| 1 | Dismantling Of old CC Tiles or Brick or granolithic floors including base concrete and including stacking of dismantled material as directed by the Engineer -in-charge with in a distance of 60 metre(200 Feet) S.No 697 |
| 2 | Dwatering wate upto deep groung level rate also i/c the hier fuel operater T&P for using 2 No of pumping set for disposal of water to the required points & other all arrengments for disposal of water complete. |
| 3 | Dismantling Brick Work or stone work in lime or cement mortar and including stacking of materials as Directed by the Engineer-in-charge with in a distance of 60 meter(200feet) |
| 4 | Deduction cost of old brick bat (SOR UP PWD Supply SI - 1F) |
| 5 | Excavation in foundation in ordinary soil (Loam, clay or sand) Including lift upto 1.50 M. and lead upto 30 M. and including filling watering and rammind of excacated earth into the treaches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 M. from the foundation trenches.(SOR UP PWD SI - 251A) |
| 6 | Extar Rate for Earth Work & Excavation under Water and under liquid mad |
| 7 | Disposal of Excavated Soil up to 5.00 KM distance complete with labour T&P ETC at site. (SOR UP PWD SI - 131(A) |
| 8 | Concrete with 4 cm. gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR UP PWD SI - 273) |
| 9 | Cement Concrete in proportion of 8:4:1 with 4cm guage approved stone ballast, Coarse sand & cement in the materials, labour Tools & plants etc. required for proper completion of the work. (SOR UP PWD SI - 279) |
| 10 | Construction of Granular sub-base by providing Coarse graded Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in ;lace method with rotavator of OMC, and compacting with vibratory power roller to achieve the desired density, complete (As per clause 401 RA) |
| 11 | M-150 Brick work in 1:4 one cement and four course sand, mortar in foundation in plinth including suopply of all material labour, T &P etc. required for proper completion of the work. (SOR UP PWD - 305A) |
| 12 | 12 mm thick plaster with cement and approved fine sand mortar in 1:4 over brick work minium thickness not to be less than 1 Cm including supply of all material labour Tool & Plants etc. required for proper completion of the work. (SOR UP PWD SI - 584) |
| 13 | R.C.C. Work with cement, approved coarse sand & 2 cm guage approved stone grit in proportions of 1:1.5:3 in lintels of door & windows excluding supply of reinforcement and its bending. But including its fixing and binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. (SOR UP PWD SI - 284a) |
| 14 | M.S (tor steel or plain) in Plain work such as R.C.C. or R.B. work including bending for proper shape as necessary inciding bending for proper complition of the work and including supply of all steel & wastage, bend, hooks and authorised overlapping hall be measured (As per analysis) |
| 15 | M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. Same as in item 502 above but in M.S. Grills / Stair case railing / gates / trusher / racks etc. (SOR UP PWD SI -279A) |
| 16 | Painting roofs or other iron work in large areas with one coat priming and one coat of approved (above one Sq. Metre) paint (British antesol or equivalent) including supply of all materials, labour, Tools&plants etc. required for proper completion of the work. Paint to be used IS SOR No 645 |
| 17 | Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour,Tools&plantete. Required for proper completion of the work.New Item |
| 18 | Plain Cement Concrete with 2c.m.gauge approved slone balliast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR UP PWD - 279 A) |
| 19 | Cement Concrete with 2cm gauge approved stone grit, coarse sand & cement in proportion of 1:1.50:3 in cc pavement (theckness as per design) cement coarse & fine aggregate confirming to IS standard mixed in ncrete mixture /Plant of not less then 0.2 cum capacity & appropriate weight batcher using approved mix design, laid in approved fixed form work (steel) channel) laying and fixing of 125 micron thick polythene film, wedges, steel plates including leveling the form work spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including hassion cloth for curring of concrete pavements for not less then 14 days curring compound (where as specified) and water finishing to lines & grade including supply of all material, labour, tools & plants etc. required for proper completion of work and also including complete shifting of Recron 38 fibre reinforcement material etcl & concrete etc. (UP PWD SOR - New Item -9) |
| 20 | Supply of 80mm thick Precast cement concerete I-Shape Interlocking paver blocks ISI mark confirming to IS: 15658-2006 with top layer of minimum 5 mm thickness having plan dimension 200x(160+120mm) of O.P. Cement , smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro-compression mechanism. The compressive strength of concrete paver block shall not be less than 40Mpa and weight 4.5kg per including cost of material, with a blanket layer of 4.00cm. thick fine sand. including labour, T & P etc required for proper completion of the work as directed by Engineer-in-charge. (SOR UP NEW 786 Item No-14) |
| 21 | Laying of 80mm thick Precast cement concerete I-Shape Interlocking paver blocks ISI mark confirming to IS: 15658-2006 with top layer of minimum 5 mm thickness having plan dimension 200x(160+120mm) of O.P. Cement , smooth high gloss finish, skid resistant, manufactured from rubber moulds through vibro-compression mechanism. |
| 22 | Add 18%GST Please Enable Macros to View BoQ information |