| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in charge. |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 6 | Hard drawn steel wire fabric,Fabrication of iron work of small size and section such as holding down bolts,hold fast,tie rods,grating etc.(when not wrought to required from including supply of steel and its wastage including cost of bolts,nuts if required for and welding,grinding and making,holes as required for completion. |
| 7 | Providing and fixing ISI marked oxidised M.S.sliding bolt 16mm dia nuts and 300 mm long with necessary screws etc completenas. |
| 8 | Providing and fixing ISI marked oxidised M.S.tower bolt 10mm dia nuts and 100mm long with necessary screws etc completenas. |
| 9 | Providing and fixing ISI marked oxidised M.S.door handles 75 mm long conforming to IS:4992 with necessary screws etc completenas. |
| 10 | Providing and fixing galss panes with putty and glazing clips in steeel doors,windows,clerestory windows all complete with 4 mm thick galss panes. |
| 11 | R.C.C work with cement approved coarse sand and 20 mm gauge approved S/grit in the proportion of 1:1.5:3 in lintel, beam and slab excluding supply of reinforcement and its bending the same with24 BWG binding wire and including all centerimg and shuttering etc and curing and supplying also etc required for proper completion of the work cost of binding wire being include in the item |
| 12 | 2 cm.(3/4') thick damp proof course with cement approved corse sand 1:2 with and including water proofing materials as orderd by the engineer in charge in the proportion as specifed by the manufacture including supply of all materials, labour and tools and pla nts etc, required for proper completion of work including proper curing and shuttering as necessary. |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Mild steel and Medium Tensile steel bars). |
| 14 | 12mm plaster with cement approved coarse sand of mortar in 1:6 i/c all labour T & p etc required for proper completion of the work. |
| 15 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. (DSR-13.80) |
| 16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 17 | Supply / Fixing of Flush door of iron i/c all comp. |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm). |
| 19 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete |
| 20 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 21 | Painting or varnishing new iron work in small areas or new work with one coat of ready mixed priming paint and one coat of appr-ved superior quality readymixed enamel paint of varnish include-ing sand papering, rubbing and cleading the surface and supply of all material labour & T/P required for proper completion of the work.(for door and ventilator both side ). |
| 22 | Earth Work In Surface Excavation Not Exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and didposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: |
| 23 | P/L in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level 1:1½:3 ( 1 cement : 1½ coarse sand (zone - III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 24 | Providing and laying in position cement concrete of specifed grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 ( 1 cement : 2 coarse sand (zone - III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 25 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand). |
| 26 | 12mm Cement Plaster Finished With a floting coat of neat cement of mix : 1:3 (1 cement : 3 fine sand). |
| 27 | Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 28 | Steel Reainforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing in Position And Binding All Complete Upto Plinth Level. Themo-Mechanically Treated Bars Of Grade Fe- 500D or more. |
| 29 | Providing M.S. Foot Rests Including Fixing in Main Hole With 20X20X10 cm cement concrete blocks 1:3:6 |
| 30 | Providing And Fixing Of Soil, West And Vent Pipes: 75 mm diameter, Centrifugally cast (spun) iron socketed pipe as per IS: 3989. |
| 31 | Providing And Fixing Terminal Guard: 75mm, Sand Cost iron S&S as per IS - 1729. |
| 32 | Providing And Fixing in position pre-cast R.C.C. Manhole cover And frame of required shape and approved quailty H D - 20, CircularShape 560 mm internal diameter. |
| 33 | Cistern (DSR 17.6.1) |
| 34 | wash Besin (550X400mm) (DSR17.7.3) |
| 35 | PVC Connection Pipe (DSR 18.21.1.2) |
| 36 | Bracket (Code No. 1309) |
| 37 | West Jali (MR) |
| 38 | Wast Pipe (17.28.1.1) |
| 39 | PVC Pipe 110 mm (DSR 12.41.2) |
| 40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 41 | 15mm dia nominal |
| 42 | 20mm dia nominal |
| 43 | Elbow (Code No. 7363) |
| 44 | G.I TEE 25 mm (Code No. 1608) |
| 45 | Socket (Code No. 8786) |
| 46 | Long Body Bib Cock (DSR 18.51.1) |
| 47 | WC Pan (DSR17.1.1) |
| 48 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR-17.24) |
| 49 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR-18.48) |
| 50 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 51 | Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. |
| 52 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 53 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 54 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire |
| 55 | Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM |
| 56 | Blank plate for modular plate type switch boards wherever required. |
| 57 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Please Enable Macros to View BoQ information |