| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed |
| 2 | Dismantling of timber scantlings 40 sq. cm and over in section, in any position unframed work, complete all as specified and directed. |
| 3 | Dismantling boarding any description fixed in ceiling etc in any position with nails, complete all as specified and directed. |
| 4 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 5 | Surface excavation n.exc 30 CM deep and getting out in soft /loose soil and removing excavated soil and depositing/levelling where directed at a level n.exc 1.5m above sthe starting poing, complete all as specified and directed |
| 6 | M&L for excavating in post holes each n exc 0.5cum in soft/loose soil, getting out and removing surplus soil to a distance n.exc 50 m and making good surface, complete all as specified and directed. |
| 7 | M&L for plain cement concrete 1:4:8, Type D2 ( using 40mm graded crushed stone aggregate) as in sub base of brick work, foundaion and mass concrte, complete all as specified and directed. |
| 8 | M&L for plain cement concrete 1:3:6, Type C2 ( using 40mm graded crushed stone aggregate) as in Post hole and mass concrete, complete all as specified and directed. |
| 9 | S&F roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc fixed in position,conforming to Fe-410(Gde 250), complete all as specified and as directed. |
| 10 | S&F mild steel work in plates (plain) channels, squares cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, complete all as specified and as directed. |
| 11 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed both ends each screwed end to be fitted with washers and one hexagonal square nut, n exc 30cm long dia of neck n exc12mm, complete all as specified and as directed. |
| 12 | M/L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 13 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self taping screws, complete all as specified and directed |
| 14 | S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed withslef tapping screws hook, complete all as specified and directed |
| 15 | S&F Plain galvanised mild steel sheeting , valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, 1mm thick including 40mm flat iron 4mm thick as in supporting and welded with steel frame etc., complete all as specified and directed |
| 16 | M&L for brick work with subclass 'B' bricks in CM 1:6, straight or curved on plan exc 6 m mean radius, complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed |
| 18 | M&L for rendering 10 mm thick in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed |
| 19 | Preparation of newly plastered wall surfaces by using necessary filling compound of Altek/Birla white 1mm thick wall care putty to obtain smooth/even surface using sand paper and applying two coats of oil bound dismater over a coat of primer, complete all as specified and directed |
| 20 | Material and labour for preparation of new surface externally of wall and applying 1 to 2mm wall care puty and Two or more coats of 100% Premium acrylic emulsion paint (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) without any brush marks on the surface in any colour over a coat of 2mm thick plaster of paris putty to make plastered surfaces even and smooth,complete all as specified and as directed. |
| 21 | S&F 12mm thick veneered decorative ply wood grade 1 (with BWR resins) with decorative face veneneers on one face with tinted white colour fixed with screws in ceiling,complete all as specified anddirected. |
| 22 | M&L 2nd class hard wood weather boarding desiner type on one edge as in eaves board etc and fixed with nails /screws including necessary scaffolding reqd to fix the same the edges of roof ) 25mm thick and rebated on thick edge to give 20mm laps and fixed on ceiling or any other position including dismantling of old boarding and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 23 | Providing and fixing Powder coated aluminium frames as in Doorn frame , window/Ventilator frame /Partition etc (minimum thickness of powder coating 50micron) work for, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed |
| 24 | S&F Powder coated of any colour (Thickness of powder coating not less than 50 micron ) Anodised aluminium window and ventilator shutters fixed/sliding/side Hung type without sash bar, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handle , locking arrangement, Necessary Butt Hinges, Tower Bolts etc., complete all as specifried and as directed. |
| 25 | S&F 5.5 mm thick sheet glass Plain/Tinted of selected quality and glazing with aluminium & rubber beading in squares/rectangular window panes etc with complete fittings and fixtures, complete all as specified and directed |
| 26 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples etc., complete all as specified and directed. |
| 27 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid dry and pointed, complete all as specified and directed. |
| 28 | M&L for plain cement concrete 1:2:4, type Bo (using 20 mm graded crushed stone aggregated) as in coping/ benching to manholes and drains including necessary form work, complete all as specified and directed. |
| 29 | M&L for plain cement concrete 1:2:4, type B2 (using 40 mm graded crushed stone aggregated) 100mm thick, as in sub base including necessary form work, complete all as specified and directed. |
| 30 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes including demolition/dismantling of old tiles and removal of debries, complete all as specified and directed. |
| 31 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, as in skirting, dados, walls, vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 10mm thick backing coat in cement motor 1:4 including dismantling old floor, hearth or wall tiling including cement mortar bedding (but not backing) etc., complete all as specified and directed. |
| 32 | M&L for plain cement concrete 1:2:4, type Bo (using 20 mm graded crushed stone aggregated) as in coping/ benching to manholes and drains including necessary form work, complete all as specified and directed. |
| 33 | M&L for taking down carefully existing old burnt out / unserviceable aluminium / copper point wiring system any type/ size and any description complete for light, fan,bell,socket, power points etc complete including removing the all type of fittings & fixture alongwith it connected fixing acessories such as all switches, sockets, ceiling roses, holder,regulators,bell etc complete and removing of all the old materials from the site for to taking as a schedule of credit complete all as specified and directed. |
| 34 | Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade, PVC Conduct FRLS conforming to IS - 694 multistranded Conceled with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and directed for the following :- |
| 35 | One light/ Bell point controlled by one, one way switch 5 amps, SP, complete all as specified and directed. |
| 36 | Supply and fixing MODULAR switch 1 way 6 A, 1 Module capacity 230 volts, complete all as specified and as directed. |
| 37 | Supply and fixing recessed/ceiling concealed/Surface mounted down lighter light fitting of round/Square flate shapes decorative type with high efficiency PMMA fiffuser soft glare free light with drivers & LED luminaire of rating capacity in 15Watt to 18Watt 220 volt AC complete light fitting set all as per existing fitting type/ size of sample /model and make and including making in cutting or additional extra corner cutting work on existing hole of ceiling surface (when if required at site) for setting & fixing of new light fitting complete including making in additional extra corner cutting work on existing hole of ceiling surface (when if required at site) for setting & fixing of new light fitting complete and also providing of suitable type of flate fexible two/three core cable and makong electric connection and including taking down of old existing fitting, complete all as specified and directed. |
| 38 | Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type of distribution board of rating SPN 8 way type 220 volt AC supply system and having neutral and earth link bus bar and mounting base chanel suitable for holding MCBs incommer and s outgoing system complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical and also refixing the electric meter and its wiring connection including taking down of existing meter and DBs, complete all as specified and directed. |
| 39 | Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type of distribution board of rating SPN 4/6 way type 220 volt AC supply system and having neutral and earth link bus bar and mounting base chanel suitable for holding MCBs incommer and s outgoing system complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical and also refixing the electric meter and its wiring connection including taking down of existing meter and DBs, complete all as specified and directed. |
| 40 | Supply and fixing of MCB SPN 40 to 63 Amps, 230 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity, complete all as specified and directed. |
| 41 | S&F MCB SP 6 to 32 Amps, 240 Volts, 50 Hz AC supply suitable for 'C' series, 10 KA breaking capacity, complete all as specified and directed. |
| 42 | Supply and fixing of Sub main wiring system with two runs PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size 2 Run of 1.5 Sqmm and 1 Run of 1.5Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI mark PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system complete and making good all disturbed surfaces match to the existing surface, complete all as specified and directed.Note: 3 runs of 1.5 Square mm copper cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 43 | Supply and fixing of Sub main wiring system with two runs PVC insulated FRLS wire,1100 volt grade with multistranded copper conductor wire of size 2 Run of 2.5 Sqmm and 1 Run of 2.5 Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy duty ISI mark PVC Casing capping / PVC conduit of suitable size along with its all fittings and connected accessories and duly fixed concealed on wall or surface on wall including taking down old unservicable sub main wiring system complete and making good all disturbed surfaces match to the existing surface complete all as specified and directed .Note: 3 runs of 2.5 Square mm copper cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 44 | M&L for earthing work complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level and connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of galvanised steel and to be protected by GI pipe 15 mm bore light grade & connected to earth test point/main switch board or main control board and also providing charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil all as shown in Electrical Plate No 3 of SSR part -I. and also making arrangment of 20 mm dia bore galvanised iron pipe (medium grade) for water and making funnel, wire mesh,and also including provision of concrete pit cover framing work in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and outer frame work of angle iron 25x25x6mm with top concrete pit cover and handle for lifting of cover complete work all as specified and directed . |
| 45 | Notes :-An amount of Rs 61,155.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |