| 1 | Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified. |
| 2 | Taking down Aluminium sub main wiring of any description & any position and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed |
| 3 | M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed/surface with PVC rigid conduit / casing & caping medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked 3 mm thick plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following-Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour. |
| 4 | One light/ holder/fan/exhaust/bell point controlled by one switch. |
| 5 | One 5 pin 5 Amp switch socket combination point on an same board. |
| 6 | One 5 pin 5 Amp switch socket combination point on an independent board. |
| 7 | All as per item 3 here in before but for one 15 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS PVC insulated & unsheathed copper conductor single core multistranded complete all as specified and directed. |
| 8 | S&F in replacement of Modular switch one way 6A, 1 module complete all as specified and directed. |
| 9 | S&F in replacement of Switch Piano flush type 5 Amp single pole one way complete all as specified and directed. |
| 10 | S&F in replacement of Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 11 | S&F in replacement of switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed. |
| 12 | S&F in replacement of Modular switch one way 16A, 1 module complete all as specified and directed. |
| 13 | S&F in replacement of Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 14 | S&F in replacement of switch socket combination 5 in 1, 15 Amp flush type complete all as specified and directed. |
| 15 | S&F in replacement of modular type Fan step regulator, 120W - 2 module complete all as specified and directed |
| 16 | S&F in replacement of electronic fan regulator 5 stepped type complete all as specified and directed |
| 17 | S&F in replacement of ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed. |
| 18 | S&F in replacement of MODULAR white or Ivory cover plate with frame, 3 module complete all as specified and directed |
| 19 | S&F in replacement of MODULAR white or Ivory cover plate with frame, 4 module complete all as specified and directed |
| 20 | S&F in replacement of MODULAR white or Ivory cover plate with frame, 8 module complete all as specified and directed |
| 21 | S&F in replacement of Metal Flush box 3 module complete all as specified and directed |
| 22 | S&F in replacement of Metal Flush box 4 module complete all as specified and directed |
| 23 | S&F in replacement of Metal Flush box 8 module complete all as specified and directed |
| 24 | S/fix in replacement of Call Bell Ding Dong AC 230 volts complete all as specified and as directed. |
| 25 | S/fix in replacement of Bell Push AC 230 volts complete all as specified and as directed. |
| 26 | S&F in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed |
| 27 | M&L for sub main wiring with two single core 6.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6.0 Sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- Two runs of 6.0 sqmm FRLS and one run of 6.0 sqmm FRLS copper conductor cable including conduit shall be measured as one unit length.) |
| 28 | M&L for sub main wiring with two single core 4.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- Two runs of 4.0 sqmm FRLS and one run of 4.0 sqmm FRLS copper conductor cable including conduit shall be measured as one unit length.) |
| 29 | Supply and fixing in replacement of VTPN DB 12 way suitable for Mounting MCCB as Incomer of rating 200 Amp Vertical distribution board with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection as required complete all as specified & directed. |
| 30 | Supply and fixing in replacement of MCB distribution board SPN 240 Volt 12 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection as required complete all as specified & directed. |
| 31 | Supply and fixing in replacement of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection as required complete all as specified & directed. |
| 32 | S&F in replacement of MCCB 160 Amp, 16KA, 4 Pole with adjustable thermal & magnetic release, 415 volt including complete electrical connection complete all as specified and directed |
| 33 | S&F in replacement of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection complete all as specified and directed |
| 34 | S&F in replacement of MCB SPN 32-40 Amp, 10 KA, 240 volt 'C' curve complete all as specifed and directed. |
| 35 | S&F in replacement of MCB SP 10 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed. |
| 36 | S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket 240 volt complete with one single pole MCB 20 amps 10KA 'C' curve complete all as specified and directed |
| 37 | S&F in replacement of LED lights fitting 4 Ft, 20W, 220V, AC, batten type, including LED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 38 | S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC batten type including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed |
| 39 | S&F motion sensing LED lights fitting 4 feet, 20 Watt, 220V, AC, energy efficient intelligent sensor power batten type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 40 | S&F in replacement LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 41 | S&F in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 42 | S & F in replacement Building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-66 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 32 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings completed all as specified and directed. |
| 43 | S & F in replacement of LED lamp 9 watt B22 complete all as specified and directed. |
| 44 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable earthing (above GL only) complete all as directed incl dismantling of exsisting earthing. ( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.) |
| 45 | Supply and Laying in replacement of LT cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core incl dismantling complete all as specified and directed. |
| 46 | All as per item 42.00 here in before but of size 50 Sqmm 3.5 Core |
| 47 | All as per item 42.00 here in before but of size 70 Sqmm 3.5 Core |
| 48 | All as per item 42.00 here in before but of size 16 Sqmm 4.0 Core |
| 49 | All as per item 42.00 here in before but of size 10 Sqmm 4.0 Core |
| 50 | S & F in repair of 40 mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clamps and nut and bolts/washer complete all as specified and directed. |
| 51 | M & L Sand cushioning & cover for protection of under grund electric cable in trenches and punning to specified thickness complete all as specified and directed.Note :- (i) Approved dry sand free from vegetation, grass & other deleterious substances shall be used.(ii) For the purpose of payment, only punned thickness shall be measured. |
| 52 | M & L for old size sub class 'B' brick well burnt, laid flat, for cable protection complete all as specified and directed. |
| 53 | Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed. |
| 54 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm thick each layer of any type of soil complete all as specified and directed. |
| 55 | Removing surplus excavated material / soil from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed Please Enable Macros to View BoQ information |