| 1 | Demolition of brick work in cement mortar incl all quions, arches,pillars etc, but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified & directed. |
| 2 | M&L old size brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM 1:4 complete all as specified & directed. |
| 3 | All as per above item but except bricks. |
| 4 | Demolition of RCC of any description and any position not othervise provided for complete all as specified & directed. |
| 5 | M&L RCC(1:2:4) type B1 using 20 mm graded stone aggregate in beams, coping, etc and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified & directed. |
| 6 | Formwork to sides and soffits of rough finished surfaces of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified & directed. |
| 7 | M&L TMT bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with MS steel wire (annealed) not less than 0.90 mm dia complete all as specified & directed. |
| 8 | M/L mild steel TMT bars 8mm dia cut to length bent to shape required and binding with ms wire anealed not less than 0.9mm dia, complete all as specified & directed. |
| 9 | Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. complete all as specified & directed. |
| 10 | M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) on wall finishing the surfaces even and fair without using extra cement complete all as specified & directed. |
| 11 | M & L for rendering 15 mm thick on other than fair faces of bricks/concrete surface in cement mortar (1:4) on wall finishing the surfaces even and fair without using extra cement complete all as specified & directed. |
| 12 | M&L for preparation of newly plastered surface and applying two coat of Acrylic Smooth exterior paint of required shade/camouflage over and including priming coat of exterior primer complete all as per manufacturer instruction & directed. |
| 13 | M&L for preparation of old wall surfaces and applying one coat of Acrylic Smooth exterior paint of required shade/camouflage complete all as per manufacturer instruction & directed. |
| 14 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion complete all as specified & directed. |
| 15 | S/F MS steel post struts fencing post including cutting top to shape,drilling holes notching for wire etc including all necessary drilling bolting and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. |
| 16 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified & directed. |
| 17 | M &L for preparation of new steel surfaces and applying two coats of black bituminious paint exceeding 10cm in width or girth complete all as specified & directed. |
| 18 | S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc complete all as specified & directed. Note : Each line wire to be measured. |
| 19 | Fixing only in repair of galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts complete all as specified & directed.Note : Each line wire to be measured. |
| 20 | Dismantling fencing wiremesh any type |
| 21 | Supply only chain link MS galvanised fencing, any size or type complete all as specified & directed. |
| 22 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standrad , rails, straining bolts, etc. including provision of binding wire complete all as specified & directed. |
| 23 | S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified & directed. |
| 24 | S&F in repair precast cement concrete type B0 1:2:4 using 12.5 graded sotne aggregate set in CM (1:4) as louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified & directed. |
| 25 | Demolition of Concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) |
| 26 | M&L for providing cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate in foundations,filling and mass concrete, filling of post holes, etc complete all as specified & directed. |
| 27 | M&L for providing cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, bed plates including weathering, slightly rounded or chamfered angles andthroating, complete all as specified & directed. |
| 28 | M&L for one coat of synthetic enamel paint on old steel surfaces of steel over 10cm in width or girth not otherwise described complete all as specified & directed. |
| 29 | S&F Concertina coil 600 mm Dia/56 Loops/2.5 mm core wire. Coil Diameter:600 mm. Type of Strip: Heavy Galvanized (IS 1730) Type of Core Wire: Heavy Galvanized (IS 280-2006) Core wire Diameter:2.50mm Dia Zinc coating to Strip: Minimum 200 GSM/Sq mm, Zine Coating on wire: Minimum 275 GSM/Sq mm (IS 6745-1972 reaffirmed 2006). Tensile Strength of wire 1400-1500 N/Sq mm Weight: 14.63 Kg (+5%) Number of Loops: 56 Blade Length: 22mm Barb Profile Medium Blade (MBBT) Distance Between Barb 35mm. Strechable length 12 mtrs. Type of clip Hardened Steelin Galvanized steel (83 Nos coil per Km) complete all as specified & directed. Please Enable Macros to View BoQ information |