Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #55809294

Tender For Provn Of Store Room At 9 Rajput And Special Repair To Bldg No P-2 At 274 At Tezu Under Ge (P) Lohitpur

Issued by Statutory Bodies & Commissions/Committees · Lohit, Arunachal Pradesh
Tender Value
31 Lakhs
Estimated cost
Bid Submission
06 Jul 2026
5 days left
EMD
62000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lohit → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Store Room At 9 Rajput And Special Repair To Bldg No P-2 At 274 At Tezu Under Ge (P) Lohitpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Jun-2026 Critical Date Date 06-Jul-2026
2 15-Jun-2026 REVISED BOQ BOQ 06-Jul-2026
3 15-Jun-2026 REVISED BOQ BOQ 25-Jun-2026

BOQ

Name of Work:- PROVN OF STORE ROOM AT 9 RAJPUT AND SPECIAL REPAIR TO BLDG NO P-2 AT 274 AT TEZU UNDER GE (P) LOHITPUR
Sl. No. Item Description
1Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt or any treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 1000 m.all as directed
2Hacking out old broken glass(any thickness, size, quality or description) from wooden/steel frames, glazed with putty or fixed with beads complete all as specified and as directed.
3S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 Sq m in each pane upto three storey of bldgs complete all as specified and as directed.
4Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
5Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
6Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. but cement or cement lime plaster,any description
7S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any clour having yeild strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
8M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 20 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
9M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
10M & L for 15 mm thick cement plaster in two layer (10mm + 5mm) external coat mixed with WPC on fair faces of bricks/ concrete surfaces in cement mortar 1:4 including plastered surfaces shall be finished even & fair all as specified and as directed by Engineer-in-ChangeNote :- WPC will be measured separately.
11M & L for 15 mm thick cement plaster in two layer (10mm + 5mm) external coat mixed with WPC on fair faces of bricks/ concrete surfaces in cement mortar 1:3 including plastered surfaces shall be finished even & fair all as specified and as directed by Engineer-in-ChangeNote :- WPC will be measured separately.
12Supply only integral liquid water proofing compound complete all as specified and directed complete all as specified and directed.
13M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in floor/plinth protection , finish even & smooth without using extra cement all as specified and directed.
14M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing (Grade A )Compound complete all as specified and directed.
15M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed.
16M&L for preparing the old plastered surfaces and applying one coat of old decorateed surface and two coats of subsequent coat of white wash on walls all as specified and direcrted.
17M&L for preparing the old plastered surfaces of celling and applying one coat of undecorated surface and two coats subsequent coat white wash on celling complete all as specified and directed.
18M&L for preparing the new plastered surfaces on wall and applying two coats of cement base paint on a walls complete all as specified and directed.
19M&L for preparing the old plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed.
20M &L for Non asbestos fibrecement buildingboards 4 mm thick of size 600mm x 600mm fixed orlaid/ inserted to timber/ GI/ Aluminium frameworkwith screwcomplete all as specified and directed.
21S&f Anodised aluminium snap grid frame work for false ceiling all as specified Size of grid 605 x 605mm for celling with Gl frame work for seamless ceiling comprising of G l perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners wit mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
22M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.6 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
23M&L for 40mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in slab flooring bedded, and jointed in cement mortar CM 1:6 and pointed in cm 1:3 finish even & smooth without using extra cement all as specified and directed.
24M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in slab flooring finish even & smooth without using extra cement all as specified and directed.
25Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
26M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
27Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting out (upto 3.00 M beyond outer face of external wall) complete all as specified and directed.
28Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc n exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed.
29M& L Cement concrete 1:4:8 Type D 2 (using 40 mm graded aggregate, in foundations, filling and mass concrete complete all as specified and directed.
30Material and labour for reinforced cement concrete design mix M-25 (using 20 mm graded aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
31M & L for treating the bottom and sides of excavation at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed.
32M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed (Area of the sub structure in contact with backfill to be measured).
33Returning ,filling in including spreading ,levelling watering and well ramming of soft/loose soil in layers n exc 25 cm thick complete all as specified and directed.
34Removing excavated soil not exceeding 50 m distance and depositing where directed at alevel n exc 1.5 metre above the starting point complete all as specified and directed.
35Material and labour for reinforced cement concrete design mix M-25 (using 20 mm graded aggregate)as in columns, pillars, piers, posts and struts complete all as specified and directed.
36Material and labour for reinforced cement concrete design mix M-25 (using 20 mm graded aggregate)as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
37Material and labour for reinforced cement concrete design mix M-25 (using 20 mm graded aggregate) as in chajjas complete all as specified and directed.
38Material and labour for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
39Material and labour for Brickwork with subclass 'B' old size bricks, straright or corved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed.
40Use and waste formwork to sides of concrete foundations, footings, bases of col umns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; rough finished surfaces of conrete flat complete all as specified and directed.
41Use and waste formwork to sides of squar ,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions rough finished surfaces of conrete flat complete all as specified and directed.
42Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs,etc rough finished also splays between floors and beams, etc complete all as specified and directed.
43Use and waste formwork to soffits of suspended slabs such as roof slab , floor slabs , landing ; and similar work not exc 200mm (horizontal or sloping) thick; rough finished surfaces of concrete flat complete all as specified and directed
44Use and waste formwork to chullah hoods, chajjas, troughs and similar items in cluding edges, rough finished surfaces of conrete flat complete all as specified and directed.
45Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide ,rough finished surfaces of conrete flat
46Material and labour for Mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
47Mild steel TMT bars 6 to 8mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
48S&F pressed steel frames for doors of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed, Size of fame
49S&F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type , both face is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed.
50Supply and fixing Pressed Steel Windows/Ventilator using box type hinges, MS Spring Latch, MS tower Bolt and telescopic stay complete complete all as specified and directed.
51S&F Aluminium anodised,barrel tower bolts 150 mm of extruded section and fixed complete all as specified and directed.
52S&F Aluminium alloy, anodised,sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
53S&F Butt hinges of 125 mm size, Medium weight, cold rolled mildsteel and fixed, complete all as specified and directed.
54S&F extruded aluminium alloy handles, fabricated type., anodised Size of handle in mm 125 complete all as specified and directed.
55M & L for treating the top surface of filled earth at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface complete all as specified and as directed.
56Material and labour for mild steel small articles as holdfasts etc complete all as specified and directed.
57Material and labour for cement concrete 1:3:6 Type C 1 (using 20 mm graded aggregate) in filling around pressed steel frames and bed blocks etc complete all as specified and directed.
58M&L for 100 mm thick PCC 1:4:8 type D-2(using 40mm graded stone aggregate) as in sub base complete all as specified and directed
59M&L hardcore of broken stone or bolder of gauge n exc 63mm, deposited spreaded , levelled in layers n exc 15 cm thick watered and rammed to true surface all as specified complete all as specified and directed.
60M&L for rendering 15 mm thick in cement mortar 1:6 on brick work or concrete surface of walls finished fair and even complete all as specified and as directed.
61M&L for rendering 5 mm thick in cement mortar 1:3 on fair faces of ceiling, chajjas of concrete surface, finished even and smooth complete all as specified and directed
62M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed.
63M&L for preparing the new plastered surfaces and applying two coats of OBD over a coat of Primer on walls all as specified and direcrted.
64M & L for treating the soil along with external perimeter of building at the rate of 2.25 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per metre of the perimeter wall complete all as specified and as directed.
65M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLHS in and in PVC casing & caping/conduit of suitable size duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm FRLHS PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light/ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge.
66All as per item No. 65 here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLHS PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed.
67Supply and fixed sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 3 modules complete all as specified and directed.
68-do- all as per item No 67 above but for 6 modules complete all as specified and directed.
69Supply and fixed ceiling rose, 3 ph plastic round PVC/polycarbonate isolated body for mounting ceiling fan/exhaust fan/light fittings complete all as specified and directed.
70Supply and fixed modular cover plate with frame for fixing of modular switches/sockets for 3 modules complete all as specified and directed.
71-do- all as per item No. 70 above but for 6 modules complete all as specified and directed.
72Supply and fixed switch piano modular flush type 5/6 Amps 230V AC complete one way complete all as specified and directed.
73S & F surface and wall mounted LED batten 4feets with 1x20W indoor decorative luminaries with and including electronic driver and 1x20W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings complete all as specified and directed.
74Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
75S&F sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified.
76S&F MCB 6 to 32 amps single pole amp rating 240V, 10KA breaking capacity 'C' Curve complete all as specified.
77S&F MCB DP 40 amps 240 volts 10KA breaking capacity 'C' Curve complete all as specified.
78Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
79Supply and laying DWC 50mm pipe SN8 laid in trenches for protection of cable all as specified and directed by the Engr-in-Charge.
80Supply and fixed sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 3 modules complete all as specified and directed.
81S&F modular switch socket outlet multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55809294
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 31 Lakhs
LAST DATE 06-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Store Room At 9 Rajput And Special Repair To Bldg No P-2 At 274 At Tezu Under Ge (P) Lohitpur
Basic Detail
Tender No 8701/12/2025-2026/E8
Bidding Type Tender
Location
City Lohit
State Arunachal Pradesh
Key Dates
Publish Date 17 Jun 2026
Submission Date 06 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 31 Lakhs
Tender Fee 500
EMD 62000
Exemption Available
Document List
46d1d41e-f5aa-4498-8fe6-ad41936edae5.html
BOQ_861779.xls
TD12.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Jul 06, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Jun 25, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

46d1d41e-f5aa-4498-8fe6-ad41936edae5.html

xls

BOQ_861779.xls

pdf

TD12.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders