm thick on stone/brick masonry surfaces or other than fair faces in cement mortar 1:4 finished even and smooth (without using extra cement) including Taking down of cement plaster of any description including racking out of joints hacking for keys and scrubbing down with water etc complete all as specified and directed |
| 101 | M&L for rendering 15mm thick on stone/brick masonry surfaces or other than fair faces in cement mortar 1:6 finished even and smooth (without using extra cement) including taking down of cement plaster of any description including racking out of joints hacking for keys and scrubbing down with water etc complete all as specified and directed |
| 102 | M&L for preparation of new or undecorated surfaces of wall and applying 3 mm thick wall care putty and rubbing with sand paper to achieve a level and smooth to wall and applying two coats of acrylic distemper over a coat of primer complete all as specified and directed. |
| 103 | M&L for preparation of old/undecorated surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 104 | M&L for complete removal of existing treatment of any description and applying 3 mm thick wall care putty and rubbing with sand paper to achieve a level and smooth to wall and applying two coats of acrylic distemper over a coat of primer complete all as specified and directed. Please Enable Macros to View BoQ information |