| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: EXECUTIVE ENGINEER, MECHANICAL &-HOSPITAL DIVISION , JAMMU Supply, Installation, Testing and Commissioning (SITC) of 2 Ton Split Air Conditioners (HOT and COLD) in OPD Room No. 6 of the Obstetrics & Gynaecology Department along with Allied works at Govt. SMGS Hospital, Jammu MHDJ/e-NIT 61 of 2026-27 Dated: 02.06.2026 Due : 08.06.2026 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. 0.0 Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATES INCLUSIVE ALL TAXES Excise Duty GST Rs. P Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 54 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=580 cfm in Rooms of Anesthesia Department with minimum 3 star and of reputed make along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. |
| 3 | SITC of Wall mounted stabilizer (AVR) for 02 TR Air conditioners of capacity 5 KVA (input voltage range 90 volts-300 volts) of reputed Make conforming to relevant IS/BIS norms and standards having High Voltage Cut-off (HVC), Low Voltage Cut-off (LVC), Overload Protection, Short Circuit Protection, Surge / Spike Protection, Time Delay Protection and Thermal Protection along with allied accessories complete for installation and commissioning. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. |
| 4 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard makes i.e. Havells, Polycab, Finolex, Anchor only conforming to relevant IS/BIS norms and standards for the purpose of connecting air conditioning unit to the electrical power connection via stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. |
| 5 | Providing and laying of extra FRLS PVC insulated 2.5 sq mm 4 core communication cable ISI Marked (using conduits and wire fasteners / cable clips/ conduit fasteners) of reputed make i.e. Havells, Polycab, Finolex, Anchor only conforming to relevant IS/BIS norms and standards for the purpose of connecting air conditioning indoor unit to the installed air conditioning outdoor units, as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes. |
| 6 | Providing and fitting of 32A C-curve SPN MCB pre-fitted in a durable metal gang box enclosure for 2 TR Capacity Air conditioners with of standard make i.e. Havells, L&T, Schneider, Siemens only conforming to relevant IS/BIS norms and standards (complete with fittings). Complete job as per site requirement and instructions of Engineer-in-charge and includes cost of materials (including clamps, insulation, etc.), labour charges, transportation charges and all other charges and taxes. |
| 7 | Providing and laying of PVC drain pipe of size viz. ¾” to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes. |
| 8 | Providing and fitting of extra refrigerant copper pipes viz. 3/8” & 5/8” (one for discharge & second for suction) etc. with proper Insulation conforming to relevant norms and standards. The Cu refrigerant pipes will be installed with appropriate size bends, threaded/brazed joints and clamps as per site requirement to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass pipes with insulation, plastering & refinishing of the same to the original finish as per the site requirements. Complete job must be as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and taxes. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |