| 1 | SH:-1 Maintenanace & EIDay to day Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights by deputing technical staff on all days excluding sunday & Holiday on monthly basis in General shift and as per Terms and Conditions attached:-Staff Details:- |
| 2 | Wireman - 1 No. (Shift- General) |
| 3 | Khallasi - 1 No (Shift- General) |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 5 | Group C |
| 6 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. |
| 7 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 8 | Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 9 | 36 Watt |
| 10 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep fresh air PVC body exhaust fan minimum 1300rpm including louvers and shutter, fixing with suitable arrangement, connection with 1.5 sq.mm. FRLS PVC insulated wire complete etc. as reqd. |
| 11 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of inimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 12 | 72 watt |
| 13 | Supplying of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 14 | 12 -15 watt |
| 15 | SH:-2 RO MaintenanceComprehensive maintenance of 50x4nos LPH R.O. System with Water Cooler i/c two mandatory services per month (cleaning of All Filters), attending complaints within 24 working hours and replacing the defective parts including Tee, Elbow, PVC pipe with complete overhauling and servicing, excluding filter and cartridge,membrane etc. as required. |
| 16 | Supply & Replacement of following items & extra consumables for testing, commissioing for above R.O. System as & when required. |
| 17 | Spun filter 20\\" |
| 18 | Carbon filter/CTO 20\\" |
| 19 | Adaptor 48 volts |
| 20 | Pump K48 |
| 21 | Cartridge filter 10\\" |
| 22 | R.O. Membrane 80 GPD |
| 23 | SH:-3 Figher Fighting MaintenanceDay to day operation & Maintenance of fire fighting system and fire alarm system complete with wet riser fire pump motors, hydrants i/c water supply pump sets all days i/c sundays and holidays with following minimum staff. |
| 24 | Wireman - 1 No. (Shift- General) |
| 25 | Khallasi - 1 No (Shift- General) |
| 26 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 offollowing sizes as required : |
| 27 | 100 mm dia |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :a) One or more coats on old work. |
| 29 | (a) Dismantling of existing Kirloskar make following capacity Fire Fighting Centrifugal Pump set by part to part with special tools including uncoupling the pump from existing motor, opening of all nuts & bolts of upper casing and motor foundation bolts to facilitate lifting of impeller assembly from lower casing with the help of chain pulley block / heavy labour, loading and unloading of pump from site to workshop and back including labour & cartage etc. complete as required and with the entire satisfaction of Engineer-in-charge.(b) Servicing, overhauling, re-conditioning and re-commissioning of existing Kirloskar make following capacity Fire Fighting Centrifugal Pump set after dismantling the bearing of pump and motor with the help of bearing puller, checking of impeller, mechanical seal, oil seal and all other parts and replacement of all defective parts i.e. Ball Bearing, Mechanical Seal, Shaft Sleeve and minor parts such as nut-bolts, washers, thimbles, sleeves and adjustment/alignment of impeller complete with varnishing connections, testing etc. as required and with the entire satisfaction of Engineer-in-charge (Buy back of scrap are included) |
| 30 | Mechanical Pump of 12.5 HP |
| 31 | Supply, Installation, Testing and Commissioning (SITC) of 12.5 HP Monoblock Centrifugal Pump, complete with TEFC induction motor suitable for continuous duty, having cast iron casing and dynamically balanced impeller, designed to meet required discharge and head, mounted on base frame with anti-vibration pads including alignment and grouting, complete with suction and delivery connections, NRV, valves, foot valve with strainer (if required), pressure gauges, suitable starter, cabling, earthing, and all accessories, including testing, trial run and commissioning, conforming to relevant IS standards and approved makes, complete as required. |
| 32 | Refilling and servicing of various type of fire extinguishers as per IS specification including with testing commissioning at site i/c cartage of extinguisher for site refixing back i/c pdg. Instruction label and inspection slip complete as per required. |
| 33 | CO2 type fire extinguisher of 4.5 kg capacity |
| 34 | ABC type fire extinguisher of 6 kg capacity |
| 35 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd.for suitable dia MS pipe connection conforming to IS 904 as required: |
| 36 | 2 way-100 mm dia M.S. Pipe |
| 37 | Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required. |
| 38 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 39 | Supplying and charging of R-22 R-410//R-134 or any other required refrigerant gas as per requirement in 1.5/ 2TR capacity WTAC/Split AC unit i/c necessary copper pipe, capllary & fiter i/c brazing the tube leakage, finding, pressure testing and vacummuizzing complete as required. |
| 40 | Servicing and complete overhauling of WTAC/Split units after dismantling from various locations, removing of dust from condenser coil, cooling coil and chasis wherever required complete cleaning of fin condenser coil with cleaning agent of superior quality, dismantling of blower motor (if required), washing etc after dismantling of condenser motor replacement of defective parts finally applying two coats of black synthetic paint of approved brand before fixing new 5 mm./6 mm. foam sheet with adhesive testing commissioning etc. complete as reqd. |
| 41 | Fabricating, Supplying & Fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle & \\"T\\" strengthened with intermediate members of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally & vertically and duly welded with wire mesh of size 75 mm x 25 mm made with 6 SWG wire mash of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two Nos. sliding bolts and One No go down lock) having 0.5 mtr. long legs of 40 mm x 40 mm x 6 mm thick angle iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate), up to suitable depth painting with one coat of red oxide & Two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd. |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 43 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 44 | Upto 35 sq. mm Please Enable Macros to View BoQ information |