Tender For Providing Protection Measures Including Design, Supply And Installation In All Respects On The Hillslope Overlooking Trt Outlet, Mat Portal And Switchyard In Power House Area Of Pakal Dul Hydro-Electric Project, Distt.-Kishtwar, J&K.
Tender Overview
Project Description
Tender for Providing Protection Measures Including Design, Supply And Installation In All Respects On The Hillslope Overlooking Trt Outlet, Mat Portal And Switchyard In Power House Area Of Pakal Dul Hydro-Electric Project, Distt.-Kishtwar, J&K.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jun-2026 | Corrigendum1 | Date | 14-Jul-2026 |
| 2 | 25-Jun-2026 | Corrigendum1 | Date | 14-Jul-2026 |
| 3 | 13-Jul-2026 | Extension of dates | Date | 29-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Scaling of Loose rock mass lying on the slope including cost of machineries and disposal of muck within a lead of 100 m as per drawing and direction of Engineer-in-Charge. |
| 2 | Providing and Fixing of ETA certified rockfall barrier with an impact absorption energy of 5,000 kilojoules. Post height of 7 m. Nets of minimum diameter of a single net wire shall be 3 mm and coating thickness min. 150 g/m2, as per the approved drawing and directions of Engineer-in-Charge. |
| 3 | Providing and Fixing of ETA certified rockfall barrier with an impact absorption energy of 8,000 kilojoules. Post height of 8 m. Nets of minimum diameter of a single net wire shall be 3 mm and coating thickness min. 150 g/m2,as per the approved drawing and directions of Engineer-in-Charge. |
| 4 | Providing and Fixing of ETA certified rockfall barrier with an impact absorption energy of 10,000 kilojoules. Post height of 8 m. Nets of minimum diameter of single net wire shall be 3 mm and coating thickness min. 150 g/m2, as per the approved drawing and directions of Engineer-in-Charge. |
| 5 | Providing and fixing of ETA certified high tensile steel Spiral rope net with a minimum tensile strength of ≥ 220 kN/m [consistent tensile strength across all 1 sqm sections] with min. 150 g/m2 coating (95% Zn +5% Al) for corrosion resistance. Rope shall be made of 3 individually 3 mm dia. Wires per strand. Steel Anchors of length 5 m and dia. 32 mm spaced 2.4mx 2.4m in a staggered arrangement along with specialized spike Plates, as per the approved drawing and direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender