| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 3 | Demolition of cement concrete of ground floors and pavings n exc 15 cm thickness (below or above ground level) concrete including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 4 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 5 | Demolition of RCC of any description and in any position not otherwise specifically provided rainforced (rainforcement of cut as required to facilasite demolition etc) including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 6 | Dismantling asbestos cement (corrugated semi corrugated etc.) sheet in roof covering/ fibre sheets etc complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 Sqms each complete all as specified and directed |
| 8 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 Sqms but n.exc 4.00 sqm each complete all as specified and directed. |
| 9 | Taking down Shutters of any description but exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 10 | M&L Non skid coloured ceramic tiles 7 to 8mm thick of size exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including of 15 mm thick cement screed bed of CM (1:6) complete all as specified and directed. |
| 11 | M & L 10 mm thick Vitrified Ceramic tiles (light shade) of size 60 mm x 600mm polished as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles over & including 15mm thick screed bedding layer in CM (1:6) complete all as specified and directed. |
| 12 | M&L Non-skid coloured ceramic tiles 7 to 8mm thick of size each tiles exc 0.18 sqm n exc 0.36 sqm as in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 13 | M&L Glazed ceramic coloured wall tiles of approved colour of size 350x 250x 7/ 450x300x7 mm thick as on vertical surfaces such as in skirting/dado,etc set and jointed in neat cement slurry and pointed with white or coloured cement to match the tiles over and including 10 mm thick backing coat in CM (1:4) complete all as specified and directed. |
| 14 | Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section etc. complete all as specified and directed. |
| 15 | Taking up or down steel tubing bore of pipe 15 mm and connection, removing clear off site after credit for the same is recovered by the dept., complete all as specified and directed. |
| 16 | Taking up or down steel tubing bore of pipe 20 mm and connection, removing clear off site after credit for the same is recovered by the dept., complete all as specified and directed. |
| 17 | Taking up or down steel tubing bore of pipe 25 mm and connection, removing clear off site after credit for the same is recovered by the dept., complete all as specified and directed. |
| 18 | S&F CPVC pipes, SDR 11, 16 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and directed. |
| 19 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and directed. |
| 20 | S&F CPVC pipes, SDR 11, 32 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets , male and femaleThreaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and directed. |
| 21 | S & F in repairs for 20mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 22 | M&L Cutting and grooving of wall for fixing of CPVC pipe lines and after fixing of CPVC pipe line and making good of all cutting surfaces etc complete all as specified and directed. |
| 23 | S&F in repairs 15 mm dia CP bib tap, fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed. |
| 24 | S&F in repairs 15 mm dia stop valve / angle cock fancy type cast copper alloy ch15 mm dia iron pipe complete all as specified and directed. |
| 25 | S&F in repairs 125 mm size chromium plated shower roses with or without swivel joint including fixing to steel pipe or union etc. complete all as specified and directed. |
| 26 | S&F PVC connections, 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 27 | S&F in repairs Vitreous China Squatting pan, \\"Orissa\\" pattern, size 580 x 440 mm white with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including lime concrete complete including making good to floor. complete all as specified and directed. |
| 28 | S & F in repairs PVC 10 ltrs capacity symphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete fixed in repairs complete all as specified and directed. |
| 29 | S&F Vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed with & including cutting for & pinning in end of brackets and 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure complete all as specified and directed. |
| 30 | S&F in repairs Towel rail 600mm long of brass chromium plated fixed with and including CP brass screws and wooden/plastic cleats. (Minimum weight 190 gms) complete all as specified and directed. |
| 31 | S & F repairs 600mm x 450mm bevelled edge miirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 32 | Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bends etc complete all as specified and directed. |
| 33 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches including taking down of old pipes. complete all as specified and directed. |
| 34 | S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing of stainless steel grating in ground shape etc complete all as specified and directed. |
| 35 | S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specified and directed. |
| 36 | S&F PVC (SWR) junction single (single T or Y ) equal or unequal 110mm dia with access doors complete all as specified and directed. |
| 37 | S&F 110mm dia vent Cowl PVC (SWR) complete all as specified and directed. |
| 38 | S & F 110mm bore PVC (SWR) plain bends, any radius complete all as specified and directed. |
| 39 | S&F Steel windows (fly proof and glazed shutter) made with galvanised steel colour coated/ powder coated (Base steel as per IS 513 'D', galvanised as per IS 277 with zinc of 120gm/sqm) with total coating thickness of 0.60mm (outside for glazing and inside gauged shutter) Sections for frame should be of 72mmx55mm, section for mullian should be 72mm x 50mm section for shutter frame should be 47mmx 20mm and section for fixing glass bead should be 12mm x 12mm and section for fly mesh shutter frame should be 40mm x 20mm mesh fixing should be of 18mm x 0.6mm. Stainless steel wire mesh of 0.45mm dia and average width of aperture 1.4mm shall be used for fly proofing 4mm thick plain sheet glass to be used for glazing of glazed shutters. complete all as specified and directed. |
| 40 | S & F PVC solid ventilator frame size 55 X 47mm with wall thickness of 5mm made out of extruded 5mm PVC sheet, mitre cut at two comers and jointed with 2 Nos of 150mm long brackets of 15 x 15mm MS square tube the two vatted profiles are to be reinforced with 19 x 19mm MS square tube the 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass lowers and cover with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screws and 3 Nos 12mm dia MS guard, bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide primer to MS guard bars etc complete all as specified and directed.Make: SINTEX/ RAJSHRI/ NANDI make as approved by GE. |
| 41 | S&F 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc with one coat of primer complete all as specified and directed. |
| 42 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 43 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 44 | M&L Cutting holes in brick wall built in cement mortor for inserting hold fast and making good the disturbed portion in cement mortor 1:3 depth of embeded portion exc half brick & n.exc one brick etc complete all as specified and directed. |
| 45 | M&L Providing PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in coping, bed plates, filling back hollow portion of chowkats complete all as specified and directed. |
| 46 | S&F 100 mm size butt hinges medium weight, cold rolled mild steel, and fixed complete all as specified and directed. |
| 47 | S&F 150 mm long aluminium anodised barrel tower bolt of extruded section with bright bolt complete all as specified and directed. |
| 48 | S&F 150 mm size aluminium alloy handles, extruded fabricated type, anodised complete all as specified and directed. |
| 49 | S & F Mild steel sliding bolt 300 mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fix complete all as specified and directed. |
| 50 | S & F 35 mmthick 2nd class hard wood factory made glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc divided into squares/rectangular, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I section 8 clause 8.24(a) etc complete all as specified and directed. |
| 51 | M&L Prepation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise described applying two coat of synthetic enamel paint including one coat of pink primer etc complete all as specified and directed. |
| 52 | M&L Prepation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described applying two coat of synthetic enamel paint including one coat of pink primer etc complete all as specified and directed. |
| 53 | S & F 35 mm thick factory Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 54 | Taking down old wire cloth of any description from any frame work and complete all as specified and directed. |
| 55 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed. |
| 56 | S&F of Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size of 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position including MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 57 | M&L Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: stainless steel butt hinges and necessary S S screws shall be paid separately. |
| 58 | S&F of 100 mm long SS hinges medium weight including fixing with SS screws complete all as specified and directed. |
| 59 | Taking down cement plaster from brick/stone wall of any description etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 60 | M&L Rendering 15 mm thick in two coats, 10 mm thick in CM (1:6) and 5 mm thick in CM (1:4) mixed with integral water proofing compound as per manufacturers instructions, on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately. |
| 61 | M&L Rendering 10 mm thick CM (1:6) on fair faces of brick work or concrete surfaces without using extra cement complete all as specified and directed. |
| 62 | M & L forRrendering 5 mm thick CM (1:3) on concrete surfaces of ceiling finished even and smooth without using extra cement in patches n exc 3 sqm each patch incl taking down old plaster complete all as specified and directed. |
| 63 | Supply only water proofing compound complete all as specified and directed. |
| 64 | M & L Preparing newly plasterd wall surfaces of walls and applying two coats of acrylic distemper over and including a coat of primer over and including over and including 3 mm thick in two layers of wall care putty complete all as specified and directed. |
| 65 | M&L Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 66 | M&L Complete removal of existing treatment of old painted wall for internal surfaces and applying two coats of acrylic distemper over and including a coat of primer over and including over and including 3 mm thick in two layers of wall care putty of approved make & shade on walls and other places of up to any height complete all as specified and directed. |
| 67 | M&L Preparation old painted surfaces of walls and applying two coats of Acrylic distemper over a coat of primer up to any height etc, complete all as specified and directed. |
| 68 | M & L Preparation of old plastered or unplastered decorated surfaces of walls and applying two coat of white wash complete all as specified and directed. |
| 69 | M & L Preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 70 | M&L Preparation of ceiling surfaces and applying two coats of white wash complete all as specified and directed. |
| 71 | M&L Preparation of old painted wall surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 72 | M&L Complete removal of existing treatment of external surfaces of wall including removing fungus /algae dirt, oil, grease and loose particles by wire brush, cleaning, washing and removing dust. Cracks less than 2 mm, should be cleaned free of dust with a vacuum cleaner, etc and applying 3.00 mm thick white cement based wall care putty for a smooth finish complete all as specified and directed.Note:-Unit rate quoted shall include for necessary scaffolding, trestles, ladders & cradles required for execution of the work and protective works etc. |
| 73 | M&L 75 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub-base complete all as specified and directed. |
| 74 | M&L 50 mm thick Sand bed filling under interlock tiling including watering and consolidation complete all as specified and directed. |
| 75 | M&L 60 mm thickness, M-35 Grade,Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 with grey cement and pigment complete all as specified and directed. |
| 76 | M&L PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed. |
| 77 | M&L PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) with using water proofing compound @ 2% by weight of cement or as per manufacturer's instructions as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as complete all as specified and directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule. |
| 78 | Taking down of old bituminous tarfelt or any other type of roof treatment from roof/ concrete surfaces and cleaning of the roof surface with wire brush to make it free from dust, dirt etc including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 79 | M&L Application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections on roof slab all as per manufacturer's instructions and zonal specification etc complete all as specified and directed. |
| 80 | M&L 20mm thick screed bed in CM (1:4) duly mixing with water proofing compound at the rate of 2% by weight of cement or as per manufacturer's instructions surface etc complete all as specified and directed.Note: Water proofing compound will be measured and paid separately under relevant item in this schedule. |
| 81 | M & L Providing water proofing treatement with APP based polymeric membrane minimum weighing 3 kg/ Sqm and minimum 3mm thick reinforced with polyester non oven fabric ( weight not less than 150gm/Sqm) as per the directions of manufacturer instructions including cleaning of surface thoroughly from dust, dirt and projections. Laying of membrane by forced ( torch) application with 10cm overlaps . A coat of blown bitumen 85/25 grade @ 1.2 Kg/sqm to be applied on top of memberane, finally coating the surface with bituminous aluminium paint @ 100gm/Sqm complete all as specified and directed. |
| 82 | M&L Chequered cement concrete tiles of size 300mm x 300mm x 20mm thick, with grey pigment ement and pigments set, jointed and pointed in neat cement slurry in floors, the joints shall be grouted and immediately after gouting, the joints shall be pointed flush in CM (1:3) mixed with 150 ml per kg of cement of polymeric based lilquid water proofing additive by weight of cement or as per manufacturers instructions etc complete all as specified and directed. Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately. |
| 83 | Supply only polymer based lilquid water proofing compound complete all as specified and directed. |
| 84 | M&L Making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed. |
| 85 | Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , exc 250& not exc 500 litrs tanks complete all as specified and directed. |
| 86 | S&F Rotational moulded polyethylene water storage tank 3 layer white colour waterr tank , non- toxic effect, algea formation protection (made from Virgin grade of polyetjylene material which is duly stablized with anti-oxident Plastic) of capacity 1000 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 25mm size ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) complete including dismantling existing water tank all as specified and directed. Make: Cat No. HSWS-0100-01-Pure of M/s Sintex |
| 87 | M&L Brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius built in CM (1:6) complete all as specified and directed. |
| 88 | M&L Brick work with fly ash bricks old size, straight or curved on plan exceeding 6.0 metre mean radius in half brick thick walls built in CM (1:4) complete all as specified and directed. |
| 89 | M&L Providing RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in RCC bands supported on walls, beams and columns in floors,roof, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 90 | Use and waste of formwork to sides and soffits o floor or roof beams, beam haunhings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams etc as in rough finished flat surfaces of concrete complete all as specified and directed. |
| 91 | M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and directed. |
| 92 | All as per Item No.91 above,but 5mm dia and over upto and including 10mm dia as in stirrups , spacers and binders etc |
| 93 | M & L Providing precast cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cover slabs (for manholes etc.) and similar articles with plain faces with plain fair faces, including chamfers weatherings, throating etc. and setting in CM (1:4) complete with joints to match etc complete all as specified and directed. |
| 94 | Excavation in trenches n.exc 1.5m wide and not exc 1.5m deep for laying of drain pipes etc or for manhole, etc., and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 95 | Demolition and breaking up of existing RCC Pipe of 150 mm dia set in cement mortar including packing under and haunching & joints in cement mortar and taking out of trenches complete all as specified and directed. |
| 96 | M & L 150mm bore RCC Pipes, Class NP-2 laid and jointed with cement joints complete with collers and laying in trenches complete all as specifed and directed. |
| 97 | M & L Concrete bed of RCC drain Pipe of 150 mm dia with using PCC (1:3:6) type C2 using 40mm graded stone aggregate) including packing under haunching against the size of pipe after they are laid & tested complete all as specifed and directed. |
| 98 | M&L Cutting into existing manholes or connecting new drain making good to pipe of size 300mm dia including rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1 smooth finished and reforming benching as required, complete all as specified and directed. |
| 99 | Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm. etc, complete all as specified and directed. |
| 100 | Removal of excavated soil to a distance n exc 50 mtr and depositing where directed at level n exc 1.5 m above the starting point etc, complete all as specified and directed. |
| 101 | S&F 25 mm outer dia WPVC gate valves, with handle fixing for WPVC pipe and fixed complete all as specified and as directed by Engineer-in-Charge. |
| 102 | S&F in repairs Stainless steel curtain rod of 25 mm dia standard thickness complete all as specified and as directed. |
| 103 | S&F in repairs for stainless steel curtain rod brackets (decorative type) suitable for curtain rod of 25 mm dia, complete all as specified and directed. |
| 104 | S&F in repairs for stainless steel curtain Stainless steel end finals (decorative type) suitable for curtain rod of 25 mm dia, complete all as specified and directed. |
| 105 | M&L HDF (High density Fiber ) board, 18/19 mm thick exterior grade, pre-laminated both side decorative face lamination fixed with screws ,brackets to timber frame work with and including 1st class hard wood, 6 mm thick all around edging, complete all as specified and directed. |
| 106 | M&L HDF (High density Fiber ) board, 12 mm thick exterior grade, pre-laminated both side decorative face lamination fixed with screws ,brackets to timber frame work with and including 1st class hard wood, 6 mm thick all around edging, complete all as specified and directed. |
| 107 | S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised 40 mm width of flap fixed with screws as in repairs complete all as specified and directed. |
| 108 | S & F 125 mm long handles Stainless steel fixed with screws suitable for ward robes complete all as specified and directed. |
| 109 | S & F Stainless steel hasp and stapple 100 mm long including fixing with SS screws complete all as specified and directed. |
| 110 | S F Magnetic Catcher/Drawer Magnet for Cabinet/ Cupboard fixed with screws suitable for Wardrobes complete all as specified and directed. |
| 111 | M&L RCC pipes of size 300 mm dia,class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 112 | M&L Concrete bed to to drain pipes of size 300 mm dia pipes with using PCC (1;3;6) type C-2 (using 40 mm graded stone aggregate) including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed. |
| 113 | M&L Salt-glazed stoneware gully traps, 180mmx150mm square or round mouthed, tvpe 'P' complete all as specified and as directed. |
| 114 | M&L Preparation of newly plastered surfaces of walls and applying two coats of apex ultima weather proof paint over a coat of apex ultima primer as per manufacturers instructions complete all as specified and directed. |
| 115 | M&L 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in plinth protection /paths laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at the junction of wall and plinth protection , at 3 metre interval and every change of direction duly filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth to be sealed with ceiling compound grade ‘A’ complete all as specified and as directed |
| 116 | S&F Roof trusses (framed), trussed, purlins, rafters,rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and directed. |
| 117 | S&F Pre-painted galvalume aluminium zinc coating galvanised based corrugated steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with self tapping (SD) screws complete all as specified and as directed |
| 118 | S&F Pre-painted galvalume aluminium zinc coating galvanised based plain steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as ridge, gutters fixed with self tapping (SD) screws complete all as specified and as directed |
| 119 | M&L 20-25 mm thick machine cut Polished kota stone as in treads of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including bedding layer of 15mm thick in CM (1:6) complete all as specified and directed. |
| 120 | M&L 20-25 mm thick machine cut Polished kota stone as in skirting / riser of staircase laying down and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including backing coat of 10mm thick in CM (1:4) complete all as specified and as directed. |
| 121 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed. |
| 122 | Taking down old unservicieble existing submain wiring of any size and type complete all as specified and directed. |
| 123 | Taking down old unservicieble existing DB's any size and type complete all as specified and directed. |
| 124 | M&L Providing conceled point wiring complete with stranded copper conductor cables in non-metallic PVC conduit 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded drawn including conduit with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLSH conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly for one light/fan point controlled by one, one way switch 5 amps, SP and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed. Note: 1. Modular cover plate with frame and modular metal flux box in the rate quoted. 2. cutting/chases will be measured and paid seperately |
| 125 | All as per Item No.124 above,but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . |
| 126 | All as per Item No.124 above,but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 127 | All as per Item No.124 above,but using 4.0 Sqmm single core FRLSH copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board/AC Point including running of 4.0 Sq mm FRLSH copper conductor PVC insulated cable as earth continuity conductor. Cutting/chases will me measured and paid seperately complete all as specified and directed. |
| 128 | S&F MODULAR switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed. |
| 129 | S&F MODULAR switch 1 way 10 A, 1 Module capacity 230 volts complete all as specified and as directed. |
| 130 | S& F MODULAR socket 5 pin 6 amps 2 MODULE, 230 Volts complete all as specified and directed. |
| 131 | S&F MODULAR socket 6 pin 6/16 amps 2 MODULE, 230 Volts complete all as specified and as directed. |
| 132 | S&F Switch MODULAR 1 WAY 16 amps, 230 Volts complete all as specified and as directed. |
| 133 | S&F 2 MODULE regulator for compatibility with existing ceiling fans MODULAR 5 stepped type complete all as specified and as directed. |
| 134 | S&F Wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W complete all as specified and as directed. |
| 135 | S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 136 | S & F LED light fitting 1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 137 | S&F LED Light fitting 1x35 Watt complete with Bracket made out GI pipe med grade 25mm of L Shape 1.5 Mtr long incl clamps and nuts botls etc , all as specified and as directed. |
| 138 | S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed. |
| 139 | S & F Sheet metal enclosure MCB DB SPN 12 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed. |
| 140 | S & F MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB's complete all as specified and directed. |
| 141 | S & F MCB SPN 32-40 Amps 240 volts for fixing on MCB DB's complete all as specified and directed. |
| 142 | S&F Sheet metal enclosure vertical type MCCB DB TPN 4 way double door with suitable rated bus bar 415 volts suitable for and including MCCB TPN as incomer with suitable rated copper bus bar with neutral link including provision for 100 Amps MCCB 25KA TPN as incomer and SP/TP MCBs as outgoing and total number of modules equal to MCCB TPN + 12 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc, complete all ass specified and as directed. Note: MCB SP/TPN will be measured and paid seperately. |
| 143 | S & F in repair MCCB 100A 16KA complete all as specified and as directed. |
| 144 | M&L Providing earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion all as specified and as directed.Note : The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron funnel with watering pipe, wire mesh, complete. |
| 145 | S&F Exhaust fan of size 250 mm sweep,230V, 50 Hz, 1200 RPM ,copper widing,made of sturdy engineering plastic complete with louvers shutter, voltage including making hole of suitable size complete all as specified and directed. |
| 146 | S&F Exhaust fan of size 300 mm sweep, Phase. 230V,steel body AC single complete with blades, and frame and louvers shutter,Copper winding including making hole of suitable size complete all as specified and directed |
| 147 | M&L Providing concealed sub main wiring with two runs of single core, copper conductor cable of size 6 sqmm, FRLSH PVC multistranded stranded unsheathed and drawing through including PVC conduit of 25mm dia with accessories on surface in wall/roof along with one run of 6 sqmm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed.Note: 3 runs of 6 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. Cutting/chases will me measured and paid seperately. |
| 148 | Taking down ceiling fans 1200/1400mm sweep and exhaust fan 230/300 mm sweep, remaining/cleaning of dust properly cleaning, greasing& overhualing of bearings including refixing and connecting up complete all as specified and directed. Note : Replacement of defective/worn out parts will be measured & paid for separately |
| 149 | S & F in repair capacitor 2/2.5 mfd as directed (Make - Asian/Usha/Epcos of siemens) complete all as specified and directed. |
| 150 | S & F in repair ball bearing of exsiting ceiling fans complete all as specified and directed. |
| 151 | S & F in repair twisted three core copper flexible cable of size 1.5 sqmm from connector to the ceiling rose complete all as directed |
| 152 | S & F in repair ‘U’ clamps complete with nut, bolts & split pins Heavy duty, suitable for existing ceiling fan.complete all as specified and directed. |
| 153 | S & F in repair M.S. rod for ceiling fans 3 ft long with ‘U’ clamp at one end other end with out nut bolts washers or screwed thread with check nuts & pin complete all as specified and directed. |
| 154 | S & F in repair Nut of bolts washers for fan blades fixing of ceiling fan of any make/size/type as per site requirement ( 6 Nos for each set) complete,asuitable for existing ceiling fan.on site complete all as specified and directed. |
| 155 | M & L Rewinding of stator complete with super enameled copper wire of gauge/ weight of copper coil, quick varnishing oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required including cleaning of body and testing of the size 1200/1400mm sweep ceiling fans and 230/300mm exhaust fans of any make/model complete all as specified and directed.Note :- Sapre parts except mentioned above and rewinding to be replaced will be measured and paid seprately under respective items of schedule. |
| 156 | M & L Spray painting of ceiling/exhaust fans of any size with two coat of synthetic enamel paint complete all as specified and directed. |
| 157 | M & L Cutting chases, pining to making good to facing where ever required and pointing in cement motor 1:3 to ends or edges of endings, steps, cills etc and cutting chases for concealed wiring making good and cutting not exceeding10 cm grith complete all as specified and directed. |
| 158 | S&F Geyser 25 Ltr capacity, vertical type, metalic body, ISI marked 2000 Watt heating element with brass connector of series for both outlet and inlet,including installation, testing complete with suitable arrangement of fixing with suitable stud/Anchor fastner including PCC work with drilling holes complete all as specified and directed. Make- Havells/Bajaj/Crompton Greaves. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail