| 1 | Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L for rendering 10 mm thick in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately. |
| 4 | M&L 5mm thick, rendering in cement mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for prepration of New plastered External wall surface complete applying the following :-(a) Applying two coat 1.5 mm wall care putty on wall surface and smoothening the surface with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified(b) Applying one coat of Exterior Wall Primer by using Roller over complete all as specified(c) Applying two coat of Exterior Emulsion using Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible |
| 6 | M&L for prepration of New plastered Internal wall surface complete applying the following :-(a) Applying two coat wall care putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified(b) Applying one coat of internal Wall Primer by using Roller over complete all as specified(c) Applying two coat of interior Emulsion Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible |
| 7 | M&L for prepration of New plastered ceiling surface and applying the following :-(a) M&L 1.5 mm wall care putty in two coats on ceiling surface and smoothening the surface with sand papers / Mechanised sanding etc prepatory to paint as directed complete all as specified.(b) M&L two coat of interior acrylic emulsion over a coat of chalk whitening priming by using Airless spray / Roller over complete all as specified . |
| 8 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 9 | PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection complete all as specified and directed. . |
| 10 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifially provided and removing rubbish from the site as complete all as specified and directed. |
| 11 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described below by any one method complete as per manufacturers instructions and directions of GE :- |
| 12 | Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment. |
| 13 | Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment. |
| 14 | Make : Method 1 (Asian paint/ Berger/STP/Fosroc), Method 2 Dr fixit, Pidilite, STP, M/s Texa India Ltd. Gurgaon or Techno commercial equivalent in make mentioned in Appx 'B' approved by GE Note :- (i) The treatment shall be carried out by authorised applicator (through specialized agency as approved by GE.(ii) PCC filling under sunken area will be measured & paid separately (iii) Treatment should be conitue upto 450mm height on vertical wall of sunken but only plan area of sunken will be measured for payment. |
| 15 | PCC 1:5:10, type E-2 (using 40mm graded stone aggregate) as in filling of sunken floors etc complete all as specified and directed. |
| 16 | Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where complete all as specified and directed. |
| 17 | Demolition of mud in roof, any thickness any type of soil including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 150m, where complete all as specified and directed. |
| 18 | M&L for levelling course for roof slab, PCC type B0, 1:2:4 (12.5 mm graded aggrigate) using SBR waterproofing compound for maintaning proper roof slope and finishing surface even and smooth etc complete all as specified and dirceted. Note SBR waterproofing compound measured & paid separately |
| 19 | Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as specified and directed. |
| 20 | OVERLAY- PU BASED ELASTOMERIC LIQUID MEMBRANE SYSTEM FOR EXPOSED ROOF :- Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E-1980-19)/tear strength-20 N/mm (Free film, 14 days + 30 degree C) (ASTM D624) and tensile strength>- 2 N/mm2 (ASTM D4541). (a) After proper surface preparation, apply one coat of primer for PU coating as per manufacturers specificaiton. (b) Apply 1st coat of ShailUrethane(R)BTD (white) @ 650 gm/m2 (minimum) or equivalent by brush/roller white prime surface is tacky, spread waterproofing reinforced glass fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c) Apply 2nd & 3rd coat of ShailyUrethane(R)BTD (white) @ 650 gm/m2 (minimum) or equivalent by brus/roller. Make : Fosroc/sika/choksey/chemsol/Bostik/TP. Note (i) The mimium dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE. (iii) The manufacturer/authorised applicator shall give a warranty for the performace & durability for 10 years. |
| 21 | M&L PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified and directed. |
| 22 | Distmantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and directed. |
| 23 | Distmantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 24 | Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and directed. |
| 25 | Material and labour for Double charge vitrified coloured tiles (approved shade) of size exc 0.36 sqm but not exc 0.42 Sqm having thickness 8 to 9 mm premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed. |
| 26 | All as per sl item No. 22 above but as in skirting, but tiles laid over and including 10 mm thick bedding layer in cement mortar (1:3) complete all as specified and directed. |
| 27 | Material and labour for Double charge vitrified coloured tiles (approved shade) of size exc 0.42 sqm but not exc 1.00 sqm having thickness 8 to 9 mm premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floor, set and jointed using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed. |
| 28 | As per Sl item No. 24 but as in skirting, but tiles laid over and including 10 mm thick bedding layer in cement mortar (1:3) complete all as specified and directed. |
| 29 | Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Dado should be flushed with the wall plastering. |
| 30 | Material and labour for black granite machine cut as in shelves / steps/ cills/ jambs /skirting/border only in tile flooring and the like works and flooring etc, 18-20 mm thick including bull-nose the front length, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and as directed.Note : Single piece should be used in steps/cills/jambs/shelves. |
| 31 | Dismantling of brick work of any type built in cement mortar in any condition etc complete all as specified and as directed. |
| 32 | M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in cm 1:6 etc complete all as specified and as directed. |
| 33 | M&L for half brick thick wall using sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:4 etc complete all as specified and as directed. |
| 34 | Supply and fixing single lever High concealed diverter flow consisting of exposed part kit with operating lever, wall flange & button and concealed body, cartdge sleeve and also including bath spout with flange chromium plated ,screwed down, high pressure complete all as specified and as directed by Engineer-in-charge. |
| 35 | Supply and fixing in repair vitreous china premium/1st quality wash basin (under counter), white/ivory/off white, size 580x430 mm including S&F all accessories as recommended by manufacturer and incl. brass CP bottle trap 32 mm with inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union and incl 32mm brass CP waste coupling and complete fixed in position in all respect as per manufacturer's instructions and taking down existing of any description/size complete all as directed. |
| 36 | Supply and fixing vitreous china premium/1st quality wall hung water closet with P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc., and incl. plastic soft close seat cover as recommended by manufacturer for particular model closed pattern with flat bottom etc; and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete all as specified and directed. |
| 37 | Supply and fixing health faucet (Hand Shower) fancy type, CP including 1.2 meter long 8mm dia wasy flex tube in chrome finish and including wall hook and fixing material, making connections and fixed in position complete all as specified and directed. |
| 38 | Supply and fixing concealed flushing cistern of PVC 8 ltr. cap with dual flushing system, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and 'S' type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including S&F of actuator knob/flush plates and and taking down existing of any description/size complete all as specified and directed. |
| 39 | S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed. |
| 40 | S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete all as specified and directed. |
| 41 | S & F in repair PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed. |
| 42 | Supply and fixing Chromium plated overhead shower 100mm dia with shower arm of 300mm long 20mm dia round shape with 90º bend for wall mounted shower with flange of same make and incl all necessary accessories as recommended by manufacturer for fixing and taking down existing of any description/size complete all as specified and directed. |
| 43 | Supply and fixing towel rail CP 60 cm long between flanges and including all accessories like brackets/screws etc as recommended by manufacturer and complete fixed in position complete all as specified and directed. |
| 44 | S & F stainless steel Kitchen plate rack of overall minimum size 900mm x 750 mm x 250mm deep, with partitions for small/large plates etc made out of stainless steel 0.80 mm thick sheet fixed with rawl plug and CP steel screws complete all as specified and directed. |
| 45 | S&F double bowl stainless steel sink made of 1mm thick sheet for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 915mm x 460 mm and bowl size 410 mm x 330 mmx 160mm with including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete, including taking down old unserviceable sink complete all as specified and directed. |
| 46 | Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 47 | S&F CPVC ISI SDR 11 pipes 20 mm dia with all fitting, including all Brass Fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed. |
| 48 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth. In brick walls complete all as specified and directed. |
| 49 | Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 50 | S&F CPVC ISI SDR 11 pipes 25 mm dia with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 25 mm complete all as specified and directed. |
| 51 | S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm dia bore pipe complete all as specified and directed. |
| 52 | M&L for door seal not less than 40mm fixed with stainless steel screws at the bottom of the door shutters complete all as specified and as directed. |
| 53 | S&F in repair 15 mm dia bore long body bib taps cast copper alloy with on/off handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and as directed. |
| 54 | S&F central hole wash basin mixer 15mm bore brass without polp up waste with 10mm dia 450mm long copper pipes complete all as specified and as directed. |
| 55 | S&F Brass CP wall Mixer for mixing hot and cold water screwed down for iron pipe and fied complete all as specified and as directed. |
| 56 | Supply and fixing in replacement 600mm x 450mm size bevelled edge mirror of selected quality glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including fancy type PVC decorative beading, complete all as specified and as directed. |
| 57 | S&F in repairs cabinet of PTMT with looking mirror of size 450x600mm complete all as specified and as directed. |
| 58 | S&F CP angle valve for 15 mm bore pipe with capstan head long screwed shank including cp cover plate fancy type fixed as in repair complete all as specified and as directed. |
| 59 | S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including CP brass nuts on both sides, complete all as specified and as directed. |
| 60 | S&F toilet paper holder, brass chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed. |
| 61 | S&F CP brass soap dish of fancy type, complete all as specified and as directed. |
| 62 | S&F glass corner self assembly, fancy type, made of 5 mm thick sheet toughened glass of size 250x250mm, fixed with CP brackets, complete all as specified and as directed. |
| 63 | S&F 5 mm thick and 450 mm long glass shelves fancy type and fixed over CP brass brackets complete all as specified and as directed. |
| 64 | Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and as directed. |
| 65 | Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches, joints fixed with pipe joint lubricant complete all as specified and as directed. |
| 66 | Supply & fixing 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed. |
| 67 | S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and as directed. |
| 68 | Dismantling PVC water tank/RCC tank and removing for capacity exceedin 250 litres & not exceeding 500 litres etc., complete all as specified and as directed. |
| 69 | Dismantling PVC water tank/RCC tank of water tanks of capacity exc 500 Ltr & n.exc 1000 Ltr and removing from site complete all as specified and as directed. |
| 70 | S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position including 20 mm ball valve & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and as directed. |
| 71 | S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks Triple layered White coloured (cylindrical, vertical with closed top) ISI marked, hoisted & fixed in position including 20 mm ball valve & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete all as specified and as directed. |
| 72 | Demolition of RCC of any descrition such as a kitchen chimney, chajja, shelves, OHT tanks etc and in any position not other wise specially provided for complete all as specified and as directed. (Note : Reinforcement cut as required to facilitate demolition) |
| 73 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in column, post, pillar, chajjas, slab, shelves etc and setting in mortar complete with joints to match complete all as specified and as directed. |
| 74 | TMT bars 10mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 75 | Use and waste form work to rough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landing and similar work not exceeding 200mm thick complete all as specified and as directed. |
| 76 | Material and labour for Efflorescence treatment to exiting masonry wall complete all as directed and as per following steps and using materials:-STEP 1 - The seepage area from outside & inside shall be marked [consider at least 300mm extra area all around. Old plaster along with brick joint mortar upto 15mm depth shall be removed by mechanical means.STEP 2- After removing of plaster, thorough cleaning shall be carried out by clean water.STEP 3 - The pointing of brick joints shall be carried out by polymer modified mortar Sika MonoTop®-122 F (Compressive strength ≥ 50 MPa in 28days as per ASTM C 109 -7cm cube) along with a bonding primer made by Sika Latex® SBR (Tensile adhesion strength - ≥ 1.5 N/mm2 (concrete failure) as per EN 1542)STEP 4 - The fixing of NRV nozzles shall be carried out in a straight line near to old DPC followed by sealing of nozzles as well as a layer of 12-15mm thick polymer modified mortar shall be applied by Sika MonoTop®-122 F ((Compressive strength ≥ 50 MPa in 28days as per ASTM C 109 -7cm cube) along with a bonding primer made by Sika Latex® SBR Tensile adhesion strength - ≥ 1.5 N/mm2 (concrete failure) as per EN 1542). Allow mortar to cure for 24 hours.STEP 5 - Next day, start injecting the poly acrylic injection Sika Injection®- 306 (with a versatile and adjustable reaction time having mixed viscosity: 3-11 M pa s at + 20 degree C, reaction time: adjustable according to ambient temperature and execution requirement between 8-50 Mins PH - 9-10. Tested as per Wissbau No 2002- 094- (1A) function test with re- injectable hose system) through NRV nozzles and allow product to react so that a seal can be created within the brick work. |
| 77 | STEP 6 - Once the injection work is completed, cut the NRV nozzles and seal with polymer modified mortar.Apply two coats of SikaTop®-107 Seal Plus IN ( Food grade product - CFTRI Certificate for repeated use with aqueous foods / water as per USFDA 175.300 , Tensile adhesion strength ≥ 2.0 N/mm2 as per ASTM D4541 & Water penetration under pressure ~0 mm penetration at 5 bar for 72 h as per BS EN 12390-8) followed by protect it with polymer modified mortar made by Sika Latex® SBR (Tensile adhesion strength - ≥ 1.5 N/mm2 -concrete failure- as per EN 1542). Please Enable Macros to View BoQ information |