| 1 | SH-I : ELECTRICAL WORKS |
| 2 | Main Fascia board (Building Announcer)-Refer Design Document: Sign type 1.8 attached in Tender Document Providing and fixing following illuminated signs including all operations from Design, fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-In-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, accordingly weatherproofing techniques and materials shall be used. The sign shoud be compliant with IP 65.Letter face :Providing and fixing Blue Pantone 541C, 5mm thick acrylic. Channel letter face shall be made easily openable for maintainance.Back Channel :Channel letters not less than 60 mm deep would be made out of Stainless Steel to receive the front acrylic and house the controller and LEDs. All the letters would be made in profile to achieve true right angle. All mounting would be done in true plumb and using templet, keeping the alignment of the letters in one level.Lighting:All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots. Cost to include all internal connections and Wiring, terminating and connecting with the cable from the nearest junction box etc along with supplying of 10% spare LED Modules and Drivers.Mounting and structure – Providing and fixing sign frame made out of suitable size MS members (Not less than 50mm x 50mm X 2.5-3.0 mm thick) suitable to withstand heavy winds, P.U.Painted in white colour RAL 9003 to recieve the sign letters of 600 mm in height. Structural design along with its stability shall be approved from a Certified Structural consultant. Bird Spikes: UV Stabilized, extreme temperature proof transparent 75mm high Polycarbonate bird spikes mounted above the signAccessories: Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws, rivets, bolts, washers, nuts, etc. complete as per drawing.NOTE : The scope includes detailed site survey, preparation of artwork and structural drawings etc complete as per site requirements and submission to E-I-C for approval, prior to execution of the work |
| 3 | Regional Language (Content : ಭಾರತೀಯ ವಿಮಾನ ನಿಲ್ದಾಣಗಳ ಪ್ರಾಧಿಕಾರ) (Letter height excluding matras: 600mm) |
| 4 | Official Language (Content : भारतीय विमानपत्तन प्राधिकरण) (Letter height excluding matras : 600mm) |
| 5 | English Language (Content : AIRPORTS AUTHORITY OF INDIA) (Letter height : 600mm) |
| 6 | AAI Logo (Letter height : 1200mm) |
| 7 | Facility Announcers - Building Mounted-Refer Design Document: Sign type 1.7C attached in Tender Document Providing and fixing illuminated signs including all operations from Design, fabrication to installation all complete as per drawings, technical specifications, signage schedule and to the satisfaction of theEngineer-In-Charge. All exterior signs should be manufatured considering harsh outdoor conditions, weatherproofing techniques and materials shall be used.The sign shoud be compliant with IP 65. Proper ventilation & heat dissipation arrangements as required by sign design need to be given by providing louvers / holes in sign frame / back side. Proper maintenance arrangements (provision for opening etc.) should be made to carry out routine / periodical maintenance of signage. The scope includes detailed designing, preperation of artwork, shop drawings etc as per site requirements and submission to E-I-C for approval prior to execution of the workSign Box : The sign box shall be made in 3mm thick aluminium(P.U.Painted in specific blue colour RAL 5013). Router cut, grooved and folded to acheive the desired shape and fixed with the internal frame structures. Sign Face : The sign face shall have laser cut profiles to receive milky white 5mm thick acrylic sheet from back and shall be provided with backlit LED lighting. All panels to be fixed from sides using counter sunk screws. Sign Structure : M .S. square sections 25 x 25 X 2.5 mm, 50 microns hotdipped galvanised Structure and powder coated in RAL 9006. Structure to be directly fixed on the existing building parapet/wall as per site measurements. Structure to receive the sign face.Lighting: All internal illumination shall be using Power LED Lights with electronic controllers, having even spread and overlaps to avoid banding and dark spots. Cost to include all internal connections and Wiring, terminating and connecting with the incoming cable at the site along with supplying of 10% spare LED Modules and Drivers.Bird Spikes: UV Stabilized, extreme temperature proof transparent 75mm high Polycarbonate bird spikes mounted above the signAccessories:Providing and fixing all accessories such as thimbles, end connectors, nut-inserts, screws , rivets, bolts, washers, nuts, etc. complete as per drawingNOTE : The scope includes detailed site survey, preparation of artwork and structural drawings etc as per site requirements and submission to E-I-C for approval, prior to execution of the work |
| 8 | ವಿಮಾನ ಸಂಚರಣೆ ಸೇವೆಗಳು हवाई दिक् चालन सेवाएँ Air Navigation Services |
| 9 | Design, Supply and fixing of Illuminated type Emergency Exit Directional Signages (Wall mounted type) (Refer Design Document: Sign type 2.6a attached in Tender Document ) of Single sided Box type design made out of 1.5mm CRCA MS powder coated white, with Laminated acrylic 5mm thick with graphics in white and green transluscent vinyl on the inside face. All Internal illumination using LED lamps and suitable battery backup of minimum 1.5hr i/c all accessories suitable for wall mounting. (Minimum Dimensions : 150mm H X 400mm W to suit the site requirement/building aesthetics)The scope includes detailed site survey, selection of location, preparation of artwork etc as per site requirements and submission to E-I-C for approval, prior to execution of the work. |
| 10 | Providing and fixing Photoluminiscent signs for identification of Fire Extinguishers/Fire Hose/Fire Alarm/Fire Call Point/Fire Doors/At Fire Door: \\"Push Handle Down to open the door\\"/ At Lifts: \\"Incase of Fire do not use Lifts. Use stairs.\\"/Emergency Escape Direction Signages/Assembly Point Signs (Refer Design Document: Sign type 2.6 b&c attached in Tender Document ) etc of various sizes and shapes to suit the site requirement/building aesthetics by screen printing using artworks provided and with photoluminiscent material as per technical specifications.Screen printing shall be done on self adhesive photoluminiscent vinyl and pasted on 2mm thick powdercoated white (RAL 9016) aluminium plate and fixed at location using screws as per specification and using provided artwork including all operations from procuring the correct materials and made to sizes as specified and approved by the Engineer-In-Charge including all installation activities like marking, alignment and fixing with screws into the wall/cladding/face to the satisfaction of the Engineer-In-Charge. The scope includes detailed site survey, preparation of artwork etc as per site requirements and submission to E-I-C for approval, prior to execution of the work |
| 11 | Providing and fixing of Non-Illuminated type Signs (Wall mounted type) (Refer Design Document: Sign type 2.4 a,b&c attached in Tender Document ) for identification of Washrooms/Drinking Water locations/ Lifts / Service Areas such as Electrical Room/AHU Room/ Electrical Panel / Danger Sign / Survellience by CCTV / Restricted Area / Garbage Collection etc, made of Digitally printed Graphics pasted on 3mm thick acrylic mounted on walls/ claddings/ panelllings using VHB Tape of various sizes/shapes as per site requirements. The scope includes detailed site survey, preparation of artwork etc as per site requirements and submission to E-I-C for approval, prior to execution of the work. |
| 12 | Supply and fixing of Emergency Exit Plan (Fire Life Safety Layout) Signs (Refer Design Document: Sign type 2.6d attached in Tender Document ) of following specificationsa) Material Specification : All signs shall be digitally printed using artworks made specific to each location. Laminated Digital prints on photoluminiscent self adhesive film mounted on 3mm thick white acrylic/Aluminium plate powder coated in White (RAL 9016). Signs shall be provided on a removable transparent acrylic frame with studs for fixing on existing wall surfaces. b) Artworks : The agency shall design the emergency evacuation routes & firefighting equipment location and got the art work approved from AAI before execution.c) Minimum Dimensions : 595 mm X 420mm to suit the site requirement/building aesthetics |
| 13 | Supplying of 3C X 10 Sq.mm XLPE insulated and PVC sheathed, steel strip armoured Aluminium conductor power cable of 1.1 KV grade conforming to IS:7098 (Part-I) complete as required. |
| 14 | Supply and fixing of 32 mm dia (OD) 'B' class G.I. pipe conforming to IS 1239 including fittings like couplers,elbows,tees etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and accessories etc complete as required. |
| 15 | Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface/existing cable tray as required. |
| 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in the existing RCC/ HUME/ METAL pipe as required. |
| 17 | Supplying and making end termination with brass compression gland and aluminium lugs for 3C X 10 Sq.mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 18 | Supply and fixing of Loop in loop out Junction box made out of SMC/powder coated GI with suitable size hinged door fitted with 16A DP MCB,6 way Connector, din bar etc to be mounted on surface including accessories such as clamps/nuts bolts etc. as required as per actual site requirements |
| 19 | SH-II : CIVIL WORKS |
| 20 | Providing and fixing replaceable type name boards made in Tri-Lingual made of vinyl stickering of minimum 100 GSM of approved makes (Mccal, LG,3M or its equivalent) pasted over 03mm thick aluminium sheet of approved brand and manufacturer as per the text provided by Engineer-In-Charge or his Authorized representative including all necessary charges like wastage,transportation, installation, fixing in position etc.Minimum size of the board shall be 400 mm X 100 mm.The size shall suitably adjusted according to the text and language. Please Enable Macros to View BoQ information |