| 1 | Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level. |
| 2 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc. |
| 3 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Soil (exceeding 30cm to 1.5mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Soil (exceeding 1.5m to 3.0mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-in-charge.Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Soil (exceeding 3.0m to 4.50 mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-in-charge.Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Ordinary Rock (exceeding 1.5m to 3.0mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-incharge Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Ordinary Rock (exceeding 3.0m to 4.50 mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-incharge Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 9 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Hard Rock (exceeding 1.5m to 3.0mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-incharge Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in any type of Hard Rock (exceeding 3.0m to 4.50 mtr in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto top, as directed by Engineer-incharge Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 11 | Excavation over areas in any type of soil not exceeding 1.5 m in width or 10 sqm on plan) complete all as specified and directed by Engineer-in-Charge . |
| 12 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Note :- Removal upto 50 m is already included in above item and no extra cost will be paid for removal upto 50mtr. |
| 13 | Returnig, filling in including spreading, levelling, watering and well ramming in layers, n exc 25 cm thick in soil etc complete all as specified and directed by Engineer-in-Charge |
| 14 | Removing exacavated soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge |
| 15 | M&L for moorum/red bajari filling 300mm thick, spread, levelled, rammed, consolidated and rolled with 8 to 10 tonnes vibrator power roller to camber and gradient required including watering and well ramming complete, all as specified and directed.(Note:- Consolidated thickness shall be measured). |
| 16 | M&L for Broken stone or boulders Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 17 | M&L for Screed bed or bedding layer of mortar 25mm thickness for laying floor finishes in CM 1:4 |
| 18 | M&L for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. |
| 19 | M&L for Edge stones to flooring with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and ditto. |
| 20 | M&L for 5mm thiick rubber sheet with fabric backing or insert and plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive |
| 21 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 22 | M&L for PCC (1:2:4) type B2 with 40 mm graded aggregate as in walls or retaining walls,any thickness, size or shape including pilasters, buttresses columns, pillars, boundary and posts pillars etc all as specified and directed. |
| 23 | M&L for providing 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as directed. |
| 24 | M&L for providing 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as directed. |
| 25 | M&L for 18-20mm thick machine cut kota stone slab in flooring,steps over 20 mm thick screed base in cement and sand (1:6) mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 26 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar including 15 mm thick backing coat in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge |
| 27 | M&L for 15-18mm thick machine cut kota stone slab in flooring,steps over 20 mm thick screed base in cement and sand (1:6) mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 28 | M&L for Kota stone slab 15-18mm thick in riser of steps, skirting, dado and pillar including 15 mm thick backing coat in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge |
| 29 | M&L for Machine cut cudappah stone slab 20-22mm thick over and including 15mm thick cement and sand screed in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge |
| 30 | M&L for 16-18mm thick rough dressed Shahabad stone as in floor/ plinth etc over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 31 | M&L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm thick Screed bed etc complete all as specified and directed by Engineer-in-Charge |
| 32 | Demolition of brickwork or stone bouilder masonary built in cement mortar or lime mortar complete all as specified |
| 33 | M&L for brickwork with fly ash bricks straight or curved on plan exc 6m mean radius,built in CM 1: 6 complete all as specified |
| 34 | Taking down cement mortar plaster on brick or stone walls, raking out joints, hacking for key complete all as directed |
| 35 | M&L for dubbing out average 10mm thick in CM 1:6 on irregular face of walls ( when specially ordered i |
| 36 | M&L for external rendering 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over brick or concrete surfaces finished even and fair. |
| 37 | M&L for rendering, 15 mm thick on brick/Stone Masonry/ concrete surfaces in cement mortar 1:6 surfaces finished even and smooth without using extra cement including sagol finished complete all as specified. |
| 38 | M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. |
| 39 | M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement etc including taking down cement mortar plaster on brick or stone walls, racking out joints, hacking for key complete all as specified and directed. |
| 40 | Supply only water proofing compound Make - Scott No 1 conforming to IS-2645 1975. |
| 41 | M&L for preparation of newly plastered surface of wall and apply two coats of OBD over a coat of primer any height including scaffolding etc complete all as directed. |
| 42 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces. |
| 43 | M&L for preparing old plastered surfaces of walls and apply two coat of OBD, finished with roller finish on plastered surfaces of wall any height including scaffholding etc complete all as specified and directed |
| 44 | M&L for 2 mm thick wall care putty etc complete all as specified and directed |
| 45 | Taking down chowkhats or frames not exc.1.5 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge |
| 46 | Taking down chowkhats or frames exc.1.5 Sqm and n.exc 4.00 Sqm each with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge |
| 47 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 |
| 48 | M&L for 1mm thick mild steel sheet earths: covering to door shutters: covering to door chowkats(frames): chullah hoods,: water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivet and fixed to wood or steel memers, etc with plain 40mm lap joints or welded/ riveted seams including bending, turnong up, mitred angles, stopped ends, outlets, etc as required |
| 49 | S&F Powder coated aluminium anodised aluminium frame, shutters for door, windows, ventilators with one or more rebates including joining cleat for fixing etc, rubber / neoprene beading and locking arrangement etc complete all as specified and directed by Engineer-in-Charge. |
| 50 | S&F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 51 | S&F butt hinges medium weight cold rolled mild steel 100mm long. |
| 52 | S&F mild steel barrel tower bolt, stove enamelled black, with bright bolt and fixed 150mm long |
| 53 | S&F mild steel pressed handles, oval type stove enamelled black, 150mm long |
| 54 | S&F 300MM long mild steel Sliding door bolts, plate type Stove Enamelled Black, with bright bolt not less than 12mm dia with and including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 55 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40 mm and fixed in any position any type of opening with and including wooden beads complete all as directed by Engr-in-Charge. |
| 56 | Hacking out old broken glass ( any thickness size ,quality or description ) from wooden/Steel frames glazed with putty or fixed with beads. |
| 57 | M & L for 3 mm thick sheet frosted/pin headed glass ordinary quality and glazing with oil putty or wooden beads in squares n.exc 0.50 sqm in each pane. |
| 58 | M & L for preparation of old wooden surface and applying one coat of synthetic enamel paint. |
| 59 | M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide. |
| 60 | M & L for two coats of synthetic enamel paint over a coat of red oxide primer for old steel surfaces of any description exc 10 cm width or girth including complete removal and preperation of surface complete all as specified and direced by the Engineer-in- charge.. |
| 61 | M & L for preparation of old steel surface and applying one coat of synthetic enamel paint. |
| 62 | S&F curtain rod 20mm dia, having corrugated PVC extrusion on eletric resistance welded MS pipe with fancy type 02 nos Knobs and 02 Nos brackets per each door/ windows etc complete all as specified and directed |
| 63 | Dismantling of unframed work fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section |
| 64 | Dismantling of framed timber scantling 40 Sq, Cm and over in section, in any position |
| 65 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, including ridge & removing all rubbish/ dismantled material outside MD Land all as directed. |
| 66 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 67 | M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners complete all as directed. |
| 68 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet of any colour 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners complete all as directed. |
| 69 | S&F in repairs for false ceiling with Vinyl faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metalized polyester foil backing with Vinyl covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturer's instructions / specification and all as directed including taking down/ out existing. |
| 70 | S&F of steel work of grade ST 240 in Square/Rectangular tubes confirming to IS 4923-2017 or circular section confirming to IS 1161-2014 as in post, trusses, purlin, rafter, bracing etc including weldingand providing special shaped washer etc complete all as specified and directed by Engineer-In-Charge. |
| 71 | S&F of steel work in post, Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. as per Fe 410 -W (Gde- E- 250) quality- A |
| 72 | S&F structural rolled mild steel Fe 410-00 (Gde E-250) as in rafters perlins where connected to common rafters and running rail fixed with angle cleats or other connecting plates etc completed all as specified and directed. . |
| 73 | S&F, structural rolled mild steel Fe 410-00 (Gde E-250) Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 74 | S&F Aluminium wind ties (40x3) mm for roof including securing bolts; as directed, drilling holes, notching for wire, etc.; including all necessary drilling, bolting or riveting, etc., and similar work complete all as specified and directed by Engg-In-Charge. |
| 75 | M&L for Providing cement concrete Type C1 1:3:6 20mm graded aggregate) in kerbs or mud stops, rounded or chamfered on edges including necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 76 | M&L for preparation new or old wooden/steel surfaces any description small aricles such as ends of posts backs of chowkats etc area exc 0.10 Sqm but n.exc 0.5sqm each and treated with tar or coal tar black paint etc complete all as specified and directed. |
| 77 | M&L for MS tubes as in railing for hourse cage cut into required size and shapes welded, embedded in foundation PCC and MS elbow/bends to all corners (size of MS tube 100mm nominal bore medium grade) approved make, framed guard bars, barred iron doors, ladders, shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 78 | S&F mild steel Fe 410-00 (Gde E-250) compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. |
| 79 | S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plug, washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 x 420 mm bowl size 410 x 330 x 160mm including waste coupling, waste pipe etc complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F in 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as directed. |
| 81 | S&F in stop cock/ anglecock cast copper alloy, Chromium plated fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge |
| 82 | S&F fancy type Chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed to bore of pipe 15mm |
| 83 | Supplying and laying 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete all as specified. |
| 84 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe, tank nipple and connected complete all as directed. |
| 85 | M&L for 450mm bore Reinforced cement concrete pipe, type NP-2 laid in trenches and jointed as specified, making necessary connections as existing at site complete all as specified and directed. |
| 86 | M&L for Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in PCC (1:3:6) Type C-2 complete all as specified and directed by Engineer-in-Charge . |
| 87 | Taking down carefully copper/aluminum point wiring (light/ fan/ bell/ socket, power point etc) complete, including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Charge |
| 88 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 89 | One light point controlled by switch 5/6 Amp single pole one way |
| 90 | One fan point controlled by switch 5/6 Amp single pole one way |
| 91 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 92 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 93 | All as per Item No 88 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 94 | S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 95 | S&F Modular Switch, 16 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge |
| 96 | S&F Modular Socket Outlet 6 Amp, 3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F Modular Socket Outlet 6 Amp / 16 Amp - 6 pin combined two module etc complete all as specified and directed by Engineer-in-Charge |
| 98 | S&F Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge |
| 99 | S&F ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge |
| 100 | S&F Double door Sheet metal enclosures factory made DBs SPN, 8 way, 240 volts, protection class IP-42, suitable for fixing of MCBs, confirming as per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar, With Neutral bar, Earthbar and Cable ties for Cable management, Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed.Note:- MCBs will be measured and paid separately. |
| 101 | S&F MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge |
| 102 | S&F MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and fix LED Tubelight fitting 20 W extruded aluminium housing battens are equipped with high specification CISPR 15 compliant Electronic driver and milky white , special polycarbonate diffuser , for glare free efficient light distribution with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply and fix LED Tubelight fitting 22 W extruded aluminium housing battens are equipped with high specification CISPR 15 compliant Electronic driver and milky white, special polycarbonate diffuser, for glare free efficient light distribution with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply & fix energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge. |
| 106 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge |
| 107 | M&L for Supply, laying, connecting, testing and commissioning and jointing, LT underground cable in replacement,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/ walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :- (a) LT cable 10 Sqmm, 4 core.Note : Excavation & Earthwork, pipe protection shall be measured and paid seperetely under relevant item of this Schedule. |
| 108 | Supply & lay HDPE pipe 50 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge. |
| 109 | Taking out/ down and opening of existing ceiling fans 1200 mm sweep, from any position, of any make etc & refixing at the desired location after reassembling and after servicing/ overhauling by thouroghly cleaning the shaft, rotor, stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material / items, making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/ parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/ lubricant etc to make it functional complete all as specified and as directed. |
| 110 | S&F in replacement capacitor 2.5/3 mfd, 250 volts, AC etc complete all as specified and directed by Engineer-in-Charge |
| 111 | S&F in replacement ceiling fan canopy set of two of suitqable size of ceiling fan etc complete all as specified and directed by Engineer-in-Charge. |
| 112 | S&F in replacement Ball bearing No 6201 & 6202 etc complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply and fixing in replacement of down rod of suitable length made out of 15 mm bore medium grade GI pipe with & including clamp, nuts, bolts, split pins, washers, threading etc and making connections to make it functional etc complete all as specified and directed by Engineer-in-Charge. |
| 114 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc |
| 115 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge. |
| 116 | S&F Single pole and neutral enclosure witha two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed by Engineer-in-Charge. |
| 117 | Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI/GI Tee complete all as specified and directed including Excavation & Earth Work. |
| 118 | Supply and lay in trenches/ or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete for following size :-(a) 20 mm boreNote : Excavation & Earthwork shall be measured and paid seperately under the relevant item of this Schedule. |
| 119 | S&F 20 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 120 | Supply and fix gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for for 20 mm bore. Please Enable Macros to View BoQ information |