| 1 | Demolition of brick work built in,jointed,pointed and bedded in any mortar including all quoions, arches pillar etc complete all as specified and directed. |
| 2 | M&L brick work with sub class \\"B\\" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge |
| 3 | Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed. |
| 4 | M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 finished even and fair. complete all as specified and directed. |
| 5 | M & L for preparation of plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed by Engr-in-Charge. |
| 6 | M & L for preparation of old surface and applying two coats of cement based paint complete all as specified & directed by Engineer-in-Charge. |
| 7 | M&L for preparation of old surface and applying one coat of cement based paint complete all as specified and as directed by Engr-in-Charge. |
| 8 | M & L for preparation of old steel surface exceeding 10Cm width or girth and apply one coat of synthatic enamel paint complete all as specified and as directed by Engr-in-Charge. |
| 9 | Dismantling MS work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge. |
| 10 | S & F MS framed work such as grills, gratings, frames,holdfast etc with ends of bars shouldered and or riveted or forgot into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, frame work of water tank and similar work complete all as specified and as directed by Engr-in-Charge. |
| 11 | M & L for preparation of new or previously untreated surface of steel or steel based materials of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by Engr-in-Charge. |
| 12 | Dismantling floor, hearth or wall tilling including cement mortar bedding(but not backing), and rubbish off premises etc complete all as specified and directed by Eng-in-Charge. |
| 13 | M & L coloured non-skid ceramic tiles joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Eng-in-Charge. |
| 14 | M&L glazed ceramic coloured tiles 300mm x 200mm x 6to7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in cement mortar 1:3 complete all as specified and directed by Eng-in-Charge. |
| 15 | Dismantling of cement concrete tiles/designer tiles of any desciption and any thickness in floors, laid, bedded and pointed in any mortar complete all as specifed and directed. |
| 16 | M&L providing chequered cement concrete coloured tiles glossy finish 25cm x 25cm x 22 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment laid over and including screed bed or bedding layer 20 mm thick in CM 1:4 as in floors complete all as specified and directed. |
| 17 | M&L exterior grade heavy duty full body outer designer parking tiles 400x400x10mm, in floors etc. of colour and design as approved by Engr-in-Charge, set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing one including 15mm thick screed bed in CM 1:6 complete all as specified . Make: Kajaria/Orient bell/H&R, Johnson or equivalent. |
| 18 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Engr-in-charge. |
| 19 | M&L for providing 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate , finished even and fair including necessary use and waste of formwork etc complete all as specified and directed by Engr-in-charge. |
| 20 | M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth without using extra cement including necessary use and waste of formwork etc complete all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for 75mm Thick Cement concrete type C-1, 1:3:6 (20mm graded stone aggregate) in Plinth Protection etc. including necessary use and waste of formwork complete all as specified and directed by Eng-in-Charge. |
| 22 | M&L for cement concrete type C2 (1:3:6 ) using 40 mm grade graded coarse agg. in floor,foundations, filling and mass concrete etc. complete all as specified. |
| 23 | Dismantling of paver blocks of any desciption and any thickness in floors, laid dry complete all as specifed and directed. |
| 24 | M & L for rubber moulded precast coloured concrete interlocking paver block any shape and size,with gray cement and pigment glossy finish confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed. |
| 25 | M & L for rubber moulded precast coloured concrete interlocking paver block any shape and size with gray cement and pigment glossy finishconfirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed. |
| 26 | M&L for sand filling under floors as in cusioning and like including watering and consolidation complete all as specified and directed. |
| 27 | M&L for 100 mm thick PCC1:2:4 type B-2 using 40mm graded stone aggregate as in floor etc including necessary use and waste of formwork complete all as specified and directed by Engr-in-charge. |
| 28 | M&L for PCC1:5:10 type E-2 using 40mm graded stone aggregate as in floor etc complete all as specified and directed by Engr-in-charge. |
| 29 | M & L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor Finishing surfaces of concrete topping even and fair complete all as specified and directed by Engineer-in-Charge. |
| 30 | M & L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth with using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 31 | Excavation in trenches not exc 1.5mtr wide and n.exc. 1.50m deep as in foundation of drain n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.. |
| 32 | M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate,as in surface channels and drains filling & mass concrete etc complete all as specified and directed. |
| 33 | M&L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1 : 4 and external face of brick work pointed flush in the same mortar as the work proceeds, complete as specified and directed. |
| 34 | M&L PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in lintels,cills, steps; seismic and other similar bands, plinth courses, string courses, acing courses, parapets and railings upto 60 cm in height, copings,benching,or kerbs kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete as specified and directed. |
| 35 | Returning, filling in, including spreading, levelling, watering and well ramming in layers,soil not exc 25 cm.complete as specified and directed. |
| 36 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point .complete as specified and directed. |
| 37 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, ncluding forms, moulds, mi- tred/stopped ends etc.complete all as specified & as directed |
| 38 | Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using ex- tra cement, ncluding forms, moulds, mi- tred/stopped ends etc.complete all as specified & as directed. |
| 39 | Demolition of cement conc.,reinforced cement concrete of any description and in any position not otherwise specifically provided for |
| 40 | Providing precast cement concrete type B-1 (1:2:4) using 20 mm grade aggregate set in 1:4 cement mortar in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified & as directed. |
| 41 | M&L 10mm dia and over TMT bar, cut to length, bent to shape required for RCC pre cast cover slab, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & as directed. |
| 42 | M&L old size sub class 'B' bricks laid flat in floor, drain bedded,jointed in CM 1:6 and pointed in CM 1:3 including filling of uneven surface with sand, spreading,levelling,and well ramming the surface after dismantling of bricks complete all as specified & as directed.Note: the rates include for embedding bricks in the ground to depths indicated and tamping ground around bricks and also for removing any surplus spoil, etc |
| 43 | Ditto all as above but except bricks |
| 44 | M&L old size sub class 'B' brick work laid on edging with width equal to the depth of the brick, laid on edge and jointing and pointing in CM 1:4 including filling of uneven surface with sand, spreading,levelling,and well ramming the surface after dismantling of bricks complete all as specified & as directed.Note: the rates include for embedding bricks in the ground to depths indicated and tamping ground around bricks and also for removing any surplus spoil, etc |
| 45 | Ditto all as above but except bricks |
| 46 | Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons,drain etc. (each layer) laid , bedded,jointed and pointed in any mortar.complete all as specified & as directed. |
| 47 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri Please Enable Macros to View BoQ information |