| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8110/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIRS AND DAY TO DAY MAINTENANCE TILES, NAHANI TRAPS, SUNKEN FLOOR, MASONRY, PLASTERING, CRACK FILLINGS, SWR PIPES AND OTHER MISC B/R WORKS OF OTM/MD ACCN BLDGS AT MH/MD AREA OF AGE B/R-II UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Taking down cement or cement lime plaster on brick wall / stone walls/concrete surfaces, ceilings etc. including ranking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 3 | M&L for Rendering, 15mm thick , in CM (1:4) mixed with water proofing compound as per manufacturer instruction on fair surfaces of brick or concrete walls, finished even and smooth without using extra cement all as specified and as directed.Note: WPC shall be measured and paid separately. |
| 4 | Supply only liquid water proofing compound of approved make complete all as specified and as directed. |
| 5 | M&L for 15mm thick plastering in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 6 | M&L for 5 mm thick plastering in CM 1:3 finished even and smooth w/o using extra cement on brick or concrete surface of ceilings complete all as specified and as directed. |
| 7 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali-resistant primer and 1.5 mm thick wall care putty on plastered surfaces complete all as specified and as directed. |
| 8 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali-resistant primer and 1.5 mm thick wall care putty on plastered surfaces complete all as specified and as directed. |
| 9 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on wall surfaces complete all as specified and as directed. |
| 10 | M&L for preparation of newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new wall surfaces complete all as specified and as directed. |
| 11 | Complete removal of existing treatment to wall and apply two coats of Oil bound distemper over one coat of alkali-resistant primer and 1.5 mm thick wall care putty including preparation of surface complete all as specified and as directed. |
| 12 | M & L for preparation of old decorated surfaces of walls plastered or unplastered including removing by brooming down all dust, dirt and all loose scales by steel wire brushing, scrapping down smoke, soots, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of Oil bound distemper to walls, white or tinted complete all as specified and as directed. |
| 13 | M & L for preparation of old decorated surfaces of ceiling plastered or unplastered including removing by brooming down all dust, dirt and all loose scales by steel wire brushing, scrapping down smoke, soots, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of Oil bound distemper on ceilings, white or tinted complete all as specified and as directed. |
| 14 | M&L for preparation of old painted surface of wood and wood based materials of any description not otherwise described over 10 cm. width or girth shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of synthetic enamel painting complete all as specified and as directed. |
| 15 | M&L for preparation of old painted surface of Steel and iron work of any description not otherwise described over 10 cm. width or girth shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 16 | M&L for preparation of old surfaces of plaster or concrete work of any description not otherwise described over 10 cm. width or girth by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 17 | M & L for complete removal of existing treatment (by high pressure water jet) and applying two coats of cement based paint on prepared surfaces of walls complete all as specified and as directed. |
| 18 | Material and labour for preparation of old decorated chequered tile, concrete or plastered surfaces applying two coats of terra cotta complete all as specified and as directed. |
| 19 | M&L for in repair cement concrete 1:2:4 Type B0 (12.5mm graded stone aggregate) beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level |
| 20 | M&L for formwork to small surfaces such as cantilever ends, brackets, ends of steps, caps and bases of pilasters and the columns and the like finishing to fair finished surface of concrete complete all as specified and as directed. |
| 21 | M&L for cleaning/removing all vegetation, bushes/small trees on wall and making good the surfaces with PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) or rendering in CM (1:3) including removing spoils obtained to a distance not exc 50 metre and depositing complete all as specified and as directed. |
| 22 | Cutting & trimming of tree branches any girth and size touching to sewage lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 40 mtrs each and removing the same cleaning the site all as specified and as directed. |
| 23 | Demolition of cement concrete (Un-reinforced) in roof n exc. 15cm thick including removing of existing felt and removal of debris complete all as specified and as directed |
| 24 | M&L for cement concrete 1:2:4 type B0 (using 12.50mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges mixed with water proofing compound at 200ml per bag of cement and self curing admixtures to prevent leakages and seepages, finishing the surface even and smooth without using extra cement complete all as specified and as directed |
| 25 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate and WPC) as in roof padding followed by 14 days water curing with ponding complete all as specified and as directed. |
| 26 | Cutting out V - grooves in plaster / masonry / concrete and inserting the waterproofing membrane and making good in CM 1:3 complete all as specified and as directed. |
| 27 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bituminous primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminium paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including rendering 10mm thick in cm 1:4 on concrete surfaces of roofs, parapet etc. finishing to surfaces even and smooth without using extra cement and providing necessary slope with using WPC @ 3% by weight of cement complete including taking down existing roof treatment and cement plaster of any description, roughing, preparing the surface by cleaning the surface with wire brushing scrubbing down with water to receive new treatment complete all as specified and as directed. (NOTE : Supply of WPC will be paid under the respective Item) |
| 28 | Supply only integral water proofing compound. |
| 29 | Demolition of cement concrete (unreinforced) on sunken floor, roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work |
| 30 | M&L for sunken floor filling with cement concrete Type E2 1:5:10 (Using 40 mm graded stone aggregate) complete all as specified and as directed. |
| 31 | M&L for in sunken floor with 15mm thick rendering in cement mortar 1:3 with WPC on fair faces of brick or concrete surface,etc complete all as specified and as directed. (WPC will be paid separately) |
| 32 | M&L for in sunken floor with APP modified pre-fabricated five layer water proofing membrane 3 mm thick not less than 3.60 kg/sqm applied and laid over primed surface including bituminous primer conforming to IS -3384 as per manufacturer instruction complete all as specified and as directed. |
| 33 | Disconnecting existing tanks of any capacity 500 or 1000 or 2000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after laying of WPT etc. complete all as specified and as directed. |
| 34 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity of tank 500 ltrs complete all as specified and as directed. |
| 35 | Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity of tank 1000 ltrs complete all as specified and as directed. |
| 36 | M&L for writing letters or figures (Block, Roman, Italic,or Indian) over PVC/RCC water tank (each letter per cm of width and 6 cm of height) complete all as specified and as directed. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish of the premises complete all as specified and as directed. |
| 38 | M&L for Vitrified light shade ceramic tiles 10 mm thick (square/ rectangular ) polished, area of each tile not exceeding 0.36 sqm , in floor/wall etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:6),complete all as specified and as directed. |
| 39 | M&L for Vitrified light shade ceramic tiles 10 mm thick (square/ rectangular ) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm , in floor/wall etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:3),complete all as specified and as directed. |
| 40 | M&L for non skid coloured ceramic floor tiles 7-8 mm thick (square/ rectangular ) area of each tile exc 0.11 sqm but n.exc 0.18 sqm , set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:6),complete all as specified and as directed. . |
| 41 | M&L for non skid coloured ceramic tiles 7-8 mm thick (square/ rectangular ) area of each tile exc 0.06 sqm but n.exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:6),complete all as specified and as directed. |
| 42 | M&L for glazed ceramic coloured tiles 450 x 300 x 7 mm / 350 x 250 x 7mm in vertical surface fixed over and including 10mm thick back coat in CM 1:4, set and jointed in cement slurry and pointed with white or coloured cement to match complete all as specified and as directed. |
| 43 | M&L for chequered cement concrete coloured tiles, textured finished of size 250 x 250 x 22 mm/ 300 x 300 x 22 mm thick set jointed in neat cement slurry and pointed with white cement and pigment in floors to match with colour of tiles, over 15mm thick screed bed in CM (1:6) including dismantling of existing tiles complete all as specified and as directed. |
| 44 | Demolition of stone slab and tiles of any description or thickness in floors, aprons laid , bedded and pointed any mortar complete all as specified and as directed. |
| 45 | M & L for Granite (of any type) work (table rubbed and polished) 20 mm thick in steps, jambs, pillars, window-cills, cooking platforms, over 20 mm thick screed bed in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc complete all specified and directed. |
| 46 | M&L for 20-25mm thick machine cut kota stone slab flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over 20mm thick screed bed in CM 1:4 including grinding, rubbing and mirror polishing to achieve a high-gloss smooth surface finish complete all as specified and as directed. |
| 47 | M & L for 20-25 mm thick machine cut kota stone slab over 15 mm thick rendering in cement mortar 1:3 as in backing coat in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and as directed. |
| 48 | S&F in repairs sinks with drainage board made of stainless steel 1 mm thick, kitchen sink with plugs, washers and wastes; including bedding in cement mortar on dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 49 | S&F for 110 mm PVC (SWR) pipes single socket length fixed as spouts on roof including cutting holes in brickwork/stone masonry/concrete surface and making good with rich cement mortar and sealed with bitumen complete all as specified and as directed. |
| 50 | Excavation in trenches n.exc 1.50m wide and n.exc. 1.50 m depth and getting out in hard/dense soil complete all as specified and directed. |
| 51 | M & L for Plain cement concrete (1:3:6) type C2 (40mm graded stone aggregate) as concrete bed to drain pipes of any dia including packing under, and haunching against the sides of pipes after they are laid and tested including demolition of existing concrete bed, haunching and pipe, complete all as specified and as directed. |
| 52 | S & F in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors / fixed to walls, bore of pipe in 110 mm, etc complete all as specified and as directed. |
| 53 | S & F in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors / fixed to walls, bore of pipe in 75 mm, etc complete all as specified and as directed. |
| 54 | S & F in repair PVC (SWR) bends any radius 110 mm dia, complete all as specified and as directed. |
| 55 | S & F in repair PVC (SWR) bends any radius 75 mm dia, complete all as specified and as directed. |
| 56 | S & F in repair PVC (SWR) branch piece, single (single Y) equal or unequal any radius, 110 mm dia, complete all as specified and as directed. |
| 57 | S & F in repair PVC (SWR) junction single, (Single T) equal or unequal any radius, 110 mm dia, complete all as specified and as directed. |
| 58 | S & F in repair PVC (SWR) vent cowl 110 mm dia, complete all as specified and as directed. |
| 59 | M&L for in repair 110 mm bore PVC( SWR ) bend with oval access doors complete all as specified and directed. |
| 60 | M&L for in repair 75 mm bore PVC( SWR ) bend with oval access doors complete all as specified and as directed. |
| 61 | M&L for in repair 75 mm PVC Nahani/ floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 62 | S & F in repairs Vitreous China wash basin, white, flat back, size 630x450mm including cutting for & pinning in ends of brackets or erecting stand but exclusive of fixing of supply of waste pipe complete all as specified and as directed. |
| 63 | S & F in repairs Vitreous table top wash basin, white, rectangular with curved corners of size 400x500mm including cutting and setting on granite including waste fitting but excluding the waste pipe etc complete all as specified and as directed. |
| 64 | S & F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 65 | Careful dismantling and Re-fixing the EWC using high-grade white cement mixed with waterproofing compound or anti-fungal silicone sealant at the base to ensure a water-tight joint after removing the old sealant/white cement at the base and replacement of the rubber gasket/wax ring/seal between the WC outlet and the soil pipe etc complete all as specified and directed |
| 66 | S & F in repairs Vitreous china premium/ 1st quality wash down water closet EWC square pattern including all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect complete all as specified and as directed. |
| 67 | S & F in repair plastic water closet seat , black/white, closed pattern with flat bottom & cover and mild steel chromium plated or aluminized hinging device complete all as specified and as directed. |
| 68 | Supply and fix in repairs PVC valve less symphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe complete all as specified and as directed. |
| 69 | S&F in repair Vitreous China soap dish approximate size 160x 160x90mm embedded in the wall complete all as specified and as directed. |
| 70 | M&L for Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 10 cm but not exc 20cm girth complete all as specified and as directed. |
| 71 | S&F in repair for 15mm bore of length exceeding 1m, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor. complete all as specified and directed |
| 72 | S&F in repair for 15mm bore fitting for medium grade, galvanised iron pipe (with or without replacing of pipe in short lengths upto 1m length), medium grade, galvanised iron pipe, complete all as specified and directed |
| 73 | S&F in repair of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 74 | S&F in repair of 25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 75 | S & F in repair Brass Elbow for CPVC pipe of outer 20mm, complete all as specified and as directed. |
| 76 | S & F in repair Brass Elbow (3/4 X ½) for CPVC pipe of outer 20mm, complete all as specified and as directed. |
| 77 | S & F in repair Brass Tee for CPVC pipe of outer 20mm, complete all as specified and as directed. |
| 78 | S & F in repair Male Brass Threaded Adaptor (MTA/ MBTA) for CPVC pipe of outer 20mm, complete all as specified and as directed. |
| 79 | S & F in repair Female Brass Threaded Adaptor (FTA/ FBTA) for CPVC pipe of outer 20mm, complete all as specified and as directed. |
| 80 | Demolition of cement concrete in ground floor or paving of any description n.exc. 15cm thickness (Un re-inforced) below or above GL complete all as specified and as directed. |
| 81 | M & L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 82 | M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) set in CM 1:4 as in benching to manholes / gully traps etc complete all as specified and as directed. |
| 83 | M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in copping including necessary form work all as specified. |
| 84 | Demolition of brick work or stone masonry, built in cement mortar complete all as specified and as directed. |
| 85 | M & L for brick work with fly ash bricks built in CM 1:6 with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius all as specified. |
| 86 | M & L for half Brick wall with old size fly ash bricks straight or curved on plan to any radius built in cement mortar 1:6 complete all as specified and as directed. |
| 87 | M&L for cement concrete 1:2:4 type BI using 20mm graded stone aggregate in bed block for hold fasts and coping including necessary form work weathering slightly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and as directed. |
| 88 | Demolition of Concrete of any description and in any position not otherwise specifically provided for, cement concrete (reinforced), etc complete all as specified and directed. |
| 89 | M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate as in pre-cast cover slabs for manholes covers, shelves etc including necessary form work set in CM 1:4 all as specified. (Reinforcement will be measured & paid separately) complete all as specified and as directed. |
| 90 | M&L for Mild Steel TMT Bars 6 to 8mm dia bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engr-in-Charge. |
| 91 | M & L for 75 mm thick PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) in sub bases, floors and pavings etc., |
| 92 | M & L for 25 mm thick PCC 1:2:4 Type B0 (using 12.5 mm graded stone aggregate) in sub bases, floors and pavings etc., |
| 93 | S & F Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts of size 25x3MM MS flat; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed. |
| 94 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection including expansion or contractions joints at specified intervals, finished even and smooth w/o using extra cement complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |