| 1 | Excavation in trenches, n. exc 1.5 m wide and n.exc 1.5 m deep in soft/ loose soil and getting out complete all as specified and directed. |
| 2 | Excavation in trenches, n exc 1.5 m wide and exc 1.5 m but nexc 3 m deep in soft/loose soil and getting out complete all as specified and directed. |
| 3 | M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) mass concrete as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for RCC type A1 (1:1.5:3) using 20mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 5 | M&L for RCC type A1 (1:1.5:3) using 20mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 6 | Form work to sides & soffits of plinth beam and sides of footings getting rough finished surfaces of concrete complete all as specified and directed. |
| 7 | Form work to sides of columns getting rough finished surfaces of concrete complete all as specified and directed. |
| 8 | M&L for MS \\"TMT\\" bars 10mm dia and over in reinforcement, cut to length, bent to shape required including crnaking, bending sprially for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with chips complete all as specified and directed. |
| 9 | All as per Srl item No. 8.00 above but for 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 10 | Removing excavated materials (soil) to a distance .n exc. 150 m and deposting where directed, at a level n.exc. 1.5m above the starting point complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar in any position and removing rubbish off the premises with in 50m complete all as specified and directed. |
| 13 | M&L for Brickwork with subclass 'B' bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed. |
| 14 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and directed. |
| 15 | M&L for Rendering 15mm thick on fair faces of concrete/ brick surfaces in cement mortar 1:4, finished fair and even without using extra cement complete all as specified and directed. |
| 16 | M&L for prepration of new surfaces of plastered wall and applying two coats of exterior emulsion weather proof paint over one coat of exterior wall primer complete all as specified and directed. |
| 17 | S&F for mild steel framed & hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cattle traps & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed. |
| 18 | M&L for mild steel framed work framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete (Fe-410-W(Gde-E-250)quality-A complete all as specified and directed. |
| 19 | S&F of structural steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 20 | S&F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 21 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide complete all as specified and directed. |
| 22 | M&L for 18-20mm thick machine cut Granite stone slab of any type size not less then 0.60 x 1.20 M for on vertical surface, skirting, dado etc. set and jointed in neat cement slurry and pointed in coloured cement to match shade of granite over 15mm thick rendering in CM 1:4 complete all as specified and directed. |
| 23 | M&L for Aluminium Composite Panels (ACP) any colour of exterior edge for cladding near entrance of external wall/ column/ canopy cladding in combination of solid/ Metallic colours, including all necessary frame work and complete weather sealing. The composite panel should consist of 3mm thermoplastic core of LDPE sandwiched between 2 skins of 0.5mm thick aluminium sheet (alloy designation 310S) making a total panel thickness of 4mm. The surface will be furnished with Lumiflon based flourcarbon coating on top sides and service coating on reverse side. Coatings shall conform to specifications of ECCA/ AAMA and conforming to the mechanical properties of panel as per detailed technical specifications. The system shall be fixed using GI brackets and stainless steel bolts and nuts complete with spring washers and cap nuts and all other necessary accessories. The bracket support shall be designed as per manufactures specification and shall withstand a wind pressure of 150 Kg/Sqm. All hardware shall corrosion resistant frame out of anodised aluminium member complete all as specified and directed. |
| 24 | M&L for writting letters or figures (Block, Roman, Italic or Indian) with stainless steel 304 gradde, thickness of steel sheet 2/3mm thick projected type, each letters not exceeding 50mm depth, not exceeding 50cm high and not exceeding 30cm width, fixed at site over granite/ stone/ wall/ plate/ ACP or any other surfaces including necessary fixing arrangements like adhesive/ stainless steel screw, etc complete all as specified and directed. |
| 25 | Dismantling/ demolition posts or struts embedded in soil or concrete etc (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 26 | Excavation in post holes (or similar holes) n exc 0.5 cum getting out in any type of soil returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm and covering and removal of surplus soil n exc 50m and making good surface complete all as specified and directed. |
| 27 | M&L for cement concrete Type D-2, 1:2:4 (40mm graded aggregate) as in walls or retaining walls, any thickness, size or shape including pillasters, butresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 28 | Dismantling wrought iron or mild steel work of any description etc. complete all as specified and directed. |
| 29 | S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting, etc including embeding in concrete and similar work conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 30 | S&F chain link M S Galvanised fencing mild steel galvanised fencing complete all as specified & directed by Engr-in-Charge complete all as specified and directed. |
| 31 | S&F 12mm mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5cm long complete all as specified and directed. |
| 32 | S&F in repair galvanized 2 strand steel barbed wire 2.24mm barbed with 2mm dia barbs at 75mm spacing and straning and fixing to fencing post with staple or steel pins etc complete all as specified and directed. |
| 33 | M&L for preparation of new untreated Steel surfaces of any description, n exc 10cm in width and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. |
| 34 | Surface excavationof soft soil n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 35 | M&L for PCC 1:3:6 type Type b-2 (using 40mm graded crushed stone agg) as in surface channel and drains complete all as specified and directed. |
| 36 | M&L for providing cement concrete type B-1 1:2:4 (20mm graded aggregate) as in copings, complete all as specified and directed. |
| 37 | M&L for providing 50mm thick cement concrete 1:2:4 type B1 (20mm graded aggregate) as in flooring/ subbase complete all as specified and directed. |
| 38 | Continuous brick edging, with width equal to the depth of the brick laid dry on end vertically with well burnt sub class 'B' old size bricks, complete all as specified and directed. |
| 39 | M&L for providing 100mm thick cement concrete 1:2:4 type B 2 (20mm graded aggregate) as in hard standing complete all as specified and directed. |
| 40 | Forming contraction (Dummy) Joints 65mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as specified and directed. |
| 41 | M&L for sand filling under floors or in foundation incl watering and consolidation for laying inter-locking tiles complete all as specified and directed. |
| 42 | M&L for machine pressed precast concrete interlocking paver, block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 80mm thick M-40 Grade, complete all as specified and directed. |
| 43 | M&L for Chequered cement concrete tiles 300cm x 300cm x 25mm thick, set, jointed and pointed in near cement slurry in floors including 15mm thick screed bed in floor complete all as specified and directed. |
| 44 | Disconnecting & dismentling of damaged/ unsv cable any type/ make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 16 Sqmm 4 core, 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable & wrapping PVC tape over XLPE insulation cable and testing complete all as specified directed for following size:-(Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shell be measured & paid seperately) |
| 45 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 46 | Returning filling in foundation/ trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 47 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. |
| 48 | Sand cushioning for under ground cable with locally available sand for protection of cable 8 cm before laying cable and 15 cm deep over the cable including spreading and consoildations complete all as specified and directed. |
| 49 | Supply and laying in replacement sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed. |
| 50 | S&F for 40mm bore GI pipe, light grade, ISI marked including fittings such as bends, tees, sockets etc. fixed on wall/ pole laid in trenches under road crossing/ hard standing including taking down old unsv GI pipe complete all as specified and directed.Note:- Excavation & earth work, shell be measured & paid seperately |
| 51 | Supply and errection of steel tubular swaged pole type 410, SP-31 (9 mtrs long pole) as per IS:2713 (Part-I to III). 1980 complete with cast iron base plate, pole cap, mild steel bolts, nuts & screws including taking down old unsv pole complete all as specified and directed. (a) Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep for pole foundation and getting out in soft/ loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:8 type D-2 (40mm graded crushed stone aggregate) in foundation 900mm x 600mm cross section and planting depth 1.5 mtr for concrete encassing the pole upto GL complete all as specified and directed.(c) M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/ collar above GL 500mm high and 450mm dia complete all as specified and directed.(d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surfaces complete including painting of 30 cm wide bands 3 Nos with synthetic emamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block.(e) M&L for writting letters or figures (Block, Roman, Italic or Indian) with thick synthetic emamel paint of apprised shade not exceeding 5 cm heigh including numbering of pole complete all as specified and directed. (Note : Manufacture's test certificate will be produced before execution work). |
| 52 | S&F in repair LED street light luminaires 90 watt with pressure aluminium -die - cast powder coating housing & frame with heat resistant, high efficiency toughned glass with EPDM gasket for IP-66 protection complete asembly with LED, driver & accessories pre-wiredup to terminal block including connection on pole or building taking down old unsv street light fitting complete all as specified and directed. |
| 53 | S&F in repair LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 54 | S&F in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 55 | S&F in repair PVC junction box of size 130 x 180 x 77mm including two No aluminium bus bar of 2mm thick dully fitted on the suitable insulators with fixing with 35 x 6mm MS flat iron clamp with nut bolt and washers and including one MCB SP 6 Amp with rail fitted in PVC box incl. suitable size cable hole and gland complete all as specified and directed. |
| 56 | S&F in replacement of PVC insulated PVC sheathed copper conductor cable 1.5 Sqmm three core including PVC conduit 20mm size complete all as specified and directed. Please Enable Macros to View BoQ information |