| 1 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 3 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects P.S. No. 627 |
| 4 | Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. P.S. No. 628 |
| 5 | S/f of 11 KV Disc insulator 70 KN and fitting B&S heavy duty with clamp of cross arm fixed on ht pole BHEL/ Jai shree / WS/RR make UPERC 19 P No 24 I No 9 |
| 6 | S/f of 11 KV Pin 12 long with insulator of Jai shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC P No 26 I No 7 |
| 7 | S/F of straight MS channel 50x100 mm (9.2 per kg) 1.5 mtrs long including S/E of suitable clamp made of MS flat 50x6 mm including all nuts and bolts fixing on pole. T off channel UPERC P-48 |
| 8 | Supply of Top MS Channel 100x50x2240mm 2.5 Mtr long as per design complete in all respects UPERC P-39 |
| 9 | S/E testing & Commissioning of 63 KVA AI wound outdoor type Transformer as per ISS including fees Complete in all respects Make P.M/Kanohar/LD Power/Peramix as per direction of E/L UPERC P-51 Cost Data book 2019 |
| 10 | S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 |
| 11 | S/F of 11 KV, 100 Amp, Drop fuse set channel type (3 nos) (AOR) |
| 12 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) |
| 13 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) PS. No. 725 (A) |
| 14 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.PS No. 717 |
| 15 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. PS No. 634 |
| 16 | Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I (AOR) |
| 17 | Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100mm, Bottom dia 200 mm and base plate 16mm thik) having 3 mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P complete in all respect. PS No. 649. (Make : Bajaj/Philips/Crompton/Valmont/Transrail) |
| 18 | S/Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. . PS No. 1424 Cat AAA. (Bajaj/Philps/Havells/Crompton) 5 Year warranty |
| 19 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 (Make-Havells/ Grandley/ Polycab/ Diatron/Gloster/Kalinga/KEI) a) 50 sqmm x 3.5 core |
| 20 | 35 sqmm x 3.5 Core |
| 21 | 16 sqmm x 4 Core |
| 22 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504. a) 35 sqmm |
| 23 | b) 70 sqmm |
| 24 | a) 16 sqmm |
| 25 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect PS No. 807 f (ii) 40A TPN |
| 26 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR 14.16.2 a) 90 mm dia (OD-90 mm & ID-76 mm nominal) (Make-CPE/Duraline/Rex/Times/Narender Plast/Pioneer) |
| 27 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. DSR-2018/I.No. 12.38 |
| 28 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x25sqmm complete in all respects as per direction of E/I. (AOR) |
| 29 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x16sqmm complete in all respects as per direction of E/I. (AOR) |
| 30 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint PS No. 623 |
| 31 | Supply & fixing of 100 mm x 110 mm shackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. . P.S. No.621 |
| 32 | Supply & fixing of LED Strip 5 W/M with life L 70/40000 boring hours of reputed LED Make Saffran/White/green datachabe in 1M suitable for 240V AC 30 m of strip for out door use . Complete in all respects as per direction of E/I (AOR) |
| 33 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 34 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate moorum screening, red bajri and labour required. i) bituminious portion (AOR) |
| 35 | ii) water bound macadam (AOR) |
| 36 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 37 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 38 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 39 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) |
| 40 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. PS No 652. (Make : Bajaj/Philips/Crompton/Valmont/Transrail) |
| 41 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect PS No. 1455 (A) AAA. (Bajaj/Philps/Havells/Crompton) 5 Year warranty Please Enable Macros to View BoQ information |