Tender For Repairs To Rain Water Intrusion/ D Ness, Rain Gutters And Downspouts Of Roof, Bituminous Membrane, Crumple Joints And Connected B/R Works At Waiting Room, Utl, Ltl, Htl, Sbm, Agm, Dbm And Various Other Otm Accn Of Nad Explosive And Non Exp
Tender Overview
Project Description
Tender for Repairs To Rain Water Intrusion/ D Ness, Rain Gutters And Downspouts Of Roof, Bituminous Membrane, Crumple Joints And Connected B/R Works At Waiting Room, Utl, Ltl, Htl, Sbm, Agm, Dbm And Various Other Otm Accn Of Nad Explosive And Non Explosive Area Under Age B/R-Ii At Naval Station Karanja
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Jun-2026 | Revised BOQ | BOQ | 03-Jul-2026 |
| 2 | 22-Jun-2026 | critical dates postponed | Date | 03-Jul-2026 |
| 3 | 16-Jun-2026 | Amendments of dates | Date | 29-Jun-2026 |
| 4 | 16-Jun-2026 | Amendments of dates | Date | 29-Jun-2026 |
| 5 | 03-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling AC (Corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and as directed.Notes for all items of BOQ:-(i) The rates quoted by the contractor shall be deemed to be of supply & erecting scaffoldings up to 30m height along with necessary fittings & fixtures for execution of the works and after working the scaffolding shall be removed and take away. Nothing extra shall be paid on this account.(ii) Floor surface area has to be cleaned after painting work, if contractor failed to cleaning the floor surface, a recovery @ Rs. 75/- per Sqm of floor area shall be made from his dues.(iii)The work pertains to water proofing shall be executed from authorized applicator of manufacturer of which the materials is proposed to be used by the contractor and approved by the Accepting Officer. |
| 2 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 3 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws complete all as specified and directed |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet to be used as crimp curve 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 5 | M&L 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L type or J type or cranked hook bolts complete all as specified and directed. |
| 6 | Complete Removal of existing water proofing treatment any description up to concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris upto 1500 m distance complete all as specified and directed NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work |
| 7 | Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete all as specified and directed |
| 8 | M&L for Providing, PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope including mixed with WPC by weight of total cement as per manufacturers instructions, complete all as specified and directedNote : WPC shall be measured and paid separately. |
| 9 | M&L for applying oil bound primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the prepared dry roof surface and provide and lay 4mm thick APP modifed water proofing membrane reinforced with non-wooven polyster matt with physical properties as given in particular specification. The laying shall got be done through authorized applicator of manufacturer as specified in particular specifications. Provide over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/sqm as prescribed by manufacturer of membrane including Ten years guarantee on prescribed form complete all as per particular specification , manufacturers instructions and as directed by Engineer-in-Charge. |
| 10 | M&L for rendering 10mm thick cement plaster in CM 1:3 on roof top surface including mixed with WPC by weight of total cement as per manufacturer's instructions complete all as specified and as directed.Note : WPC shall be measured and paid separately |
| 11 | Supply only liquid integral water proofing compound, complete all as specified and directed |
| 12 | Material and labour for cutting out cracks 'V' section on existing roofs or terrace cleaning out and filling solidly with a hot mixture bitumen and clean dry sand 1:1 by weight complete all as specified and directed by Engr-in-Charge. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 14 | M&L for roof trusses (framed) trussed, purlins, crane gantaries, rails and fastening and heavy braket framing (beam, tee, angle, chanel or flat section) including distance peices etc conforming to Fe 410 W Gde E-250 complete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed |
| 16 | Demolition of pre-cast concrete block masonary built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles complete all as specified and directed. |
| 17 | M&L for pre-cast cement concrete block masonry with solid blocks exceeding 10cm in width in PCC type B1, 1:2:4 (Using 20mm graded stone aggregate) and setting in mortar 1:6, complete all as specified and as directed |
| 18 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces with two coats i.e (10 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. Note:- Item rate shall be include any height of Bldgs for scafolding and all arrangement. |
| 19 | M&L for preparation of new or previously untreated plastered surfaces of walls / ceiling and applying two coats of acrylic antifungal paint exterior grade paint on one coat of primer complete all as specified and as directed. |
| 20 | M&L for preparation of new or previously untreated plastered surfaces of walls / Ceiling and applying two coats of acrylic antifungal paint exterior grade paint CAMOUFLAGE PATTERN on one coat of primer complete all as specified and as directed. |
| 21 | M & L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specified and directed. Note:- Item rate shall be include any height of building for scafolding and all arrangement. |
| 22 | Material and labour for preparation of new plastered surfaces of walls and appplying applying two coats of oil bound distemper over a coat of 1mm thick wall care putty on plastered surfaces complete all as specified and directed. |
| 23 | M&L for preparation of new or old external wall surface by wire brushing/grinding in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with mechanical water nozzal with clean water & allow to dry. Fill visible cracks/ joints by crack seal compound and epoxy base joint filler including resin and hardener in proportion as per maufactures instruction & allow to dry for 24 hours. Apply one coat of water base primer and allow to dry for 6 hours appx.Thereafter apply 02 coats of WB high build anti caronating coating cum waterproofing & match with brush at the interval of 08 hours between the coat and allow to dry to match the existing shade in camouflage pattern including or plain paint necessary scaffolding necessary security for the workers for any height, covering etc complete all as per specified and directed. Note:- Please note that external water proofing treatment on walls has to be carried out upto 30 meter height of the building, therefore quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at any building height. No additional payment shall be admissible on this account. |
| 24 | M&L Hacking out old broken glass ( any thickness, size, quality or description ) from wooden or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 25 | S&F 4 mm thick Sheet glass, ordinary quality, ground or obscured or frosted, on one side and glazing in wooden, Aluminium, steel frame in square of any size complete all as specified and directed. |
| 26 | S&F in repair 4 mm thick translucent white acrylic plastic sheet including fixing to wooden, Aluminium, steel frame in square of any size complete all as specified and directed. |
| 27 | S&F false ceiling with Armstrong XL 24mm grid system of grid size 600x600mm with 14mm thick ceiling board of RH-90. Grid shall be suspended from ceiling using 2mm dia pre straighten GI wire with 6mm nylon rawl plug & screws at 1200mm intervals complete all as manufacturers instructions and complete all as directed by Engr-in-Charge. |
| 28 | Supply and fix, in repair 8 to 10mm thick Armstrong ceiling board of RH -90 false ceiling consisting of 600mm x 600mm insert existing frame work without disturbing the other false ceiling and making good existing frame complete all as specified and directed by Engr-in-Charge. Note:- Item rate shall be include upto 30 meter of height of Bldgs for scafolding and all arrangement. |
| 29 | M&L for preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed. |
| 30 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends , swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed by Engr-in-Charge |
| 31 | S & F 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including bends etc. complete all as specified and directed. |
| 32 | S & F 3 mm thick UPVC valley gutter of bottom width not less than 200 mm and top width not less than 320 mm and height of not less than 200 mm with flow capacity of 52 Litres/ metre complete all as specified and directed by Engr-in-Charge. Make: Euro Guard or equivalent |
| 33 | S&F UPVC Clamp with GI Handle for fixing 320 mm UPVC Gutter with roof truss. Slope must be provided when installing the clamps to enable flow which locks the gutter inside the clip which prevents the edges from flipping out. GI Clamp must have minimum length of 45 cm of cross section of 32 mm x 8 mm and shall be fixed to UPVC Clamp using suitable screws complete all as specified and directed by Engr-in-ChargeMake: Euro Guard or equivalent |
| 34 | S&F CENTRE JOINT for joining 02 nos 320 mm UPVC Gutter and shall provide an edgy effect to the gutter. It shall also have a length of 140 mm and it shall be ensured the level of the gutter. It shall lock the gutter inside the clip which prevents the edges from flipping out using silicone sealant inside the slot first and then slide the gutter inside it complete all as specified and directed by Engr-in-ChargeMake: Euro Guard or equivalent |
| 35 | S&F CENTRE DROP fitting for 320 mm UPVC Gutter to outlet the water with a stopper with Outlet size of 160 mm (6 inches) round. It shall have a minimum length of 355 mm. It shall locks the gutter inside the clip which prevents the edges from flipping out Using silicone sealant inside the slot first and then slide the gutter inside it complete all as specified and directed by Engr-in-Charge |
| 36 | S&F END DROP fitting for 320 mm UPVC Gutter to outlet the water with a stopper with Outlet size of 160 mm (6 inches) round. It shall have a length of 305 mm. It shall locks the gutter inside the clip which prevents the edges from flipping out Using silicone sealant inside the slot first and then slide the gutter inside it complete all as specified and directed by Engr-in-Charge.Make: Euro Guard or equivalent Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender