| 1 | Attending complaints and rectification of defects of any type AC, Refrigerator, Desert cooler, Water Cooler, Deep Freezer, Voltage Stabilizer etc and testing complete all as specified and directed.Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M and recorded in the register maintained for the purpose.(ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc shall deemed to be included in the unit rate quoted by the contractor against this item. |
| 2 | Taking down old unsv condensor motor of split type Air conditioner capacity up to 2.00 ton and re-winding to burn out linear coil of copper strip heavy cross sectional area, with insulating material in same gauge copper purity, no of turns in coil with varnishing, heating, testing etc with all other site work required to make the condensor motor serviceable complete including testing and commissioning and reassembling the same after repair complete all as specified and directed. |
| 3 | M&L for Servicing, overhauling and testing of split type/window type AC, capacity 1.5 ton/2.00 Ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration in the equipment including refixing the AC in existing position complete all as specified and directed. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws etc, to be inclusive in the unit rates quoted by the contractor against this item. |
| 4 | Supply & fixing in replacement, new compressor for window/ split type AC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and branded ) complete all as specified and directed. Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge. |
| 5 | Supply & fixing in replacement, new compressor for window/ split type AC 2.00 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and branded ) complete all as specified and directed. Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge. |
| 6 | Material and labour for trickle charging of gas R-22/R-32/R-410 as required in AC of capacity 1.5 ton/2.00 Ton, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed. |
| 7 | Supply and fixing copper capillary tube (suction tube) of 1st quality copper size 1/2\\" and 3/8\\" or 5/8\\" duly complete with insulation suitable for split AC cap upto 2.00 TR including taking down old unsv copper tube complete all as specified and directed. |
| 8 | Supply and fixing copper tube (liquid tube) outer dia as per existing size complete with insulation suitable for split Air conditioner cap upto 2.00 TR including taking down old unsv copper tube complete all as specified and directed. |
| 9 | M&L for disconnect of existing split air conditioner capacity up to 2.00 Ton shiftting and reinstallation, in same Bldg location or another Bldg location incl factory made GI brackets out door mounting unit with nut bolt washer etc complete all as site works complete all as specified and directed. |
| 10 | Supply & fixing nylon type filter pad 20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. |
| 11 | Supply & fixing nylon type filter pad 20 micron for Split type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. |
| 12 | Supply, installation in replacement of two Air conditioner controller system with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls 2 Air conditioner 30-30 Amps, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor,Auto/Manual facility for all ACs complete with all installation accessories complete all as specified and directed. |
| 13 | Supply, installation in replacement of three Air conditioner controller system with LCD Digital Display and Alarm facility for low/High temperature, supply voltage 230 Volts AC, 50 Hz +- 15% separate for each AC, temperature sensing range -15 degree to 80 degree, contact rating 30 Amp at 230 Volts AC for compressor or AC, 5 Amp at 250 V AC for Alarm Potential free outputs, thermostat sensor NTC 10 K @25 degree C,Hi tech Micro controller based technology PLC controller, controller front panel to read all parameter, room high temperature and low temperature alarm facility programmable, controls 3 Air conditioner 30 Amps each, separate heavy duty relay, time show on display, direct display accurate temperature sensing by precise temperature sensor, Auto/Manual facility for all ACs complete with all installation accessories complete all as specified and directed. |
| 14 | Supply and fixing capacitor 50/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unsv capacitor complete all as specified and directed. make- Kell/Tesla/Sharda/Escop/Havells |
| 15 | Supply and fixing capacitor 60/6 MFD, 440 volts clip type suitable for window/split air conditioner 2.00 Ton clip type complete including taking down old unsv capacitor complete all as specified and directed. make- Kell/Tesla/Sharda/Escop/Havells |
| 16 | Supply and fixing capacitor 36/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unsv capacitor complete all as specified and directed. make- Kell/Tesla/Sharda/Escop/Havells |
| 17 | Supply and fixing capacitor 45/6 MFD, 440 volts clip type suitable for window/split air conditioner 1.50 Ton clip type complete including taking down old unsv capacitor complete all as specified and directed. make- Kell/Tesla/Sharda/Escop/Havells |
| 18 | Supply & fixing in repair starting relay suitable for window type AC of capacity up to 2 ton compete all as specified and directed. |
| 19 | Supply & fixing in repair, thermostat switch of working temp 6 degree to 20 degree suitable for window type AC or split type of capacity up to 2 ton complete all as specified and directed. |
| 20 | Supply & fixing, in repair, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. |
| 21 | Supply & fixing blower motor 1/8 HP, double shaft, single phase suitable for split type Air conditioner capacity up to 2 ton including testing complete all as specified and directed. |
| 22 | Supply & fixing condensor fan motor single phase electric motor, 230V, 50 Hz, 1050 RPM, 60 watt fitted with ball bearing suitable for split type Air conditioner capacity up to 2 ton including testing complete including taking down old unsv condensor fan motor complete all as specified and directed. Make: Whirpool / LG/Khaitan/ or equivalent approved make. |
| 23 | Supply & fixing in repair, fan blade for blower motor for window type AC capacity up to 2 ton complete all as specified and directed. Make: Whirpool / LG/khaitan or equivalent approved make. |
| 24 | Supply & fixing in repair, fan blade for condensor motor for split type AC capacity up to 2 ton complete all as specified and directed. Make: Whirpool / LG/khaitan or equivalent approved make. |
| 25 | Supply and fixing condensor copper coil unit of Split Air conditioner capacity up to 2.00 Ton including taking down old unsv condensor coil unit complete all as specified and directed. |
| 26 | Supply and fixing Split Air Conditioner outdoor Mounting stand, MS factory made stand powder coated (as per sample) including zebra bolts & washers, including grouting in wall building works cement works nut bolts and painting extra complete all as specified and directed. |
| 27 | Supply & fix single pole and neutral enclosure (MODULAR AC BOX) 4 module in sheet steel with a two pin and earth plug and socket Cat part No DSDPUSN020 of STANDARD or equivalent in Indoasian /Schneider/Siemens/Legrand complete with one single pole MCB 25 Amp 10 KA complete including taking down old unsv AC box complete all as specified and directed. |
| 28 | Supply and fix MCB single pole and neutral (SP&N) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed. |
| 29 | M&L for providing sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through concealed PVC conduit complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire fixing on wall/ceiling etc complete all as specified and directed. Note : (i) Two runs of single core 4.00 Sqmm multi stranded copper cable and one run of 4.00 Sqmm earth wire and PVC conduit 20 mm shall be measured as one run length (iii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iv) Earth wire run inside the PVC conduit. |
| 30 | Supply & fixing PVC copper conductor cable of size 4 Sqmm 3 core PVC sheathed suitable for supply for outdoor unit and indoor unit complete with taking down old unsv cable complete all as specified and directed. |
| 31 | Supply, installation, testing and commissioning of outdoor units suitable for split type AC 1.5 TR (1500 watts) cooling capacity 5275 watts 5 star rated dual invertor single phase 230 volts 50 Hzs in origional with intallation copper pipe in standard size , compressor, initially gas charging R- 22, condensor motor, condensor coil, factory made GI mounting stand with nut,bolt & washers etc complete with taking down old unsv outdoor unit. Make:- Make:- LG/ Hitachi / Voltas/Samsung/Blue star/Godrej Note : Unsv outdoor unit shall be deposited to MES store yard. |
| 32 | Supply, installation, testing and commissioning of air conditioner indoor units cap 1.5 TR in put voltage 1500 Watt and cooling capacity 5275 W split type suitable for 5 star rated in door unit in origional complete with indoor blower motor, PCB, cooling coil, etc accessories complete all as specified and directed. Make:- Make LG/Hitachi / Voltas/Samsung/Blue star/Godrej Note : Unsv indoor unit shall be deposited to MES store yard. |
| 33 | Supply and fixing power circuit breaker (PCB) kit for split/window type AC complete all as specified and directed including taking down old unsv PCB. |
| 34 | Supply and fixing Inverter power circuit breaker (PCB) kit suitable for Inverter type split type AC complete all as specified and directed including taking down old unsv PCB. |
| 35 | Taking down of Old unsv power circuit breaker (PCB) of Split Air conditioner invertor type, replace of unsv part of PCB by Auth company dealer and refixing the same after repairing of PCB Satisfactory complete all as specified and directed. |
| 36 | Taking down old unsv blower motor of split type Air conditioner capacity up to 2.00 ton and re-winding to burn out linear coil of copper strip heavy cross sectional area, with insulating material in same gauge copper purity, no of turns in coil with varnishing, heating, testing etc with all other site work required to make the blower motor serviceable complete including testing and commissioning and reassembling the same after repair complete all as specified and directed. |
| 37 | Taking down old unsv top plug 3 pin and supply and fixing of 20 Amp 3 Pin Top plug metal clad suitable for AC box as per existing size complete all as specified and directed. |
| 38 | Taking down old unsv socket 3 pin and supply and fixing of 20 Amp 3 Pin socket metal clad suitable for AC box as per existing size complete all as specified and directed. |
| 39 | Supply, fixing & testing new compressor for water cooler of capacity 40/80 Ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. |
| 40 | Supply, fixing & testing new compressor for water cooler of capacity 60/120 Ltr, including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. |
| 41 | S&F, in replacement blower motor 1/3.5 HP with base and clamp, rubber mountings for water coolers including taking out the old unserviceable motor complete all as specified and directed. Make: Universal/Crompton Greaves/Cool king/ American Universal |
| 42 | Supply and fixing blower motor suitable for Deep freezer hard top 200 ltrs capacity having single door any make including taking down unsv blower motor and testing complete all as specified and directed. |
| 43 | M&L for trickle charging of gas F-12 or as required in water cooler, any capacity, after detection of leakage with soap solution/halide torch, making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed. |
| 44 | S&F push type water tap, 15 mm dia, chromium plated,sainless steel heavu duty suitable for water cooler complete all as specified and directed. |
| 45 | S&F, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed. |
| 46 | M&L for preparation of old decorated steel surfaces of Water Coolers including scraping down smoke soot, moulds, moss, salts etc, removing oily & greasy material and applying two coats of synthetic enamel paint of first quality using ‘spray machine’ over one coat of primer including marking of SM/MES Srl No in block letters with black paint complete all as specified and directed. |
| 47 | Supply, fixing & testing new compressor for refrigerator of capacity 286/310 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. |
| 48 | M&L for trickle charging of gas F-12 or as required in refrigerator of capacity 286/310 Ltr, after detection of leakage with soap solution/halide torch, making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all specified. |
| 49 | S&F in replacement freezer assembly suitable for refrigerators of any make, 286/310 ltrs capacity including taking out unserviceable assembly complete all as specified and directed. MAKE : Kelvinator / Zenith / Godrej/ Whirlpool /Voltas |
| 50 | S&F in replacement door panel (AB plastic), suitable for refrigerators of any make, 286/310 litres capacity including taking out unserviceable door panel complete all as specified and directed. MAKE : Kelvinator / Zenith / Godrej / Whirlpool /Voltas |
| 51 | S&F in replacement starting relay for refrigerator of different capacity/make including taking out unserviceable relay complete all as specified and directed. |
| 52 | S&F in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified and directed. MAKE: SHRIRAM or RENUTROL or INDOFOSS. |
| 53 | S&F, in replacement capillary tube made of copper, any size suitable for Refrigerator/Water Cooler including taking out old unserviceable capillary tube complete all as specified and directed. |
| 54 | S&F in replacement capillary filter drier 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified and directed. |
| 55 | Material and labour for servicing & overhauling of desert cooler, any size/type/make including greasing, oiling of fan motor and vertical Pump (Tulu Pump) decarbonising the electric connections, reconnecting cable connection by providing new thimbles, duly PVC insulated the joints as per requirement complete all as specified and directed. |
| 56 | Material and labour for painting desert cooler of capacity 5000 Cu M/hr with spray painting machine with two coats of synthetic enamel paint powder coated (first quality,shade : silver grey as approved of make ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson Paints (BOROLAC) Berger paints (LUXOL HI CLOSS ) and two paint to inner surfaces including preparation of surface and painting inside with black rubber bitumen paints complete all as specified and directed. |
| 57 | Supply & fixing blower motor copper wound 200 watt, 1/8 HP, single phase suitable for desert cooler including testing and taking down old unsv blower motor complete all as specified and directed.Make: Khaitan/crompton/Bajaj. |
| 58 | M&L for taking down existing unserviceable fan motor from desert cooler and replacement of wornout winding, bushes and bearing etc and testing complete, refixing and connecting complete all as specified and directed. |
| 59 | Supply & fixing vertical pump (Fish type) for desert cooler, single phase 230 Volts including taking out unserviceable vertical pump complete all as specified and directed. Make : Khaitan/crompton/Bajaj. |
| 60 | Supply and fixing Water lifting submersible pump suitable for desert cooler as per existing capacity including taking down old unsv pump complete all as specified and directed. (Make : Snow Cool/LITTLE/universal) |
| 61 | Supply & fixing PVC distributor, Tee or elbow of size 15mm for desert coolers including taking out unserviceable distributor complete all as specified and directed. |
| 62 | Supply & fixing selector switch three speed (low, medium and high) suitable for desert coolers including taking out unserviceable selector switch complete all as specified and directed. |
| 63 | Supply & fixing PVC pipe 15mm dia suitable for desert coolers including taking out unserviceable PVC pipe complete all as specified and directed. |
| 64 | Supply & fixing cooler pad made out of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed. |
| 65 | Supply & fixing starting capacitor 4 MFD 230 volts including taking out unserviceable capacitor, including testing complete all as specified and directed. Make : Keil / Asian /Tesla. |
| 66 | S&F shutters made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/ hour including taking out unserviceable shutters complete all as specified and directed. |
| 67 | S&F bottom tank made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable bottom tank complete all as specified and directed. |
| 68 | S&F top cover made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable top cover complete all as specified and directed. |
| 69 | S&F side support made out of 18 SWG MS sheet suitable for desert cooler of capacity 4000/5000 Cum/hour including taking out unserviceable side supports complete all as specified and directed. |
| 70 | M&L for replacement of Fan blade aluminium type of desert cooler heavy duty HDPE suitable for 4000/5000 CFM cap complete all as directed by EIC. |
| 71 | Supply & fixing PVC copper conductor cable of size 1.50 Sqmm 3 core PVC sheathed suitable not less than 3 mtrs long with plug top 5 Amp suitable for desert cooler including taking down old unsv cable complete all as directed by ENgr-in-Charge. (Make FINOLEX/PARAGUN/POLYCAB). |
| 72 | M&L for dismantling voltage stabilizer of capaciti 5 KVA and re-winding to burn out linear coil of copper strip heavy cross sectional area, with insulating material in same gauge copper purity, no of turns in coil with varnishing, heating, testing etc with all other site work required to make the stabilizer serviceable including diagnosig its faulty parts and repairing/replacemetn of unserviceable parts of the same and complete including testing and commissioning and reassembling the same after repair. |
| 73 | Taking down old unsv Drain pipe and supply and fixing PVC drain type pipe suitable size for Split air conditioner complete all as specified and directed. |
| 74 | Taking down old unsv voltage stabilizer and supply and fixing wall mounted voltage stabilizer cap 5 KVA, input working range 170 V to 280 V, output working range 200 V to 240 V +- 5%, metal cabinet material, multifunctional digital display, Automatic low & high cut off, initial time delay, Auto start including wall mounting accessories complete all as specified and directed. Make-V Guard. |
| 75 | Taking down old unsv Desert cooler (exhaust fan motor 18\\" x 18\\") with fan blade and supply and fixing Desert cooler single phase heavy duty 450 mm sweep (exhaust fan motor 18\\" x 18\\"), copper winding, with fan blade and support leg suitable for 6000 CFM Desert Cooler complete with all connection accessories complete all as specified and directed. |
| 76 | Taking down old unsv remote control and supply and fixing remote controll as per existing original make and model complete all as specified and directed. |
| 77 | Supply and fix MCB four pole (Three pole and Neutral) 40 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed. |
| 78 | Supply and fix MCB four pole (Three pole and Neutral) 63 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed. |
| 79 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ Please Enable Macros to View BoQ information |