Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Electric Division-III , JPDCL Jammu Name of Work: Fixing of Rate contract for Creation of 25 KVA 11/0.433 KV 3-Phase Distribution Sub Station (25 KVA Transformer, Energy Level: 2, \\"BIS Marked\\" , Aluminum Wound) ; 63 KVA 11/0.433 KV 3-Phase Distribution Sub Station (63 KVA Transformer, Energy Level: 2, \\"BIS Marked\\" , Aluminum Wound) and 100 KVA 11/0.433 KV 3-Phase Distribution Sub Station (100 KVA Transformer, Energy Level: 2, \\"BIS Marked\\" , Aluminum Wound);200 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, \\"BIS Marked\\" (Aluminium Wound and Copper Wound) ;250 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, \\"BIS Marked\\" ( Copper Wound) and 400 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, \\"BIS Marked\\" ( Copper Wound) by way of Supply, Erection , Testing and Commissioning on turnkey basis at different locations alongwith HT/LT under the jurisdiction of Electric Div-III Jammu during the financial Year 2026-27 or till Tender for FY 2027-28 is finalized. Contract No: e-NIT No. 18 of 2026-27 dt. 02.06.2026 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # |
| 2 | Item Description |
| 3 | Supply, Installation & commissioning of 11/0.433 KV, 25 KVA Aluminium Wound Distribution Transformer. |
| 4 | Supply, Installation & commissioning of 11/0.433 KV-25KVA, 50 Hz, Aluminiuim Wound Distribution Transformer of latest Energy level-2, (New), IS 1180 Part-I; 2014 as per latest upto Date Amendment. |
| 5 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 6 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 7 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 8 | Providing & Fixing of 50mm2 single core Cable. 1.1 Kv Grade, PVC Insulated Stranded Conductor FRLS Type. |
| 9 | Providing of 9Mtr Long Pole , ST-410 SP33 |
| 10 | Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 11 | Providing of GI Channel/Angel/Flat of sizes including clamps |
| 12 | Providing of Galvanized Nuts and Bolts |
| 13 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 14 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 15 | Providing of LT Distribution Box for 25KVa DTR with MCCB for incomer and SFU's for outgoing circuits. |
| 16 | Painting of Poles Red Oxide |
| 17 | Painting Of Poles Aluminium Paint |
| 18 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 19 | Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 20 | Providing & Fixing of Danger Plates with Clamps |
| 21 | Providing of GI Barbed wire for Anti Climbing |
| 22 | Supply, Installation & commissioning of 11/0.433 KV, 63 KVA Aluminium Wound Distribution Transformer. |
| 23 | Supply, Installation & commissioning of 11/0.433-63 KVA; 50 HZ, Aluminium woundDistribution transformer of latest energy efficiency level -2 ,(New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4Mtrs.suitable cable of ratings(Aluminium wound upto 200KVA, copper wound for 250KVA or higher KVA ratings). |
| 24 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 25 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 26 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 27 | Providing & Fixing of 70mm2 cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS Type. |
| 28 | Providing of 9Mtr Long Pole , ST-410 SP33 |
| 29 | Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 30 | Providing of GI Channel/Angel/Flat of sizes including clamps |
| 31 | Providing of Galvanized Nuts and Bolts |
| 32 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 33 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 34 | Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 35 | Providing of Wedge Connectors/PG Clamps |
| 36 | Providing & Fixing of Danger Plates with Clamps |
| 37 | Providing of GI Barbed wire for Anti Climbing |
| 38 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 39 | Painting of Poles Red Oxide |
| 40 | Painting Of Poles Aluminium Paint |
| 41 | Sundry items like Aluminuim Lugs, Jumpers, Binding tape |
| 42 | Providing of LT Distribution Box for 63KVa DTR with MCCB for incomer and SFU's for outgoing circuits. |
| 43 | Supply, Installation & commissioning of 11/0.433 KV, 100 KVA Aluminium Wound Distribution Transformer. |
| 44 | Supply, Installation & commissioning of 11/0.433-100KVA; 50 HZ, Aluminium woundDistribution transformer of latest energy efficiency level -2 ,(New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4Mtrs.suitable cable of ratings. |
| 45 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 46 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 47 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 48 | Providing & Fixing of 185 mm2 (2Ckt) cable, 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS Type. |
| 49 | Providing of 9Mtr Long Pole , ST-410 SP33 |
| 50 | Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 51 | Providing of GI Channel/Angel/Flat of sizes including clamps |
| 52 | Providing of Galvanized Nuts and Bolts |
| 53 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 54 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 55 | Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 56 | Providing of Wedge Connectors/PG Clamps |
| 57 | Providing & Fixing of Danger Plates with Clamps |
| 58 | Providing of GI Barbed wire for Anti Climbing |
| 59 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 60 | Painting of Poles Red Oxide |
| 61 | Painting Of Poles Aluminium Paint |
| 62 | Sundry items like Aluminuim Lugs, Jumpers, Binding tape |
| 63 | Providing of LT Distribution Box for 100KVa DTR with MCCB for incomer and SFU's for outgoing circuits. |
| 64 | Supply, Installation & commissioning of 11/0.433 KV, 250 KVA Copper wound Distribution Transformer. |
| 65 | Supply, Installation & commissioning of 11/0.433-250KVA; 50 HZ, Aluminium woundDistribution transformer of latest energy efficiency level -2 ,(New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4Mtrs.suitable cable of ratings(Aluminium wound upto 200KVA, copper wound for 250KVA or higher KVA ratings). |
| 66 | Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 67 | Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 68 | Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 69 | Providing & Fixing of 300mm2 1.1 KV Grade, PVC Insulated Stranded Conductor FRLS Type. |
| 70 | Providing of 9Mtr Long Pole , ST-410 SP33 |
| 71 | Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 72 | Providing of GI Channel/Angel/Flat of sizes including clamps |
| 73 | Providing of Galvanized Nuts and Bolts |
| 74 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 75 | Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 76 | Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete |
| 77 | Providing of Wedge Connectors/PG Clamps |
| 78 | Providing & Fixing of Danger Plates with Clamps |
| 79 | Providing of GI Barbed wire for Anti Climbing |
| 80 | Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole |
| 81 | Painting of Poles Red Oxide |
| 82 | Painting Of Poles Aluminium Paint |
| 83 | Sundry items like Aluminuim Lugs, Jumpers, Binding tape |
| 84 | Providing of LT Distribution Box for 250 KVa DTR with MCCB for incomer and SFU's for outgoing circuits. |
| 85 | Supply, Installation & commissioning of 11/0.433 KV, 400 KVA Copper wound Distribution Transformer. |
| 86 | 11/0.433 KV 400KVA;50Hz, Copper Wound Distribution Transformer oflatest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings. |
| 87 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 88 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 89 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 90 | 300mm²(2Ckt)/400mm² (2Ckt) Single Phase Cable,1.1K V Grade, PVCInsulated Stranded Conductor FRLS type |
| 91 | 9 Mtr. Long Pole( ST-410 SP33) |
| 92 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 93 | GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap |
| 94 | Galvanized Nuts and Bolts. |
| 95 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 96 | Transformer Pad/G.I Channel Bedding |
| 97 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 98 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 99 | Wedge Connectors / PG Clamps |
| 100 | Danger Plates with Clamps |
| 101 | GI Barbed Wire for Anti Climbing |
| 102 | 3-Ø, 4-Wire Trivector Meter with CT |
| 103 | Cement bottoming 1:2:4 mix as per REC standards .5cum /pole |
| 104 | Painting of Poles Red Oxide |
| 105 | Painting of Poles Aluminium Paint |
| 106 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 107 | Providing of LT Distribution Box for 400KVa DTR with MCCB for incomer and SFU's for outgoing circuits. |
| 108 | Laying of 11 KV Line 1.0 Km on PCC Pole 9.0 Mtr long using 30mm2 ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 109 | PCC Pole 9.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 110 | PCC Pole 11.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 111 | GI V Cross Arm with Top bracket including clamp |
| 112 | GI Channel X arm including clamps and braces. |
| 113 | 30mm2 ACSR Weasel |
| 114 | PG Clamps for 30 mm2 ACSR Weasel |
| 115 | 11kV Polymeric composite Pin Insulator 12kV,5kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 116 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 117 | Galvanised Nuts and Bolts |
| 118 | Danger Plates with Clamps |
| 119 | Anti Climbing device with Clamps |
| 120 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 121 | Stone Pad 300 mmx300mmx75mm |
| 122 | Aluminium Jointing sleeves |
| 123 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia stranded wire complete |
| 124 | Laying of 11 KV Line 1.0 Km on Steel Tubular Pole 9.0 Mtr long using ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 125 | Steel Tubular Pole 9.0 Mtr long (ST-410 SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 126 | Steel Tubular Pole 11.0 Mtr long (ST-410 SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 127 | GI V Cross Arm with Top bracket including clamp |
| 128 | GiI Channel X arm including clamps and braces. |
| 129 | 30mm2 ACSR Weasel |
| 130 | PG Clamps for 30 mm2 ACSR Weasel |
| 131 | 11kV Polymeric composite Pin Insulator 12kV,5kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 132 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 133 | Galvanised Nuts and Bolts |
| 134 | Danger Plates with Clamps |
| 135 | Anti Climbing device with Clamps |
| 136 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 137 | Red Oxide |
| 138 | Aluminuim Paint |
| 139 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/Pole |
| 140 | Aluminium Jointing sleeves |
| 141 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia stranded wire complete |
| 142 | Laying of 11 KV Line 1.0 Km on PCC Pole 9.0 Mtr long using 50mm2 ACSR Rabbit (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 143 | PCC Pole 9.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 144 | PCC Pole 11.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 145 | GI V Cross Arm with Top bracket including clamp |
| 146 | GiI Channel X arm including clamps and braces. |
| 147 | 50mm 2 ACSR Rabbit |
| 148 | PG Clamps for 50mm 2 ACSR Rabbit |
| 149 | 11kV Polymeric composite Pin Insulator 12kV,5kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 150 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 151 | Galvanised Nuts and Bolts |
| 152 | Danger Plates with Clamps |
| 153 | Anti Climbing device with Clamps |
| 154 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 155 | Stone Pad 300 mmx300mmx75mm |
| 156 | Aluminium Jointing sleeves |
| 157 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia stranded wire complete |
| 158 | Laying of 11 KV Line 1.0 Km on Steel Tubular Pole 9.0 Mtr long using 50mm2 ACSR Rabbit (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 159 | Steel Tubular Pole 9.0 Mtr long (ST-410 SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 160 | Steel Tubular Pole 11.0 Mtr long (ST-410 SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 161 | GI V Cross Arm with Top bracket including clamp |
| 162 | GiI Channel X arm including clamps and braces. |
| 163 | 50mm 2 ACSR Rabbit |
| 164 | PG Clamps for 50mm 2 ACSR Rabbitl |
| 165 | 11kV Polymeric composite Pin Insulator 12kV,5kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 166 | 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm |
| 167 | Galvanised Nuts nad Bolts |
| 168 | Danger Plates with Clamps |
| 169 | Anti Climbing device with Clamps |
| 170 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 171 | Red Oxide |
| 172 | Aluminuim Paint |
| 173 | Cement Bottoming 1:2:4 mix as per REC Standards 5cum/Pole |
| 174 | Aluminium Jointing sleeves |
| 175 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia stranded wire complete |
| 176 | Laying of 1 Kms of 11kV XLPE, Single circuit 3 core 185mm2 Aluminium round wire armoured cable on 9mtr PCC Pole. (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 177 | 9 Mtr. Long Pole(PCC WL-300Kg) |
| 178 | 11 kV, three core, 185 mm2 Aluminium round wire Armoured XLPE Cable , FRLS |
| 179 | Heat Shrinkable Outdoor Cable Termination Kit |
| 180 | Suspension Clamp with eye hook |
| 181 | Tension Clamp with eye hook |
| 182 | Galvanized Nuts and Bolts |
| 183 | Danger Plates |
| 184 | Anti-Climbing Device with Clamps |
| 185 | Earthing Complete by GI Rod 20mm 2.5 mtrlong through GI Strip. |
| 186 | Stone Pad (300 mm x 300 mm x 75 mm) |
| 187 | Mid Span Straight Through Jointing Kit for 11 kV ABC |
| 188 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 189 | Laying of 1 Kms of 11kV XLPE, Single circuit 3 core240mm2 Aluminium round wire armoured cable on 9mtr PCC Pole. (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 190 | 9 Mtr. Long Pole(PCC WL-300Kg ) |
| 191 | 11 kV , three core 240 mm2 Aluminium round wire Armoured XLPE Cable, FRLS |
| 192 | Heat Shrinkable Outdoor Cable Termination Kit |
| 193 | SuspensionClamp with eye hook |
| 194 | Tension Clamp with eye hook |
| 195 | Galvanized Nuts and Bolts |
| 196 | Danger Plates |
| 197 | Anti-Climbing Device with Clamps |
| 198 | Earthing Complete by GI Rod 20mm 2.5 mtrlong through GI Strip. |
| 199 | Stone Pad (300 mm x 300 mm x 75 mm) |
| 200 | Mid Span Straight Through Jointing Kit for 11 kV ABC |
| 201 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 202 | Laying of 1 Kms of 11kV XLPE, Single circuit 3 core 185mm2 Aluminium round wire armoured cable on 9mtr ST Pole. (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 203 | 9 Mtr. Long Pole( ST-410 SP33) |
| 204 | 11 kV,three core, 185 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (One spare cable) |
| 205 | Heat Shrinkable Outdoor Cable Termination Kit |
| 206 | Suspension Clamp with eye hook |
| 207 | Tension Clamp with eye hook |
| 208 | Galvanized Nuts and Bolts |
| 209 | Danger Plates |
| 210 | Anti-Climbing Device with Clamps |
| 211 | Earthing Complete by GI Rod 20mm 2.5 mtrlong through GI Strip. |
| 212 | Red Oxide |
| 213 | Aluminium Paint |
| 214 | Cement bottoming 1:2:4 mix as per REC standards .45cum /pole |
| 215 | Mid Span Straight Through Jointing Kit for 11 kV ABC |
| 216 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 217 | Laying of 1 Kms of 11kV XLPE, Single circuit 3 core240mm2 Aluminium round wire armoured cable on 9mtr ST Pole. (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 218 | 9 Mtr. Long Pole( ST-410 SP33) |
| 219 | 11 kV , three core 240 mm2 Aluminium round wire Armoured XLPE Cable, FRLS |
| 220 | Heat Shrinkable Outdoor Cable Termination Kit |
| 221 | Suspension Clamp with eye hook |
| 222 | Tension Clamp with eye hook |
| 223 | Galvanized Nuts and Bolts |
| 224 | Danger Plates |
| 225 | Anti-Climbing Device with Clamps |
| 226 | Earthing Complete by GI Rod 20mm 2.5 mtrlong through GI Strip. |
| 227 | Red Oxide |
| 228 | Aluminium Paint |
| 229 | Cement bottoming 1:2:4 mix as per REC standards .45cum /pole |
| 230 | Mid Span Straight Through Jointing Kit for 11 kV ABC |
| 231 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 232 | Laying of LT Line (3-Phase, 4-Wire) 1.0 Km on ST Poles 8.0 Mtr long using ACSR Weasel (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 233 | ST Pole 8.0 Mtr long (ST 410 SP15) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 234 | ST Pole 9.0 Mtr long (ST 410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 235 | GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) for Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts |
| 236 | 30mm2 ACSR weasel |
| 237 | 16KN Polymer /Poreclain Shackle Insulators |
| 238 | Galvanised Nuts and bolts |
| 239 | Danger Plates with Clamps |
| 240 | Anti Climbing device with Clamps |
| 241 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 242 | Red Oxide |
| 243 | Aluminium Paint |
| 244 | Cement Bottoming 1:2:4Mix as per REC Standards 45CUm/pole |
| 245 | Aluminium Jointing sleeves |
| 246 | LT Line Spacers (3-Phase, 4-Wire) |
| 247 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete |
| 248 | Laying of LT Line (3-Phase, 4-Wire) 1.0 Km on PCC Poles 8.0 Mtr long using 50mm2 ACSR Rabbit(Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 249 | PCC Pole 8.0 Mtr long (WL 200 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 250 | PCC Pole 9.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 251 | GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) for Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts |
| 252 | 50mm2 ACSR Rabbit |
| 253 | 16KN Polymer / Poreclain Shackle Insulators |
| 254 | Galvanised Nuts and bolts |
| 255 | Danger Plates with Clamps |
| 256 | Anti Climbing device with Clamps |
| 257 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 258 | Stone Pad 300 mmx300mmx75mm |
| 259 | Aluminium Jointing sleeves |
| 260 | LT Line Spacers (3-Phase, 4-Wire) |
| 261 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete |
| 262 | Laying of LT Line (3-Phase, 4-Wire) 1.0 Km on ST Poles 8.0 Mtr long using ACSR Rabbit (Supplying including Transportation , Erection, Testing & Commissioning Comp. Job) |
| 263 | ST Pole 8.0 Mtr long (ST 410 SP15) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 264 | ST Pole 9.0 Mtr long (ST 410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 265 | GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) for Shackle Insulator along with Nut & Bolt of sorts |
| 266 | 50mm2 ACSR weasel |
| 267 | 16KN Polymer / Porcelain Shackle Insulators |
| 268 | Galvanised Nuts and bolts |
| 269 | Danger Plates with Clamps |
| 270 | Anti Climbing device with Clamps |
| 271 | Earthing Complete by GI Rod 20 mm, 2.5 Mtr Long through GI Strip |
| 272 | Red Oxide |
| 273 | Aluminium Paint |
| 274 | Cement Bottoming 1:2:4Mix as per REC Standards 45CUm/pole |
| 275 | Aluminium Jointing sleeves |
| 276 | LT Line Spacers (3-Phase, 4-Wire) |
| 277 | Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete |
| 278 | (Erection of 1KM LT Line on 8mtr PCC Pole with 70mm2 ABC Cable ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 279 | 8mtr Long Pole (PCC WL-200Kg) |
| 280 | 9mtr Long Pole (PCC WL-300Kg) |
| 281 | 70 mm2 AB (LT) Cable (3x70+1x16+1x50 mm2)XLPE (1.1 kv,3+1 C,Al) |
| 282 | Suspension Clamp with eye hook |
| 283 | Tension Clamp with eye hook |
| 284 | Straight Through Cable Jointing Kit |
| 285 | Galavnized Nuts and Bolts |
| 286 | Danger Plates |
| 287 | Anti Climbing Device with Clamps |
| 288 | Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip |
| 289 | Stone Pad (300mmx300mmx75mm) |
| 290 | Insulating Piercing Connectors |
| 291 | PG Clamps |
| 292 | Galavnised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm) nut bolts, 2 Nos. Turn buckles, 1.8m long, 16mm diameter solid GS Stay rod and 7/3.15 mm dia GI Stranded wire complete |
| 293 | (Erection of 1KM LT Line on 8mtr PCC Pole with 120mm2 ABC Cable ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 294 | 8mtr Long Pole (PCC WL-200Kg) |
| 295 | 9mtr Long Pole (PCC WL-300Kg) |
| 296 | 120 mm2 AB (LT) Cable (3x120+1x16+1x70 mm2)XLPE (1.1 kv,3+1 C,Al) |
| 297 | Tension Clamp with eye hook |
| 298 | Suspension Clamp with eye hook |
| 299 | Straight Through Cable Jointing Kit |
| 300 | Galavnized Nuts and Bolts |
| 301 | Danger Plates |
| 302 | Anti Climbing Device with Clamps |
| 303 | Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip |
| 304 | Stone Pad (300mmx300mmx75mm) |
| 305 | Insulating Piercing Connectors |
| 306 | PG Clamps |
| 307 | Galavnised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm) nut bolts, 2 Nos. Turn buckles, 1.8m long, 16mm diameter solid GS Stay rod and 7/3.15 mm dia GI Stranded wire complete |
| 308 | (Erection of 1KM LT Line on 8mtr ST Pole with 70mm2 ABC Cable ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 309 | 8mtr Long Pole (ST-410 SP15) |
| 310 | 9mtr Long Pole (ST-410 SP33) |
| 311 | 70 mm2 AB (LT) Cable (3x70+1x16+1x50 mm2)XLPE (1.1 kv,3+1 C,Al) |
| 312 | Suspension Clamp with eye hook |
| 313 | Tension Clamp with eye hook |
| 314 | Straight Through Cable Jointing Kit |
| 315 | Galavnized Nuts and Bolts |
| 316 | Danger Plates |
| 317 | Anti Climbing Device with Clamps |
| 318 | Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip |
| 319 | Red Oxide |
| 320 | Aluminium Paint |
| 321 | Cement Bottoming 1:2:4 mix as per REC Standards 45cum/pole |
| 322 | Insulating Piercing Connectors |
| 323 | PG Clamps |
| 324 | Galavnised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm) nut bolts, 2 Nos. Turn buckles, 1.8m long, 16mm diameter solid GS Stay rod and 7/3.15 mm dia GI Stranded wire complete |
| 325 | (Erection of 1KM LT Line on 8mtr ST Pole with 120mm2 ABC Cable ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 326 | 8mtr Long Pole (ST-410 SP15) |
| 327 | 9mtr Long Pole (ST-410 SP33) |
| 328 | 120 mm2 AB (LT) Cable (3x120+1x16+1x70 mm2)XLPE (1.1 kv,3+1 C,Al) |
| 329 | Suspension Clamp with eye hook |
| 330 | Tension Clamp with eye hook |
| 331 | Straight Through Cable Jointing Kit |
| 332 | Galavnized Nuts and Bolts |
| 333 | Danger Plates |
| 334 | Anti Climbing Device with Clamps |
| 335 | Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip |
| 336 | Red Oxide |
| 337 | Aluminium Paint |
| 338 | Cement Bottoming 1:2:4 mix as per REC Standards 45cum/pole |
| 339 | Insulating Piercing Connectors |
| 340 | PG Clamps |
| 341 | Galavnised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm) nut bolts, 2 Nos. Turn buckles, 1.8m long, 16mm diameter solid GS Stay rod and 7/3.15 mm dia GI Stranded wire complete |
| 342 | (Erection of 1KM LT Line on 8mtr PCC Pole with 50mm2 AB Cable ) Providing/Supplying, Erection/Installation, Testing & commissioning comp Job) |
| 343 | 8mtr Long Pole (PCC WL-200Kg) |
| 344 | 9mtr Long Pole (PCC WL-300Kg) |
| 345 | 50 mm2 AB (LT) Cable (3x50+1x16+1x35 mm2)XLPE (1.1 kv,3+1 C,Al) |
| 346 | Suspension Clamp with eye hook |
| 347 | Tension Clamp with eye hook |
| 348 | Straight Through Cable Jointing Kit |
| 349 | Galavnized Nuts and Bolts |
| 350 | Danger Plates |
| 351 | Anti Climbing Device with Clamps |
| 352 | Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip |
| 353 | Stone Pad (300mmx300mmx75mm) |
| 354 | Insulating Piercing Connectors |
| 355 | PG Clamps |
| 356 | Galavnised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x200x6mm) nut bolts, 2 Nos. Turn buckles, 1.8m long, 16mm diameter solid GS Stay rod and 7/3.15 mm dia GI Stranded wire complete Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 No Quoted Rate in Figures Item330 Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information Compatibility Report for BOQe-NIT68.xls Run on 05-03-2024 17:31 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 Excel 97-2003 Some cells in this workbook contain data validation rules, which refer to values on other worksheets. These rules won't be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 4.0 Excel 97-2003 PCC Pole 9.0 Mtr long (WL 300 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Item73 19.0 3.8 GI V Cross Arm with Top bracket including clamp Item75 289.0 57.8 GiI Channel X arm including clamps and braces. Item76 160.0 32.0 30mm 2 ACSR Weasel Item77 3.09 0.618 PG Clamps for 30 mm2 ACSR Weasel Item78 12.0 3.0 11kV Polymeric composite Pin Insulator 12kV,5kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm Item79 57.0 12.0 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm Item80 12.0 2.4 Galvanised Nuts nad Bolts Item81 21.0 4.2 Danger Plates with Clamps Item82 21.0 4.2 Anti Climbing device with Clamps Item83 21.0 4.2 Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip Item84 21.0 4.2 Stone Pad 300 mmx300mmx75mm Item85 21.0 4.2 Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia stranded wire complete Item87 5.0 1.0 PCC Pole 8.0 Mtr long (WL 200 Kg) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Item137 19.0 3.8 GI U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) for Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts Item139 84.0 16.0 30mm2 ACSR weasel Item140 4.12 0.8 16KN Polymer/ Porcelain Shackle Insulators Item141 84.0 16.0 Galvanised Nuts and bolts Item142 21.0 4.2 Danger Plates with Clamps Item143 21.0 4.2 Anti Climbing device with Clamps Item144 21.0 4.2 Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip Item145 21.0 4.2 Stone Pad 300 mmx300mmx75mm Item146 21.0 4.2 Aluminium Jointing sleeves Item147 4.0 1.0 LT Line Spacers (3-Phase, 4-Wire) Item148 20.0 4.0 Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete Item149 5.0 1.0 |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy