Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screw including necessary scaffolding, upto four storey building including Dismantling plain or corrugated steel sheeting, any gauge ,thickness including Nainital or similar pattern roof covering including necessary scaffolding, any type, any location/height complete all as specified and directed. |
| 2 | S & F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, upto four storey building including dismantling plain or corrugated steel sheeting, any gauge ,thickness including Nainital or similar pattern roof covering including necessary scaffolding, any type, any location/height complete all as specified and directed. |
| 3 | M & L second class soft wood in scantling clean swan below or above ground level upto four storey building, including dismantling timber scantling 40 Sqcm and over in section in any position in unframed work complete all as specified and directed. |
| 4 | All as per item No 3 above but except timber including Dismantling timber scantling 40 Sqcm and over in section in any position in unframed work complete all as specified and directed. |
| 5 | Dismantling wall and ceiling boards or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 6 | M&L plywood grade BWR type BB, 6mm thick fixed with nails to timber frame work in ceiling complete all as specified and directed. |
| 7 | M&L plywood grade BWR type BB, 6mm thick fixed with nails to timber frame work in lining complete all as specified and directed. |
| 8 | All as per item no 7 above but except plywood. |
| 9 | M&L for veneered decorative plywood, 6mm thick grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work as in ceiling complete all as specified and directed. |
| 10 | M&L for veneered decorative plywood, 6mm thick, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work as in walls complete all as specified and directed. |
| 11 | M & L for plain fillets 2nd class soft wood of exc. 3 & n exc. 6 Sqcm, square rectangular or triangular in section, clean swan, secured nails complete all as specified and directed. |
| 12 | M&L for Preparation of newly un treated surfaces and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and directed. |
| 13 | M&L for Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 14 | M&L for Preparation of old painted surfaces and applying two coat of synthetic enamel paint on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 15 | S&F sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane including Hacking out old broken glass (any thickness, size quality of description) from wooden frames or stone, concrete or brick sorrounds, glazad with putty or fixed with beads complete all as specified and as directed. |
| 16 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 including demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 17 | M&L for Random rubble masonry using sand stone uncoursed well bonded bedded and solidly hearted built in CM 1:4 including demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed. |
| 18 | All as per item no 17 above but except stone including Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 19 | M&L for cement concrete of type C-1, 1:3:6 (20mm graded aggregate) in coping, lintel bands, strings courses etc slightly rounded and chamferred angles and throating etc and setting in mortar complete with joints to match, complete all as specified and directed. |
| 20 | Taking down chowkat with shutters n. exc.1.5 Sqm (w/o taking off shutters from chowkhat) complete all as specified and directed. |
| 21 | Taking down chowkhat with shutter without taking off shutter from the frame exc 1.5 Sqm and not exc 4 Sqm each. |
| 22 | S & F 2nd class soft wood plain solid straight chowkats and frames wrought framed, rebated on the solid complete all as specified and directed. |
| 23 | S & F plain framed, panelled shutters 35mm thick 2nd class softwood, (any numbers of panels), with panels of timber flats on both sides, or of veneered particle board med density, wood particle board with commercial face or 9mm BWP plywood fitted to chowkat complete all as specified and directed. |
| 24 | S & F glazed & skeleton shutters 35mm thick 2nd class softwood, open rebated and prepared to receive glass, gauze, etc, edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I Section 8 clause 8.24 (a) fitted to chowkhats complete all as specified and directed. |
| 25 | S & F glazed & skeleton shutters 30mm thick 2nd class softwood, open rebated and prepared to receive glass, gauze, etc, edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I Section 8 clause 8.24 (b) fitted to chowkhats complete all as specified and directed. |
| 26 | S&F 100 mm long butt hinges extruded aluminium anodised complete all as specified and directed. |
| 27 | S&F 75 mm size mild steel butt hinges medium weight complete all as specified and directed. |
| 28 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 29 | S&F 75 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 30 | S&F aluminium anodised alloy handles fabricated type 150mm size of handle complete all as specified and directed. |
| 31 | S&F 100 mm long aluminium handles cast type anodised complete all as specified and directed. |
| 32 | S&F 300mm long aluminium alloy, anodised sliding door bolt, with hasp and staple (bolt type) cast or extruded section and fixing bolts of extruded section complete all as specified and directed. |
| 33 | S&F 300mm, MS ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 34 | S& F floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel pin fixed to door, over all length 140 mm complete all as specified and directed. |
| 35 | S & Fix in repairs Harrison rails/curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 36 | S & F in repair Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 37 | S & F in repair Vitreous China urinal, Half stall type, white with grating and union for discharge pipe including providing and fixing plugs with and including 60mm long brass screws, pointing around urinal back in cement with PVC 32mm dia waste pipe & waste coupling incl spreader complete all as specified. |
| 38 | S&F in repairs Vitreous China Wash down water closet pan (Pedestal pattern), white including plastic water closet seat and cover closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device & including P or S trap and connection to trap and to the flushing system anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 39 | S&F in repairs Vitreous China Ware Wash hand basin white flat back size 550mmx400mm including pedestal, cutting for and pinning ends of brackets or erecting stand including necessary PVC outlet pipe, CP coupling 32mm dia complete all as specified and directed. |
| 40 | S&F in repairs vitreous China squatting pan 'Orissa' pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing system anti syphonage pipe etc complete all as specified and as directed |
| 41 | S&F in repairs PVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr capacity white with flush pipe & all fitting complete all as specified. |
| 42 | S&F in repair Stop/Angle valves cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore pipe complete all as specified and directed. |
| 43 | S&F in repair Bib taps cast copper alloy, chromium plated, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule of 15mm bore, complete all as specified and directed. |
| 44 | S&F in repairs pillar tap cast copper alloy, fancy type with capstan heads chromium plated screwed down with high pressure with or without lettered hot or cold with long screwed, shanks and fly nuts screwed for iron pipe 15mm dia complete all as specified and as directed. |
| 45 | S&F in repairs 600 x 450mm size bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 46 | S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 47 | S&F in repairs Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 48 | S&F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 49 | S&F in repairs towel ring of brass chromium plated complete all as specified and as directed. |
| 50 | S&F 1000 Ltr capacity PVC water storage tank (cylindrical vertical with closed top) and fixed in position all as specified in SSR Part -I, including dismantling of old unserviceable tank complete all as specified and directed. |
| 51 | S&F in repair ball valves, high pressure, with polythene float and flynut complete, 20mm bore complete all as specified and directed. |
| 52 | S&F in repair 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends complete all as specified and directed. |
| 53 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 54 | S&F in repair Grating doom 100mm dia of PTMT (minimum weight 25gms) suitable for floor taps, all as specified and directed. |
| 55 | S&F in repairs health faucet (hand shower) chromium plated complete all as specified and as directed. |
| 56 | Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 deep for foundation for shafts, wells, cesspits, manholes etc not exc 10 sqm on plan and getting cut in soft/loose soil complete all as specified and directed. |
| 57 | M&L for PCC 1:4:8 type C-2 using 40 mm graded stone aggregate for foundations, filling and mass concrete complete all as specified and directed. |
| 58 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate for bedding and coping and casting of post including necessary form work complete all as specified and directed. |
| 59 | Returning filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed |
| 60 | Removal of excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 61 | S&F mild steel round or square bars Confirming to F-410 W (Gde E-250)Quality A work in rungs, hooks, handles, for drain covers, hold fast & small articles complete all as specified and directed. |
| 62 | Demolition cement concrete (un reinforcement) in ground floor and paving n exc 15 cm thickness (below or above ground level) & removal complete all rubbish materials complete all as specified and directed. |
| 63 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete, using extra cement including forms/moulds/mitred stopped ends etc complete all as specified and directed. |
| 64 | M&L for cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed. |
| 65 | Demolition of RCC of any description and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 66 | M&L for precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in manhole cover slabs, of any thickness, size or shape including necessary form work, set and jointed in cement mortar (1:4) complete all as specified and directed. |
| 67 | M & L for Mild steel bars 10mm dia and over, Fe-410-W (Gde.E-250) Part- I quality-A or Fe 290 (Gde - E-165) cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 68 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortal 1:6 including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars & precast concrete masonry etc complete all as specified & directed. |
| 69 | M&L for preparation of previously treated surfaces/old surface of wall and applying one coat cement base paint on old surface of wall complete all as specified and directed. |
| 70 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 71 | M&L 15mm thick cement plaster on external surface in CM 1:4 mixed with WPC 3% by weight of cement including finishing fair & even including Taking down cement or cement lime plaster, of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 72 | S&F water proofing compound as per IS-2645 complete all as specified and directed. |
| 73 | M&L for 15mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 74 | S&F for 75mm to 90 mm thick Steel Fibre Reinforced (SFRC) cover with iron frames (Light duty) complying to the standard specifications as mentioned in the IS 12592 BIS standard, minimum load bearing capacity 2.5 ton, in square, rectangular or circular shape complete all as specified and directed. |
| 75 | M&L for providing and fixing in repair concertina coil fencing with punched tape concertina coil 600 mm dia 10m openable length (total length 90m) having 50 nos rounds per 6 m length, up to 3.0m height of wall with existing angle iron Y shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tired with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of engineer in charge, with reinforced barbed wire tape (R.B.T)/spring core (2.5 mm thick) wire of high tensile strength of 165kg/sq.mm with tape (0.52 mm thick 0 and weight 43.478 gm/metre (cost of M.S. angle, CC Blocks shall be paid separately). |
| 76 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. and in any mortar complete all as specified and directed. |
| 77 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed. |
| 78 | M&L for 20 cm x 20cm size and 25 mm thick chequered cement concrete tiles (in any colour & shape), set, jointed and pointed in neat cement slurry in floors with grey cement & no pigment over 20 mm screed bed in CM 1:6 complete all as specified & directed. |
| 79 | M&L for 75mm thick plain cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 80 | M&L for sand filling under floors or in foundations including watering and consolidation all as specified and as directed |
| 81 | M&L for hardcore of gauge (broken bricks) n exc 63mm deposited spread levelled in layers n exc 15 cm thick watered and rammed to a true surface with gauze broken boulder exc 90 cm complete all as specified and directed. |
| 82 | M & L cement concrete type B-1 1:2:4 (20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed copings, packing around interlocking paver and fixing of Y angle section complete all as specified and directed. |
| 83 | Dismantling structural steel work including doors gates etc complete all as specified and directed. |
| 84 | Excavation in post hole each n. exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces in soft/loose soil complete all as specified and directed. |
| 85 | M&L for PCC (1:3:6) type C-2 as in foundation filling and mass concrete for MS angle posts all as specified |
| 86 | Dismantling fencing wire mass any type complete all as specified and directed. |
| 87 | S&F mild steel work angle iron fixed independently without connecting plates complete as in fencing post or struts/ 'Y' section including cutting shape as directed, drilling holes, welding notching wire including embedding in concrete and screwing conforming to Fe-290 Gde E-165 etc complete all as specified and directed. |
| 88 | Fixing Only chain Link Fencing Including Line wire any Mesh Size and type to any type of standard rails straining bolts etc including provision of binding wire complete all as specified and directed. |
| 89 | S&F Chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 90 | Dismantling of old barbed wire etc complete all as specified and directed. |
| 91 | S&F in repairs GI 2 standard steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of stranded rails, straining bolts including securing or tying at crossing with and provision of galvanised MS wire, staples or steel pins etc complete all as specified and directed. Note:-Each line of wire to be measured. |
| 92 | M&L for mild steel bars 10mm dia round and plain bars and over cut to length bent to shape required including cranking bending for Support of Chain Link fencing including nut and bolt Fe-410-W) (Gde.E-250) Part- I quality-A complete all as specified and directed. |
| 93 | M&L for mild framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including ornamental and intricate design and portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed. |
| 94 | S&F for preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 95 | M&L RCC work M-25 design mix (using 20mm graded crushed stone aggregate) as in slab supported in walls cantilevers etc complete all as specified and directed. |
| 96 | M&L for form work as in suspended slab, such as roof slabs, floor slabs, landings and similar work, not exceeding 20mm thick (Horizonal or sloping) complete all as specified and directed. |
| 97 | Supply and lay in trenches with replacement of UG cable of any size Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete with taking down all as specified and directed of size 16 sqmm 2.0 core |
| 98 | All as per item No 97 00 above but cable of size 25 sqmm 3.5 core |
| 99 | All as per item No 97 00 above but cable of size 35 sqmm 3.5 core |
| 100 | All as per item No 97 00 above but cable of size 50 sqmm 3.5 core |
| 101 | All as per item No 97 00 above but cable of size 70 Sqmm 3.5 core |
| 102 | All as per item No 56.00 above but depth exc 1.50 but n.exc 3.0m deep. |
| 103 | Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed. Note:- Punned thickness only shall be measured and paid. |
| 104 | Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed. |
| 105 | Supplying and fixing, light grade, Galvanised mild steel pipe / tubing, complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection for size 40 mm bore:-. (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):- |
| 106 | All as per item No 105.00 above but 50 mm bore pipe. |
| 107 | M&L for rest retching of LT /HT ACSR conductor and GI wire of any size and on any type of poles carrying up to six conductors in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles complete all as specified and directed. |
| 108 | M&L for Cutting /Trimming/ Chopping of tree branches along the overhead lines upto 3 m from elect lines clearance on both sides of HT/LT lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site complete all as specified and directed. |
| 109 | Material and labour of repair unserviceable LED Street Light/ Security Light of 25 to75 Watts, including replacement of driver with a new driver (having surge protector and lightning protector) with input Voltage variation between 140V to 300V (voltage in this region will not be considered as surge voltage), with complete all as specified and directed. |
| 110 | S&F of suitable LED driver (having surge protector and lightning protector) with input Voltage variation between 140V to 300V (voltage in this region will not be considered as surge voltage) for LED Street/ security Lights upto 25 to 75 Watts, with warranty of two years. |
| 111 | M&L in replacement of ACSR conductor of any size and any type including stretching, fixing and binding to insulator on OH LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified. This item includes all consumables (such as binding wire and replacement insulators and cross arms, etc., for replacement of damaged ones found after/ during replacement process). |
| 112 | S&F of MCCB 63-100 Amp 3/4 Pole (As per site Requirement) 415 Volt breaking capacity 16kA complete all as specified and directed. |
| 113 | S&F of MCCB 125 Amp 4 Pole 415 Volt breaking capacity 16kA complete all as specified and directed. |
| 114 | S&F of MCCB 200 Amp 4 Pole 415 Volt breaking capacity 25kA complete all as specified and directed. |
| 115 | S&F of MCCB 250 Amp 4 Pole 415 Volt breaking capacity 36kA complete all as specified and directed. |
| 116 | S&F of MCCB 400 Amp 4 Pole 415 Volt breaking capacity 36kA complete all as specified and directed. |
| 117 | Supply and fixing of 125 AMP busbar chamber (wall mounted) Busbar made of ETP Grade copper 6 way all as specified and directed. |
| 118 | Supply and fixing of 200 AMP busbar chamber (wall mounted) Busbar made of ETP Grade copper 6 way all as specified and directed. |
| 119 | S&F of on load changeover switch 415 volt in sheet metal enclosure 4 pole of capacity 100Amp (as required) complete all as specified and directed. |
| 120 | S&F of on load changeover switch 415 volt in sheet metal enclosure 4 pole of capacity 160 Amp (as required) complete all as specified and directed. |
| 121 | S&F of off load changeover switch with handle 415 volt in sheet metal enclosure 4 pole of capacity 200 Amp (as required) complete all as specified and directed. |
| 122 | S&F of off load changeover switch with handle 415 volt in sheet metal enclosure 4 pole of capacity 320 Amp (as required) complete all as specified and directed. |
| 123 | M&L for Painting to LT poles, 9 mtr with cross arms, bracing and clamps with one coat of synthetic enamelled paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30 cm height all as specified and directed. |
| 124 | S&F in replacement mild steel cross arms, bracing, supports clamps and back plates, fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including one primer, one under coat and one finishing coat of aluminium paint over prepared steel surface complete all as specified and directed. |
| 125 | M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified and directed. |
| 126 | M&L in replacement of Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade all as specified. |
| 127 | S&F self Adhesive electrical insulation tape of size 2.5cm x 25m x 0.125mm, ISI marked complete all as specified and directed. |
| 128 | Supply ,erecting and fixing the true vertical position, steel tubular swaged pole(410 SP-31),09 mtr long, complete with cast iron base plate, pole cap/final taper plug ,bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole ,including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.(Numbering of the poles shall be done with synthetic enamelled painted letter of shape & size complete all as specified and directed. Note:- (a) Cost of numbering of pole shall be deemed to be included in unit rate. (b) Excavation, Earth work and PCC foundation will be measured and paid for separately. |
| 129 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts as specified including necessary form work, complete all as specified & directed. |
| 130 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly etc including necessary form work, complete all as specified & directed. |
| 131 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified & directed. |
| 132 | S&F 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm nominal cross section in service connections complete all as specified and directed |
| 133 | S&F 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections complete all as specified and directed |
| 134 | S&F LT PVC line separator for outdoor for pole 4 wire complete all as specified and directed. |
| 135 | S&F LT PVC line separator for outdoor for pole 3 wire complete all as specified and directed. |
| 136 | M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion with earth work complete all as specified and directed. |
| 137 | Supply and connecting 1100 volts grade heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed of size 2.5/4 sqmm 3 core for pole box to street light fitting complete all as specified and directed. |
| 138 | S & F GI bracket made out of GI pipe light grade of size 40/32 mm 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers complete all as specified and directed. |
| 139 | Supply and fix street light Engineering plastic one piece moulding control box with locking arrangement made out of HDPE and FI clamp 25 x 3mm complete of dimensions in CM +/-10%(34x28x13) including MCB SP 6 Amp 240 Volts complete with 02 Nos aluminium busbar or terminal two Nos (2P-R/Y/B and N) of rating 63 amps for single phase and neutral on porcelain based insulators complete all as specified and directed. |
| 140 | Supply and fix in replacement LED flood/ focus light 60 W made up of pressure die cast aluminium housing toughened glass and high power LEDs and secondary lenses with IP 66 protection. Option for 3000k. 10 KV SPD included complete all as specified and directed. |
| 141 | Supply and fixing of LED motion sensor street light fitting 50 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 142 | Supply and fixing LED street light luminaries 60 Watt having shall be made of single piece Aluminium Die cast with powder coated in RAL-7032 shade with heat distribution fins on housing with UV stabilized toughed glass cover and should have secondary lens on each LED for better light distribution. The system luminaire efficacy should be > 110 LM/W with high power LED. LED driver should be potted and BIS certified with efficiency > 85 % frequency 50 HZ, Operating voltage range 120V-270V,current not more than 0.320 Amp, PF 0.95, THD (I) < 10 %, supported with 5 KV internal and 10 KV external SPD, Humidity 10% to 90 % RH, working temperature - 20⁰ C to 50⁰ C lige expectancy of LED should be 50000 burning hours with minimum 70 % initial lumen maintained, CRI >70 |
| 143 | Supply and fixing in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail