| 1 | Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15cm thickness (below or above the ground level) complete all as specified and directed |
| 2 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as sub base finished even & fair complete all as specified and as directed |
| 3 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 4 | M&L pre-polished coloured chemically treated, smooth finish exterior grade chequered tiles of size 300 mm x 300 mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed or bedding layer in cement mortar (1:6) as in path complete all as specified and as directed. |
| 5 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 6 | Dismantling post or struts (Wood steel or RCC) any size and shape including taking out embedded portion in concrete, brick work and making good disturbed ground complete all as specified and as directed. |
| 7 | Dismantling of fencing wire mesh of any description complete all as specified and as directed |
| 8 | Dismantling of barbed wire of any size and shape in any position complete all as specified and as directed. |
| 9 | Excavation in post holes in any type of soil each n.exc 0.5 cum, getting out to accommodate Steel fencing post by trimming/excavation complete and removing surplus soil to a distance not exceeding 50Mtr spread and leveled complete all as specified and as directed. |
| 10 | M&L cement concrete type C-2 1:3:6, 40mm graded aggregate as in foundation, filling in & mass concrete complete all as specified and as directed. |
| 11 | M&L providing plain cement concrete type B0 1:2:4 with using 12.5mm graded stone aggregates in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 12 | S&F galvanized. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and galvanized coating of steel wire shall confirm to the requirement as laid down for medium coated wire in IS 4826 and straining and fixing to any type of standard rails staining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc complete all as specified and as directed.(Each line wire to be measured). |
| 13 | Restraining and re securing including making good staples of old serviceable barbed wire in position complete all as specified and directed. |
| 14 | Supply only galvanised steel wire, (Hot dipped galvanised), 75 mm x 75 mm mesh, made up into mattresses or cages complete all as specified and as directed. |
| 15 | Fixing only chain link fencing to post old and new including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 16 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290-Gde E-165 complete all as specified and as directed. |
| 17 | S&F mild steel conforming to Fe.290.Gde-E-165 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including dismantling the unserviceable framed work complete all as specified and as directed. |
| 18 | M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but (dia of neck 10mm and 10cm long) complete all as specified and as directed. |
| 19 | M&L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enameled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified and as directed. |
| 20 | M&L for preparation of new steel and iron surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 21 | Demolition of brick work built in cement mortar of any description,etc complete all as specified and as directed. |
| 22 | M&L brickwork with fly ash bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and as directed. |
| 23 | M&L brick work with fly ash' bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed. |
| 24 | M&L for providing precast cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings and set in cement mortar 1:4 complete all as specified and as directed. |
| 25 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 26 | M&L for rendering 15mm thick cement plaster on other than fair surfaces of brick/concrete in cement mortar (1:6) finished even & smooth without using extra cement complete all as specified and as directed. |
| 27 | M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers first layer of 10 mm thick and top layer of 5 mm thick plaster with & including water proofing compound as per manufacturer's instructions finishing the surface even & smooth without using extra cement complete all as specified and as directed. |
| 28 | S&F preparation of newly plastered or concrete surfaces of any description and applying 3 coats of white washing complete all as specified and as directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and as directed. |
| 30 | M&L non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor over and including cement screed bed / backing layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.Note:- Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 31 | Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and as directed. |
| 32 | M&L for RCC type B1 (1:2:4) using 20 mm graded stone aggregate in fins, fascias, louvers, parapets, and railings, newels, balustrade & the like complete all as specified and as directed.Note: Reinforcement shall be measured and paid separatly under relevant item of this schedule. |
| 33 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 34 | M&L for TMT bars 10 mm dia ,cut to length bent to shape required in hooking ends fixed in chain link fencing complete all as specified and as directed. |
| 35 | M&L Reinforced concrete Pipes 600mm dia, class NP2 laid & jointed complete with collers complete all as specified and as directed. |
| 36 | M&L Reinforced concrete Pipes 450mm dia, class NP2 laid & jointed complete with collers complete all as specified and as directed. |
| 37 | M&L preparation of old steel and iron surfaces of any description not otherwise described, over 10 Cm width or girth and applying one coat of synthetic enamel paint 1st quality complete all as specified and as directed. Please Enable Macros to View BoQ information |