| 1 | Earth work in excavation in ordinary soil in all type of foundation trenches including dressing of the side and ramming of bottom. Lifts upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m. All kinds of soil. (MORTH/A.R./YEIDA/Based on UPPWD/SOR-2020)) Depth from 0.0 to 1.5 M below G.L. |
| 2 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from 'the site of work and including watering, dressing etc. labour and T&P etc. required for the proper complition of the work. saplings of girth upto 30 cms. measured at a height of 1 M. above ground level and removal of rubbish upto a of cleared.50 M. out side the periphery of area distance (UPPWD/SOR-2020/255) |
| 3 | Cement concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, tools & plants etc. required for proper completion of the work. (UPPWD/SOR-2020/281) |
| 4 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more./Cold twisted bars. (DAR/5.22.6/Based on UPPWD/SOR-2020)) |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. “(Note:- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level. (DAR/5.33.1/Based on UPPWD/SOR-2020)) |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. “(Note:- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete. (DAR/5.9.1/Based on UPPWD/SOR-2020)) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DAR/5.9.5/Based on UPPWD/SOR-2020)) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts.(DAR/5.9.7/Based on UPPWD/SOR-2020)) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform (DAR/5.9.3/Based on UPPWD/SOR-2020)) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slab and breaks in floor and walls under 20cms wide (DAR/5.9.16.1/Based on UPPWD/SOR-2020) |
| 13 | M-150 brick work in 1:4 one cement and four coarse sand 2.20 F.M. mortar in foundation and plinth including supply of all material, labour, T&P etc. required for proper completion of the work. (UPPWD/SOR-2020/305(a) |
| 14 | M-150 brick work in 1:4 one cement and four coarse sand mortar n superstructure including necessary Cutting & moulding of brick as required thickness of walls not to be less than one brick. including supply of all material, labour, T&P etc. required for proper completion of the work. i Add extra labour to above items. (UPPWD/SOR-2020/309) |
| 15 | 12mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand) (DAR/13.4.2/Based on UPPWD/SOR-2020) |
| 16 | 15mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand) (DAR/13.5.2/Based on UPPWD/SOR-2020) |
| 17 | 6mm cement plaster of mix: 1:3 (1 cement : 3 fine sand) (DAR/13.16.1/Based on UPPWD/SOR-2020)) |
| 18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DAR/8.31/Based on UPPWD/SOR-2020)) |
| 19 | Providing and laying ceramic glazed floor tiles 300x300mm by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm (DAR/11.41.2/Based on UPPWD/SOR-2020)) |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30mm thick including ISI marked stainless steel butt hinges with necessary screws. (DAR/9.21.2/Based on UPPWD/SOR-2020)) |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DAR/10.25.2/Based on UPPWD/SOR-2020)) |
| 22 | Renewing panes of glass in door, window & ventilators or fixing in the new work with 3mm thick glass panes fixed |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm (DAR/11.41.2/Based on UPPWD/SOR-2020)) |
| 24 | Making Khurra 45 cms x 45 cms with c.c. 1 : 2 : 4 average 5 cms thick including supply of all materials, labour, T and P etc. required for proper completion of work. (UPPWD/SOR-2020/New Items/P-28) |
| 25 | Providing and fixing upvc pipe (6.0 kg per sqcm pressure) kissan/supreme quality or equivalent) including jointing of pipes & fitting 100mm diameter |
| 26 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete |
| 27 | Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (but for every coat after the first coat).(UPPWD/SOR-2020/649+650) |
| 28 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. (DAR/13.45.1/Based on UPPWD/SOR-2020)) |
| 29 | Supply and fixing of RCC Grill work (JALI) of approved pattern & make at site of work in cement concrete consisting of cement, approved coarse sand and 6mm nominal size stone grit In the propotion od 1:2:4 & reinforcement with 6 mm dia M.S. wire |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. (DAR/13.61.1/Based on UPPWD/SOR-2020) |
| 31 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with waterproofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d)Finishing the surface with 20 mm thick joint less cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120mm and minimum thickness at khurra as 65 mm. (DAR/22.7.1/Based on UPPWD/SOR-2020)) |
| 32 | Construction of Granular Sub-Base by providing close graded material, mixing in mechanical mix plant at OMC, carriage of mixed material to work at site, spreading uniform layers with motor grader on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 for Grade-1 material. (MORTH/(AR/YEIDA/Based on UPPWD/SOR-2020) |
| 33 | Supply & Fixing of india mark hand pump including making chabutara of dia 2mtr and 45 mtr lowering (depth) and PVC pipe etc. (pressure 6.0kg/cmsqr) |
| 34 | Providing and laying 60mm thick I.S.I. mark factory made cement concrete interlocking concrete paver block made by block making machine with strong vibratory compaction of approved size, design, shape, laid in required colour and pattern over and including average 50mm thick compacted bed coarse sand and filling the joints with fine sand all complete as per the direction of Engineer-in-charge with conforming to IS-15658 and IRC:SP:63. (AR/YEIDA/ Based on UPPWD/SOR-2020) |
| 35 | Providing and Fixinf and Commisoining of single Phasesubmersible pump set in existing Bore well suitable 45 LPM Discharge 25 mtr to 70 mtr head minimum two star rating of approved make PVC cable supportwise starter etc complete in all respect including cost of dismentaling of exisiting handpump achine complete |
| 36 | Providing and fixing upvc pipe (6.0 kg per sqcm pressure) kissan/supreme quality or equivalent) including jointing of pipes & fitting 100mm diameter |
| 37 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DAR/18.48/Based on UPPWD/SOR-2020)) |
| 38 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DAR/17.1.1/Based on UPPWD/SOR-2020)) |
| 39 | Providing and fixing wash basin with CI brackets 15mm CP brass pillar taps 32 mm CP brass waste of standards pattern, including painting of fitting and brackets, cutting 630x450mm Please Enable Macros to View BoQ information |