|
| 1 | Demolition of brick work or stone/boulder masonry , built in cement mortar or cement lime mortar including all quoins, arches & pillars etc of any description and in any position and removing unserviceable material from work site to outside defence premises complete all as specified and directed |
| 2 | Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubing down with water etc and removing unserviceable material outside defence land complete all as specified and directed. |
| 3 | Demolition of Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided and including removing from site to a distance n exc 500 mtrs , complete all as specified and as directed. |
| 4 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided including removing from site to a distance n exc 500 mtrs , complete all as specified and as directed. |
| 5 | M&L for 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in sub base, finishing surfaces even and fair complete all as specified and directed. |
| 6 | M&L for 75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, finishing surfaces even and fair complete all as specified and directed. |
| 7 | M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete, all as specified and directed. |
| 8 | M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ layingof inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete,all as specified and as directed. |
| 9 | M&L for machine pressed chequered cement concrete tiles 30cmx30cmx25mm thick, with grey cement and pigment, set ,jointed and pointed in neat cement slurry & polished as in floors, laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 10 | S&F factory made precast kerb stones in PCC 1:2:4 type B-1(using 20mm graded crushed stone agreegates) including chamfers, weatherings,throatings etc in smooth finish & set in cement mortar 1:4 including necessary excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed . |
| 11 | S&F 110 mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed . |
| 12 | M&L for plain cement concrete 1:2:4 ,type B1(using 12.5mm graded crushed stone aggregates)as in lintels upto 1.5m clear span, window or door cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings,side posts of precast jallies,benching etc. including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed. |
| 13 | M&L Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brick work masonry, etc., any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed . |
| 14 | M&L for plain cement concrete1:2:4, type B 1 (using 20mm graded crushed stone aggregates) as in walls or, retaining walls, any thickness, size or shape including pilasters, buttresses, columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed . |
| 15 | M&L for use and waste of form work to softfits of walls,retaining walls,abutments,parapet and staircase railing and similar works including attached pillasters,buttresses etc vertical or to batter to achieve rough finished surfaces of concrete complete all as specified and directed. |
| 16 | S&F mild steel work such as in angle iron fencing posts, struts and flat iron fillets, gates etc, including drilling hole, punching,splitting ends to secure chain link fencing or fixing of barbed wire to posts including all necessary cutting, welding bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 quality complete all as specified and directed. |
| 17 | Supply only mild steel galvanized chain link cold dip fencing (4mm dia) of aperature 50mm x50mm complete all as specified and directed. Note: The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made accordingly and contractor shall have no claim on this account. |
| 18 | Fixing only chain link fencing including line wires(steel wire), any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire compete all as specified and directed Note:- Angle iron, flat iron and nuts & bolts shall be measured and paid separately. |
| 19 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line wire to be measured).complete all as specified and directed. |
| 20 | S&F mild steel round bars 10 mm dia, fixed to chain link fencing using 0.90 mm dia GI wire as strengthing bar conforming to Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) complete all as specified and directed. |
| 21 | S&F mild steel screw bolts having dia of neck 5 mm to 10 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n. exc 5 cm long complete all as specified and directed . |
| 22 | M&L for brick work with sub class 'B' bricks, using old size bricks, straight or curved on plan exceeding 6m mean radius , built in cement mortar 1:6 complete all as specified and directed. |
| 23 | All as per Srl item No -22 here-in-before but except bricks complete all as specified and directed |
| 24 | M&L for RCC 1:2:4, type B-1 ( using 20 mm graded crushed stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc and mass concrete complete all as specified and directed . |
| 25 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed . |
| 26 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups , spacers and binders including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surface,surface finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of cement base paint over one coat of primer complete all as per specified and directed. |
| 29 | M&L for preparation of old decorated plastered /concrete surfaces of walls and applying two coats of cement base paint complete all as specified and directed. |
| 30 | M&L for 100mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base, finishing surfaces even and fair complete all as specified and directed. |
| 31 | M&L for 100 mm thick Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in floor, finishing surfaces even and smooth complete all as specified and directed. |
| 32 | M&L for Forming 12mm thick ( thickness of concrete slab 100 mm) expansion joints, the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two parts of sand) complete all as specified and directed. |
| 33 | M&L for plain cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregates) as in surface channel and drain including necessary form work complete all as specified and direc |
| 34 | M&L for extra for forming fair finish drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds mitred/topped ends etc complete all as specified and directed. |
| 35 | M&L Repair to steel gates ( including slot pin, pintol hinge, ball bearing, hook and eye of standarad quality (where required) resecuring of MS plates/sheets and guard bars / grills by using welding equipments complete all as specified and directed. |
| 36 | Taking down shutters of any description exc 1.0 sqm and n. exc 2.0 sqm each and removing from site complete all as specified and directed. |
| 37 | Taking down shutters of any description exc 2.0 sqm each and removing from site complete all as specified and directed. |
| 38 | M&L for Framed work as in doors or gates etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing using Fe 290 (Gde-E-165) complete. complete all as specified and directed . |
| 39 | M&L for Mild steel, plain, black sheet 1.0 mm thick in covering to door shutters, steel gates and similar work, cut to size,edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc.as required complete all as specified and directed . |
| 40 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 41 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described by rubbing with sand paper or grinding by hand grinder to make surface even and smooth & apply primer where required and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 42 | M&L for 75mm thick PCC 1:3:6 , type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection, laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. surfaces finished even and fair including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:2 complete all as specified and directed . |
| 43 | Surface dressing not exc 30cm deep and averaging 15cm deep in any type of soil, adjacent to plinth protection of buildings including uprooting of tiny trees, tree cutting, cleaning, levelling and removing debris to a distance not exc 50 m complete all as specified and directed. . |
| 44 | M&L for grubbing up vegetation, small trees from roots, clean the loose dirt with water and repair the same portion with cement mortar 1:3, touchup with same finish, area not exc. 0.10 sqm each adjacent to CI pipe upto 4th storey building with necessary scaffolding/ ladder complete all as specified and directed. |
| 45 | M&L for granite work 16 to 18 mm thick any colour (table rubbed and polished) in steps, jambs , pillars, window cills , cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite over and including 15mm thick screed bed in cement motar 1:4 including making hole for gas pipe complete all as specified and directed. |
| 46 | Dismantling of plain or corrugated steel/fibre glass/AC sheeting, any gauge in roof covering complete all as specified and directed . |
| 47 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed . |
| 48 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 49 | Dismantling Wall and ceiling boards (fibre,pulp, insulation) or insulation boards/ slabs/ blankets, any thickness, including cover fillets etc complete all as specified & directed. |
| 50 | Providing and fixing false ceiling at all heights with GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture with fully perforated 12 mm thick micro tegular edges, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per BS 476 (Part -4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (Galvanized @120 grams per Sqm incl both sides) comprising of Main T runners of Size 15x32 mm of length 3000mm, cross T of Size 15x32 mm of length 600 mm to form grid module of size 600x600 mm, suspended from ceiling using galvanized mild steel items (Galvanizing @ 80 grams per Sqm) i.e., 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mtr length and L-shape level adjuster of size 85x25x2 mm Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wood screws. The work shall be carried out as per specifications, drawing and as per directions of Engr-in-Charge. |
| 51 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed . |
| 52 | S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries rails and fastening and heavy bracket framing (beam, tee, angle channel or flat sections) including distance pieces, cleats etc confirmimg to Fe 290 (Gde E -165) complete all as specified and directed . |
| 53 | Dismantling of timber scantlings 40Sqcm and over in section, framed work,in any position complete all as specified and directed Please Enable Macros to View BoQ information |