| 1 | Providing and fixing SS Island Chimney Hood Both side SS Filter with all accessories i/c lighting etc complete as required |
| 2 | Providing and making of duct through 24 Gauge GSS sheet of ducting will fix through high quality material/gaskets etc as required as per direction of Engineer-in-Charge. |
| 3 | Providing and fixing Excel Flow Fan (3 HP) With Box with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 4 | Providing and fixing Starter for Excel Flow Fan (3 HP) with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 5 | Providing and making of duct through 24 Gauge GSS sheet of ducting will fix through high quality material/gaskets etc as required as per direction of Engineer-in-Charge. |
| 6 | Providing and fixing Heavy duty 450 mm Exhaust Fan in Dusting with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 7 | Providing and fixing Heavy duty Off Sliding Grill in Ducting with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 8 | Providing and fixing Ceiling hanging light for kitchen Island with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 9 | Providing and fixing 2x2 40 Watt LED Surface ceiling light with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 10 | Providing and fixing 1x1 24 Watt LED Surface ceiling light with all accessories including testing etc complete as required as per direction of Engineer-in-Charge. |
| 11 | SITC of various sizes water protected outdoor (Water proof) hut type compartmentalized type double door cubical panel both side opening having depth up to 600 mm suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 400A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity of MCCBs and solid copper conductor cable 10 sq mm/ solid aluminium rod for MCBs (approved by Engg in charge) for incoming/Outgoing cables, links for spare MCCBs, heavy duty connectors/ terminals for three and single phase cable connections for MCCBs where as required and marking of location for incoming and outgoing distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dismantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismantling the existing feeder pillar and UG cable. (Panel should be as per design & drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel. |
| 12 | Providing and fixing following rating and breaking capacity Triple Pole 415 V MCCB with thermo magnetic release (With Thermal Magnetic Trip Unit (TMD) with terminal spreaders link in new cubicle panel( item No 11) including drilling holes in cubicle panel, making connections, interconnections , etc. as required. of approved make by engg in-charge.(a) TP 160 Amp/415V, breaking capacity 25 KA |
| 13 | (b) TP 100 Amp/415V, breaking capacity 25 KA |
| 14 | Providing and fixing of maintenance free, dust and moisture free, Engineering plastic injection molding Cooler Body, Cooling pad- 4D honey comb cellulose wet pad with anti bacterial resins fiber body ducting air cooler with suitable DP enclosure mounted in a cubical panels of following specification: Air flow 18000 CMH, Cooling area 1500 sq ft (with 50 feet line up ducting), Motor-Inverter high torque motor 380 to 415 volt/50 Hz, 1.1 Kw (single phase single speed turbo axial fan) with 1400 RPM., Air pressure 180 P.A., Water tank capacity 35 Ltr. etc as per direction of engineer in charge. etc complete as required cooling arrangement by provision of Duct Cooler for kitchen and serve area . etc as per direction of engineer in charge. etc complete as required |
| 15 | Supplying and fixing of 40 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 16 | Providing and laying 4x16 sq mm Copper single core cable in existing wall , conduit pipe etc complete as required Please Enable Macros to View BoQ information |