| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. DSR No. 1.10.1 |
| 2 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. DSR No. 1.38 |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. DSR No. 1.12 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required. DSR No. 1.32 |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as reauired. DSR No. 1.31 |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit asrequired.25 MM. DSR No. 1.21.2 |
| 7 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC |
| 8 | insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty.System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required forLED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm)40 Watt. DSR No. 8.8.11 |
| 9 | Supply and Installation of Wall Fan complete with gravity louver and connection with 3 core flexible wire as required.400 mm. M.R. |
| 10 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door. DSR No. 2.4.2 |
| 11 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amp. DSR No. 2.13.1 |
| 12 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole. DSR No. 2.10.1 |
| 13 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 14 | 4 X 10 sq. mm+ 2 X 6 sq. mm earth wire. DSR No. 1.14.10 |
| 15 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. DSR No. 1.14.2 |
| 16 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. DSR No.1.14.1 |
| 17 | INTERNETSupplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting up to 10 Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1,Smoke Density - IEC 61034, LSZH standards compliance: NSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. Theouter Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.complete as required.1 Run of Cable. DSR No. 39.18.1 |
| 18 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. DSR No. 39.15 |
| 19 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.Copper Patch Cords of length 1m (3ft). DSR No. 39.13.1 |
| 20 | Supplying Installation Testing and Commissioning of 24 port Cat 6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel.24 Ports Cat-6 Patch Panel should have ETL/ULverification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required. DSR No. 39.11 |
| 21 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking,Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm ToughenedGlass with lock, wall mounting kit, Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.9U Rack. DSR No. 39.23.2 |
| 22 | SITC of 24 Port Switch Cat 6 fully loaded SI Series Approved make. CETS |
| 23 | FIRESupplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. DSR No. 28.2.4 |
| 24 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. DSR No. 28.2.14 |
| 25 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required. DSR No. 28.2.5 |
| 26 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. DSR No. 28.2.6 |
| 27 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/ HFFR outer sheath complete as required. DSR No. 28.5.2 |
| 28 | Air conditioning systemDismentalling of supply air ducting from ceiling to floor cutting. M.R. |
| 29 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,supports, bends, transitions, reducers, end caps,collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings andspecifications of following sheet thickness complete as required.Thickness 1.00 mm sheet. DSR No. 30.12.2.3 |
| 30 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. DSR No. 30.15 |
| 31 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc.as required. DSR No. 30.16 |
| 32 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.25mm.For New & Existing Ducts. DSR No. 30.23.2 |
| 33 | Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators.cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.} at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and offollowing capacities.17000 CMH . DSR No. 30.27.9 |
| 34 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.80 mm dia (50 mm thick insulation). DSR No. 30.2.9 |
| 35 | BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified(insulation complete)80 mm Dia. DSR No. 30.7.1.5 |
| 36 | Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thickMS sheet for pipes of 400 mm dia and above. |
| 37 | 300 MM Dia. DSR No. 30.10.1 |
| 38 | 150 MM Dia. DSR No. 30.10.4 |
| 39 | Add: GST @18% Please Enable Macros to View BoQ information |