| 1 | Providing labour for deployment of team consistiing of one electrion(ITI qualified) and two helper and providing transport and T&P for locating the fault in HT/LT line in OH/UG Line/cable by visual inspection recce of faulty area and repairs to the fault by means of replacement of Unservicable Jumpers /Fuse wires / Burnt lugs/all type of insulator/ MCCB etc. inclusive restraining of broken/loose ACSR conductorss/Earth wire etc Making tamporary connection if required to make the countinity of supply , The Cable required shall be given by department from AGE E/M store for temporary resume the power supply.The area coming under Sub Station No. 01, 2,05 & 5 ( Map pocket) shall be covered under the subject work complete all as directed by Engineer-in-chargeNote: (i) Materials requried for fault repairs will be measured under relevant items of this BOQ.(ii) Contractor will depute the dedicated team (one electician (ITI holder) and two helper)., Contractor will be responsible for the safety of his team deployed. No dispute regarding safety of person would be entertain later on. If any mishappening occures during rectifaction of fault in HT/LT lines contractor will be fully liable to bear all the expenses of staff deployed.(iii) Contractor will provide all set of T & P such as (a) HV (11000Volts) digital insulation tester (b) LV (1100V) digital insulation tester (c) Digital clamp meter up tp 1100 V and 1000Amps (d) Search light, rain coat (e) Cutting pliers (f) Screw Driver set, box spanner/wretched spanner (g) Allen key set (h) 11000V grade safety gloves, rubber boots, Safety belt and helmets, torch lights etc (i) Earthing rod (j) Bamboo ladder for desired height. (k) PVC tape roll (HV/LV) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, safety belt and helmets etc communication device (Mobile Phone) to deployed persons, Electrcian team (One Electrician (ITI Holder and Two Helper) as per site requirement. (iv) On intimation of any type of repair/maintenance work of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-Charge.(v) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indis for lodgging the complaints duly marked the location, time and date for earlier rectifications.(vi) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints.(vii) Contractor should also provide a dedicated supervisor for collection of complaints from SBA, JE, USER etc. He would be held responsible, in case complaints are not collected |
| 2 | Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-charge. |
| 3 | Supply only Disc type porcelain insulator, vitreous 145mm height and 255 dia ball and socket type, white, brown and green \\" Two in series\\" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge. |
| 4 | Supply only post insulator, porcelain, vitreous 150 mm high and 255 mm dia ball and socket type, white, brown or green, working pressure 11000 volts complete all as specified and directed by Engineer-in-charge. . |
| 5 | Supply only HT Jumper complete all as specified and directed by Engineer-in-charge. Note : Materials requried for fault repairs will be measured under relevant items included in BOQ. |
| 6 | Supply and fixing multi-jointed ACSR jumpers.(Length of one jumper not exceeding more than 3.0 mtrs) of HT over head lines with and incudingl XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed by Engineer-in-charge. |
| 7 | All as per item No. 6 here-in-before but with aluminium conductor single core cable of size 185 sqmm of size 185 Sqmm. |
| 8 | Supply and fixing in repalcement aluminium conductor steel reinforced any type conductor as per the site requirement including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed by Engineer-in-charge. |
| 9 | Material and labour for cutting through existing bituminous road /PCC/floor/approx size widthxdepth 50cm X 90cm along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and as directed by Engineer-in-charge. |
| 10 | Supply and fixing aluminium cable lugs any type suitable for cable of size 10 sqmm including necessary crimping with crimping tool complete all as specified and directed by Engineer-in-charge. |
| 11 | All as per serial item No.10 here-in-before but for cable of size 16 sqmm complete all as specified and directed by Engineer-in-charge. |
| 12 | All as per serial item No.10 here-in-before but for cable of size 25 sqmm complete all as specified and directed by Engineer-in-charge. |
| 13 | All as per serial item No.10 here-in-before but for cable of size 35 sqmm complete all as specified and directed by Engineer-in-charge. |
| 14 | All as per serial item No.10 here-in-before but for cable of size 50 sqmm complete all as specified and directed by Engineer-in-charge. |
| 15 | All as per serial item No.10 here-in-before but for cable of size 70 sqmm complete all as specified and directed by Engineer-in-charge. |
| 16 | All as per serial item No.10 here-in-before but for cable of size 95 sqmm complete all as specified and directed by Engineer-in-charge.. |
| 17 | All as per serial item No.10 here-in-before but for cable of size 120 sqmmcomplete all as specified and directed by Engineer-in-charge. |
| 18 | All as per serial item No.10 here-in-before but for cable of size 150 sqmm complete all as specified and directed by Engineer-in-charge. |
| 19 | All as per serial item No.10 here-in-before but for cable of size 185 sqmm complete all as specified and directed by Engineer-in-charge. |
| 20 | All as per serial item No.10 here-in-before but for cable of size 240 sqmm complete all as specified and directed by Engineer-in-charge. |
| 21 | All as per serial item No.10 here-in-before but for cable of size 300 sqmm complete all as specified and directed by Engineer-in-charge. |
| 22 | All as per serial item No.10 here-in-before but for cable of size 400 sqmm complete all as specified and directed by Engineer-in-charge. |
| 23 | Repair/replacement of LT Jumper.(Length of one jumper not exceeding more than 2.00 mtrs) complete all as specified and as directed by Engineer-in-charge. |
| 24 | Connecting /disconnecting of air-conditioner in married officers quarters, OTM, offrs /JCOs /ORs Mess, auditorium hall , Ops room, Offices etc from the existing over head lines complete all as directed by Engineer in Charge. Note:- Cables and materials for connection will be provided by occupant /user of the accn |
| 25 | Replacement of HT fuse wire of any capacity/ size complete all as specified and as directed by Engineer-in-charge. Note : Fuse wires will be provided on requirement basis |
| 26 | Supply only the HT fuse wire of 40 Amps capacity. |
| 27 | Supply only the HT fuse wire of 63 Amps capacity. |
| 28 | Supply only the HT fuse wire of 100 Amps capacity. |
| 29 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 63 Amps with breaking capacity16 KA complete all as specified and directed by Engineer-in-charge. |
| 30 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 100 Amps with breaking capacity16 KA complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge. |
| 33 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply and fixing in repair MCCBs 4 pole, 415 V, adjustable thermal and magentic setting type, 630 Amps with breaking capacity 50 KA complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply and fixing in repair 240 V,10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carraying capacity 6- 32 Amp in the MCB,DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge. |
| 37 | Supply and fixing in repair 240 V,10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carraying capacity 32 Amp in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply and fixing in repair 415 V,10 KA 'B' curve miniature circuit breaker (MCB) of TPN and current carraying capacity 40-100 Amp in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge. |
| 39 | Providing following stationary required to lodge the complaint and keep the record, as per existing sample and as directed by Engineer-n-charge for a minimum period of 9 Months from the date of commencement of contract :- (i) Complaint Register/books as per sample. (ii) Complaint Slip/job card as per sample.(iii) Permit book as per sample.(iii) Other materials i.e. glue stick,pen, pencil, carbon paper and stainless steel scale one |
| 40 | Taking out from trenches worn out/ damaged / partially serviceable/unserviceable any size, LT and HT, PVC insulated armoured, heavy duty underground cable with aluminium conductors 1100/11000 volt Grade including bricks/ PCC covers,pipes etc. testing the cable in the presence of Engineer-in-charge to ascertain seviceability,segregating serviceable and unserviceable cable and relaying the existing serviceable cable after making the same serviceable condition with suitable size joint kits / jointing cable properly complete all as specified and as directed by Engineer-in-charge.Note: Excavation and earth work shall be measured and paid separately under relevant item of Sch 'A'/ BOQ (ii) Existing usable bricks/PCC cover will be resued and extra sand ,bricks will be measured and paid seprately. |
| 41 | Supply, laying, fixing, jointing and testing XLPE Insulated screnned, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor,11000 volts Earthed,grade cross section area 185 Sqmmx3 core, laid in trenches, under floor/roads passing through pipes / ducts / or fixed to walls etc including taking out old unserviceable cable of any size and make complete all as specified and directed. Note:- Excavation and earth work, sand cushnioning, PCC cover shall be measured and paid separetaly under respective items of this schedule. |
| 42 | Supply, laying, fixing, jointing and testing XLPE Insulated screnned, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor,11000 volts Earthed,grade cross section area 120 Sqmmx3 core, laid in trenches, under floor/roads passing through pipes / ducts / or fixed to walls etc including taking out old unserviceable cable of any size and make complete all as specified and directed. Note:- Excavation and earth work, sand cushnioning, PCC cover shall be measured and paid separetaly under respective items of this schedule. |
| 43 | Supply, laying, fixing, jointing and testing XLPE Insulated screnned, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor,11000 volts Earthed,grade cross section area 95 Sqmmx3 core, laid in trenches, under floor/roads passing through pipes / ducts / or fixed to walls etc including taking out old unserviceable cable of any size and make complete all as specified and directed. Note:- Excavation and earth work, sand cushnioning, PCC cover shall be measured and paid separetaly under respective items of this schedule. |
| 44 | Supply, laying, fixing, jointing and testing XLPE Insulated screnned, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor,11000 volts Earthed,grade cross section area 10 Sqmmx4 core, laid in trenches, under floor/roads passing through pipes / ducts / or fixed to walls etc including taking out old unserviceable cable of any size and make complete all as specified and directed by Engineer-in-charge. Note:- Excavation and earth work, sand cushnioning, PCC cover shall be measured and paid separetaly under respective items of this schedule. |
| 45 | All as per item No. 44 here-in before but for cable of size 4 core 16 sqmm complete all as specified and directed by Engineer-in-charge. |
| 46 | All as per item No. 44 here-in before but for cable of size 4 core 25 sqmm complete all as specified and directed by Engineer-in-charge. |
| 47 | All as per item No. 44 here-in before but for cable of size 3.5core 70 sqmm complete all as specified and directed by Engineer-in-charge. |
| 48 | All as per item No. 44 here-in before but for cable of size 3.5 core 120 sqmm complete all as specified and directed by Engineer-in-charge. |
| 49 | All as per item No. 44 here-in before but for cable of size 3.5 core 240 sqmm complete all as specified and directed by Engineer-in-charge. |
| 50 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of cable, pipes and for foundation of poles/stay and struts etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge . |
| 51 | All as per serial item No. 50 here-in-before but for depth exceeding 1.5m but not exc 3.0 m complete all as specified and as directed by Engineer-in-charge |
| 52 | Returning, filling in soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and as directed by Engineer-in-charge. |
| 53 | Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed. |
| 54 | Material and labour for laying,s dry fine river sand in trenches, ducts as cushioning for ptotection of cable, 8 cm before laying of cable and 15 cm after laying of cable complete all as specified and as directed. Note:- For payment punned depth will be measured. |
| 55 | Supply and laying unreinforced precast concrete cable cover, class HVP,type-1 with peak,size 300mmx180mmx40mm laid flat adjacent and abutting to each other across the length of cable laid dry in trenches for protection of cable complete all as specified and as directed by Engineer-in-charge.. |
| 56 | Supply and laying unreinforced precast concrete cable cover, class LV ,type-1 ,size 250mmx150mmx40mm laid flat adjacent and abutting to each other across the length of cable laid dry in thenches for protection of cable complete all as specified and as directed. by Engineer-in-charge. |
| 57 | Supply and erecting in true verticle position of steel tublar swaged pole complete with cast iron base plate, finial taper plug ,bolt, nuts and screws as as specified type 410 SP-31 ( 9 metres long) conforming to relevent IS and applying two coats of aluminium paint over a coat of red oxide primer to the full length of the pole and two coats of bituminus paint inside and outside of pole from bottom portion upto 1.5 mtrs length (the portion to be embedded in ground) and marking the pole no with synthetic enamel paint of size as directed, provide and fixing 32 mm bore medium grade GI pipe 2.0 m long bend to shape fixed on pole with 02 Nos MS clamp of size 50x5 mm including nut s,bolts,washers etc for mounting LED security light complete including removing the existing broken poles complete all as specified and as directed by Engineer-in-chage .Note:- Excavation and PCC shall be measured and paid separetaly. |
| 58 | Material and labour for cable jointing kit 11 KV (earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 59 | Material and labour for cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 60 | Material and labour for cable jointing kit 11 KV (Earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 61 | Material and labour for cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 62 | Material and labour replacement of old rusted mild steel 100 mm bore,light grade, galvanized pipe laid in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and as directed by Engineer-in-charge. |
| 63 | Material and labour for cable jointing kit for 11KV( Earthed) grade for outdoor tremination Heat shrinkable type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed by Engineer-in-charge . |
| 64 | Material and labour for cable jointing kit for 11KV(Earthed) grade for outdoor tremination Heat shrinkable type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sq-300 sqmm complete all as specified and as directed Engineer-in-charge . |
| 65 | Material and labour for Cutting through existing bituminous/PCC road /PCC floor/approx size width 50cm X 90cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and as directed by Engineer-in-charge. |
| 66 | Material and labour for replacement of unserviceable steel tubular swaged pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial tape rplug, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block upto 1.5m height , each band of 300 mm height at 300 mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height complete all as specified and as directed by Engineer-in-charge.. Note:- Excavation and earth work, PCC works will be measured and paid separatly in respected items of this schedule. |
| 67 | Material and labour for cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregates for coping of poles / strutus or basements etc complete all as specified and as directed by Engineer-in-charge. |
| 68 | Material and labour for cement concrete 1:3 :6 type C-2, using 40 mm graded stone aggregate for foundation of poles / stays/strutus or basements etc complete all as specified and as directed by Engineer-in-charge. |
| 69 | Material and labour for cement concrete 1:4 :8 type D-2 ,using 40 mm graded stone aggregate for foundation of poles /stays/strutus or basements etc complete all as specified and as directed by Engineer-in-charge. |
| 70 | Material and labour for replacement of unserviceable cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of applying one primer coat ,one under coat and one finishing coat complete all as specified and as directed by Engineer-in-charge. |
| 71 | Material and labour for replacement of switch air break, gang operated, triple pole mechanically operated mounted on mild steel galvanized frame with operating rod of 20 mm bore medium grade ISI marked galvanized iron pipe worked from ground level for HT 11KV outdoor for horizontal or vertical mounting insulators and current rating 200 Amps including nuts,bolts and washers etc of required size, locking arrangement with locks and applying two coats of synthetic enamel paint over a coat of red oxide primer over mild steel work and making necessary electric connections complete all as specified and as directed by Engineer-in-charge. |
| 72 | Supply and fixing in replacement drop out fuse unit explusion type for out door air break gang oprated switch single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts, and washer etc. synthetic bounded fuse carray tube complete with line gap suitable for current carry capcity upto 100 Amps complete all as secified and as directed by Engineer-in-charge. |
| 73 | Material and labour for replacement of unserviceable 11 KV lightning arrestors (Set of three) explusion type complete with all fittings and necessary connection,transmission class, discharge capcity 65 kilo amps complete all as specified and as directed by Engineer-in-charge. |
| 74 | Material and labour for replacement of unserviceable anti climbing devices: Comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered including fixing clamps of MS flat 50x3 mm with nuts, bolts and washers etc complete all as specified and as directed. |
| 75 | Material and labour for replacement of unserviceable for danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size complrte all as specified ansd as directed by Engineer-in-charge. |
| 76 | Material and labour for cement concrete type B-1 (1:2:4) using 20 mm graded aggregate for coping of old poles / strutus or basements etc including demolition/dismantling the existing damaged cement concrete coping of old poles / strutus or basements etc complete all as specified and as directed. |
| 77 | Supply and fixing in replacement electronic driver with power factor correction suitable for 35/45/60 Watt LED street lights, input AC 85-300V, input frequency 50/60 Hz, output voltage DC 22-38V, output current 1500mA (+-) 5%, waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed by Engineer-in-charge. |
| 78 | Supply and fixing in replacement electronic driver with power factor correction suitable for 70/90/120 watt LED street lights, input voltage 70V AC to 300 V AC , power factor 0.99 (Unity) , over voltage 300 V cutt off , short and open circuit protection isolated, surge protection up to 10 to 12 Kv, maximum output voltage 55 Kv, maximum current up to 1.5a waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed by Engineer-in-charge. |
| 79 | Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed by Engineer-in-charge. |
| 80 | All as per serial item No. 79 here-in-before but LED street light fitting 90 Watt 230 V. |
| 81 | All as per serial item No. 79 here-in-before but LED street light fitting 70 Watt 230 V. |
| 82 | All as per serial item No. 79 here-in-before but LED street light fitting 35 Watt 230 V. |
| 83 | All as per serial item No. 79 here-in-before but LED street light fitting 45 Watt 230 V. |
| 84 | All as per serial item No. 79 here-in-before but LED street light fitting 60 Watt 230 V. |
| 85 | Supply and fixing in repair automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2.complete all as specified and as directed by Engineer-in-charge. |
| 86 | Supply and fixing in replacement street light panels analog time switch (with battery back up), 3P Module, 24 hours program, programmable every 15 min, current capacity 63 Amps, suitable for 63 Amps street light timer, AC 3 phase, 110-240 V AC (1CO) base/ Din 16 pulse digital time switch complete all as specified and as directed by Engineer-in-charge. |
| 87 | Supply and fixing in repair LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |