| 1 | Safe Carriage of following materials from Elec. Store Center Unnao to work dump site along with loading unloading and propoer stocking. |
| 2 | S.T. Pole 11 mtr long |
| 3 | Other loose line materials with including conductor, PVC Cable, Single and double Pole accessories, complete stay & earthing, insulator, Channel, S/S Angle etc. from Elec. Store Center Unnao to work dump site along with loading unloading and propoer stocking. |
| 4 | Three Phase A.B. Cable of diff. size |
| 5 | LT PVC Cable size 1x400 sq mm |
| 6 | LT PVC Cable size 1x120 sq mm |
| 7 | Safe Carriage of following T/F from Elec. Store Center Unnao to diff. work dump site along with loading unloading and propoer stocking. |
| 8 | T/F 250 KVA 11/0.4 KV |
| 9 | T/F 100 KVA 11/0.4 KV |
| 10 | T/F 63 KVA 11/0.4 KV |
| 11 | Dismantling of following Transformer by opening of H.V./L.V. connections and its removal from Plinth / Double Pole with Safe Carriage from work site to dump site along with loading unloading and propoer stocking. |
| 12 | T/F 100 KVA 11/0.4 KV |
| 13 | T/F 63 KVA 11/0.4 KV |
| 14 | T/F 25 KVA 11/0.4 KV |
| 15 | Fixing of 11 KV D.O. Fuse Set at Double Pole with D.O. Fuse mounting Channel, clamps and nut & bolts including all associated work. |
| 16 | Supply & Fixing of following materials for above job- |
| 17 | 11 KV D.O. Fuse Set |
| 18 | D.O. Fuse mounting Channel |
| 19 | Clamp for mounting Channel with N&B |
| 20 | Construction of masonry type T/F plinth, suitable for mounting of distribution transformer. Size of the plinth will be 1.5 mtr x 1.5 mtr x 1.5 mtr (LxBxH) solid with brick work. 75 mm thick C.C. in ratio 1:4:8 with cement, coarse sand and brick ballast laid on the base and 75 mm thick done on all the exposed sides to the plinth as per RESPO norms. (All the material will be arranged by the contractor) |
| 21 | Placement of 11/0.4 KV T/F from dump site to newly constructed T/Fs Plinth & installation and commissioning of 250 KVA T/F and All the jumpering & connection with the system are included in the scope of work. (All the required materials for above job shall be provided by contractor except 250 KVA T/F) |
| 22 | Supply & Fixing of following materials for above job- |
| 23 | Al. Lugs for 250 KVA T/F @ 04 nos. for each T/F |
| 24 | Copper L-piece of appropriate size @ 04 nos. for each T/F |
| 25 | Insulated Lead of Single Core Al. Cable of size 25 sqmm for HT side connection @ 30 mtr for each 250 KVA T/F |
| 26 | Earthing of Neutral of Transformer & Transformer body by way of boring and lowering of ‘B’ class G.I. Pipe 1.5” dia from ground up to the water level (Minimum 40 ft. Deep) with a solid cone at the lower end of G.I. pipe. Connecting and bringing out contineous G.I. Strip size 32X5 mm. from the cone to the ground surface where it will be connected with G.I. pipe clamp from which Transformer neutral & Body connection being done by G.I. Strip as per RESPO norms . (All the material will be arranged by the contractor) |
| 27 | Supply & Fixing of Henley Type Tailless Unit Protection Cubical Panel 500 A, 650 V for 250 KVA DT including all associated work as per RESPO Norms. (All the material will be arranged by the contractor) |
| 28 | Laying of LT PVC Cable of size 1x400 sq mm from Transformer to LT Fuse Unit system including all associated work. (All the required materials for above job shall be provided by contractor except LT PVC Cable) |
| 29 | Fabrication and erection of Distribution Transformer fencing around Transformer and L.T. Distribution Pillar Box with 01 nos. gate & locking arrangement including cost of M.S. Angle size 40x40x5 and M.S. Flat size 25x5, fixing of welded steel wire fabric on steel frames by welding of 10 SWG wire fabric, including Painting of two coats of paint in iron based surfaces with ready mixed paint to give bus green shade including cleaning of oil & dust as per RESPO norms. (All the material will be arranged by the contractor) |
| 30 | Mounting of following Transformer on double pole including its cartage and dragging from dump site to pit site & installation and commissioning of T/Fs and All the jumpering & connection with the system are included in the scope of work. (All the required materials as 08/12 nos.-Al. Lugs as required for each T/F, Nut & bolts for S/S Angle etc for this job shall be provided by contractor except T/Fs, LT PVC Cable & MS S/S Angle) |
| 31 | T/F 100 KVA |
| 32 | T/F 63 KVA |
| 33 | Supply & Fixing of Insulated Lead of Single Core Al. Cable of size 25 sqmm for HT side connection @ 30 mtr for each 100 KVA T/F |
| 34 | Supply & Fixing of LT Fuse Set Protection Unit for 100 KVA DT SMC Box (All the required materials as Al. Lugs, Clamps, N&B etc. for above job shall be provided by contractor) |
| 35 | Supply & Fixing of LT Fuse Set Protection Unit for 63 KVA DT SMC Box (All the required materials as Al. Lugs, Clamps, N&B etc. for above job shall be provided by contractor) |
| 36 | Laying of LT PVC Cable of size 1x120 sq mm from Transformer to LT Fuse Unit system including all associated work. (All the required materials for above job shall be provided by contractor except LT PVC Cable) |
| 37 | Earthing as per RESPO Norms. |
| 38 | Laying stringing and sagging of O/H Three Phase L.T. Line by ABC of diff. size including all associated work with joint/jumpers and binding of insulator as required. |
| 39 | Supply & Fixing of following materials for above job- |
| 40 | Suspension Clamp for ABC |
| 41 | Dead End Clamp for ABC |
| 42 | Eye Hook |
| 43 | L.T. Clamp with Nuts & Bolts |
| 44 | Piercing Connector |
| 45 | Safe Carriage of following T/F from work dump site to Electricity store center Unnao with loading, unloading and proper stocking. |
| 46 | T/F 100 KVA 11/0.4 KV |
| 47 | T/F 63 KVA 11/0.4 KV |
| 48 | T/F 25 KVA 11/0.4 KV Please Enable Macros to View BoQ information |