| 1 | Supply and Installation of decorative Column light in 3000mm height suitable for 60W LED, IP65 in 3000k. Column light made of GI sheet and have height 2.5mtr above ground level with three spot light of 20W each for area lllumlnation and column with top predesigned laser cut to Illuminate the surroundings with noticeable mode. The column light pole section of 220mmx220mm x 4mm thickness up to 2.5mtr long with three Illuminated portion of 600mm each. The base plate dimension is 209x209x10mm. The control gear tray is prewlred with MCB, terminal connectors for loop In loop out arrangement. Luminaire primarily coated with epoxy resin and top coated with powder coat. All exterior parts are made of stainless steel. Light output of source la more than 110lm/ watt, CRI>70, Surge protection 4k, operating voltage 140 270V, wired with Branded LEDs and driver with efflclency>85%, power factor>0.9, THD<=10%. The CCT of led wlll be 3000/4000/5000 as required by the project. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. Fitting is complete in all aspects with all accessories except foundation bolt. AOR Make:-Vak/Mayfair//K-Light/NERI, KESSLEC |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as requiredAbove 6.5 metre and upto 8.0 metre DSR-2018(Electrical) 11.03.2 |
| 3 | Supply & laying of Al. Conductor PVC Insulated armoured served sheathed cables 1100 Volt grade at a depth of below ground level over a cusion of 750mm below ground level over a cushion of 75mm. thick sand all round and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer Incharge, complete in all respect, the armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per PS No.-501 i)16 sq. mm 4 core Make : Gloster/Universal/ Polycab/ Havells/ Diacab/Grandley/KEI |
| 4 | 2)- 25 sq. mm 3.5 core |
| 5 | 3) 50 Sq.mm. 3½ Core |
| 6 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of E/l.P.S No. 504. i)16 sq. mm |
| 7 | 2)-25 sq. mm |
| 8 | 3)- 50 sq. mm |
| 9 | Supply and burring of Safe Ear-thing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer Gl pipe of 16 swg and inner Gl pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.l. strip will be extra) Make: As approved in U.P P.W.D & C.P.R.I. Certified.(P.S. No 725A) |
| 10 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect (40 Amp TPN). PSNO.807 |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. DSR 2018 14.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal) Make-creator poly extrusion/duraline/rex/times/ narander plast/pioneer |
| 12 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 13 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) '(Bituminous Portion) |
| 14 | Water Bound Macadam |
| 15 | Cementg Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all material, labour, tools & plants etc. requried for proper completion of work (SOR UPLNV, I No. 5.07/SN. 279) Please Enable Macros to View BoQ information |