|
| 1 | Supply and Replacement, Re-installation and testing of damaged, missing AWLR | Supply and Replacement, Re-installation and testing of damaged, missing Automated Water Level Transmitter, non-contact RADAR type sensor, having a measuring range of 0-15 m, including enclosure box and all necessary hardware, cabling with suitable conduits, electrical fittings and accessories, as per technical specifications at designated locations. |
| 2 | Supply and Replacement, Re-installation and testing of damaged, missing 2 AI channel type Datalogger, RTU with GSM and GPRS based telemetry | Supply and Replacement, Re-installation and testing of damaged/missing 2 AI channel type Datalogger, RTU with GSM & GPRS based telemetry including modem, antenna and all necessary equipment for data transmission as per technical specifications at designated locations. |
| 3 | Supply and Replacement, Re-installation and testing of damaged, missing solar panel | Supply and Replacement, Re-installation and testing of damaged, missing solar panel with all connectors cables and suitable conduits as per technical specifications at designated locations. |
| 4 | Supply and Replacement, Re-installation and testing of damaged, missing charger regulator | Supply and Replacement, Re-installation and testing of damaged, missing charger regulator with all connectors, cables and suitable conduit for charging batteries used for providing uninterrupted power supply to Data Collection Platform (DCP), as per technical specifications at designated locations. |
| 5 | Supply and Replacement, Re-installation and testing of batteries with all connectors | Supply and Replacement, Re-installation and testing of batteries with all connectors, cables and conduit for cables for providing uninterrupted power supply to Data Collection Platform (DCP), as per technical specifications at designated locations. |
| 6 | Supply and Replacement, Re-installation and testing of damaged, missing lightening arrestor | Supply and Replacement, Re-installation and testing of damaged, missing lightening arrestor with all connectors, cables and suitable conduits with single point grounding for providing lightning protection to all units including the sensors, data logger and communication units from electrical disturbances and EMF at designated locations. |
| 7 | Supply and Replacement, Re-installation and testing of damaged missing NEMA4X OR Equivalent Enclosure box | Supply and Replacement, Re-installation and testing of damaged, missing NEMA4X OR Equivalent Enclosure box to suit master unit equipment with locking, other ancillary equipment, earthing with all connectors, cables and suitable conduit, mast to mount DCP complete as per technical specifications at designated locations. |
| 8 | Repair, maintenance, restoration, functional and calibration of sensors and Data Loggers for HIS Sites | Repair, maintenance, restoration, functional & calibration of sensors and Data Loggers for HIS Sites installed at various locations, chainage under LGC, PLGC system including upgradation of firmware, softwares repair, replacement of damaged cables, glands, junction boxes and electrical earthing, panel instatement for all communication equipment, sensors, solar power systems, batteries, accessories etc., along with associated civil work and site clearance, necessary painting and restoration etc. complete as required for uninterrupted functioning of all sites. |
| 9 | Functional testing for data transmission accuracy, along with integration at data centre | Functional testing for data transmission, accuracy, along with integration at data centre at Lucknow through GSM, GPRS communication network complete including annual charges for GSM, GPRS communication, cloud storage, server charges as required for uninterrupted data transmission of the all HIS sites. |